The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optimal placement of distributed energy storage systems in distribution networks using artificial bee colony algorithm
Open accessAbstract
The deployment of utility-scale energy storage systems (ESSs) can be a significant avenue for improving the performance of distribution networks. An optimally placed ESS can reduce power losses and line loading, mitigate peak network demand, improve voltage profile, and in some cases contribute to the network fault level diagnosis. This paper proposes a strategy for optimal placement of distributed ESSs in distribution networks to minimize voltage deviation, line loading, and power losses. The optimal placement of distributed ESSs is investigated in a medium voltage IEEE-33 bus distribution system, which is influenced by a high penetration of renewable (solar and wind) distributed generation, for two scenarios: (1) with a uniform ESS size and (2) with non-uniform ESS sizes. System models for the proposed implementations are developed, analyzed, and tested using DIgSILENT PowerFactory. The artificial bee colony optimization approach is employed to optimize the objective function parameters through a Python script automating simulation events in PowerFactory. The optimization results, obtained from the artificial bee colony approach, are also compared with the use of a particle swarm optimization algorithm. The simulation results suggest that the proposed ESS placement approach can successfully achieve the objectives of voltage profile improvement, line loading minimization, and power loss reduction, and thereby significantly improve distribution network performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.09.081 · Cited by 3,869
Jayasekara, N., Masoum, M. A. S., & Wolfs, P. J. (2016) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2015.2487360 · Cited by 260 · cited 9×
“However, in [12, 42, 44, 46] ESS name is mentioned as battery ESS (BESS) rather than specifying the ESS technology, e.g., lead-acid, Li-ion or other.”
InfluentialA multi-agent solution to distribution system management by considering distributed generators
Ren, F., Zhang, M., & Sutanto, D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2223490 · Cited by 91
Cited by
Adefarati, T., & Bansal, R. C. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.050 · Cited by 447
Recent development of membrane for vanadium redox flow battery applications: A review
Shi, Y., Eze, C., Xiong, B., He, W., Zhang, H., Lim, T. M., Ukil, A., & Zhao, J. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.087 · Cited by 423
Koçak, B., Fernandez, A. I., & Paksoy, H. (2020) · Solar Energy · doi:10.1016/j.solener.2020.08.081 · Cited by 416
Prabawa, P., & Choi, D.-H. (2021) · IEEE Access · doi:10.1109/access.2021.3109621 · Cited by 31
Metadata
- Authors
- Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 232
- Pages
- 212-228
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W2894905641
- Cited by
- 210
- References
- 3
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal placement of distributed energy storage systems in distribution networks using artificial bee colony algorithm. https://app.cochat.ai/papers/10.1016/j.apenergy.2018.07.100
- The paper
- Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018). Optimal placement of distributed energy storage systems in distribution networks using artificial bee colony algorithm. Applied Energy. https://doi.org/10.1016/j.apenergy.2018.07.100
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.