A review of power consumption models of servers in data centers
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
This study provides an overview of power consumption models of servers in data centers. The server is the basic unit of both power and heat flow paths; therefore, its power consumption model can be used for both energy management and thermal management. Investigations of server power trends were carried out according to the data from the Standard Performance Evaluation Corporation (SPEC). It is found that a heavier workload can be handled without consuming more energy, and the difference between the peak power and idle power of the servers is not consistent from generation to generation. Furthermore, the existing power consumption models are categorized as additive models, baseline power + active power (BA) models, and other models based on calculation formula and other factors. Specifically, there are four forms of BA models: linear regression models, power function models, non-linear models and polynomial models. Besides, these models have been compared in terms of accuracy. It can be found that the polynomial model and the linear regression model perform better in terms of accuracy. Additionally, the model applications are summarized. Considering server architecture upgrades and technological innovation, the establishment of the new model and its application scenarios are discussed. Moreover, in-depth and accurate power consumption models must be extensively researched and applied to effectively improve data centers, including information technology (IT) equipment and cooling equipment, in terms of overall energy performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beloglazov, A., Abawajy, J., & Buyya, R. (2012) · Future Generation Computer Systems · doi:10.1016/j.future.2011.04.017 · Cited by 2,761
Power provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797
Data Center Energy Consumption Modeling: A Survey
Dayarathna, M., Wen, Y., & Fan, R. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2481183 · Cited by 1,165
United States Data Center Energy Usage Report
Lawrence Berkeley National Laboratory (LBNL), B., Shehabi, A., USDOE, Smith, S., Sartor, D., Brown, R., Herrlin, M., Koomey, J., Masanet, E., Horner, N., et al. (2016) · doi:10.2172/1372902 · Cited by 1,040
A Taxonomy and Survey of Energy-Efficient Data Centers and Cloud Computing Systems
Beloglazov, A., Buyya, R., Lee, Y. C., & Zomaya, A. (2011) · Advances in Computers · doi:10.1016/b978-0-12-385512-1.00003-7 · Cited by 777
Concurrency and Computation: Practice and Experience
(2006) · Concurrency and Computation Practice and Experience · doi:10.1002/(issn)1532-0634 · Cited by 738
Energy-aware server provisioning and load dispatching for connection-intensive internet services
Gong, C., He, W., Liu, J., Nath, S., Rigas, L., Xiao, L., & Zhao, F. (2008) · Cited by 654
Virtual machine power metering and provisioning
Kansal, A., Zhao, F., Liu, J., Kothari, N., & Bhattacharya, A. A. (2010) · Proceedings of the 1st ACM symposium on Cloud computing · doi:10.1145/1807128.1807136 · Cited by 556
Managing server energy and operational costs in hosting centers
Chen, Y., Das, A., Qin, W., Sivasubramaniam, A., Wang, Q., & Gautam, N. (2005) · Proceedings of the 2005 ACM SIGMETRICS international conference on Measurement and modeling of computer systems · doi:10.1145/1064212.1064253 · Cited by 556
Full-System Power Analysis and Modeling for Server Environments
Economou, D., Rivoire, S., Kozyrakis, C., & Ranganathan, P. (2006) · CSUN ScholarWorks (California State University, Northridge) · Cited by 399
Cited by
Zhu, H., Zhang, D., Goh, H. H., Wang, S., Ahmad, T., Mao, D., Liu, T., Zhao, H., & Wu, T. (2023) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.104322 · Cited by 164
Water-energy tradeoffs in data centers: A case study in hot-arid climates
Karimi, L., Yacuel, L., Johnson, J. D., Ashby, J., Green, M., Renner, M., Bergman, A., Norwood, R., & Hickenbottom, K. L. (2022) · Resources Conservation and Recycling · doi:10.1016/j.resconrec.2022.106194 · Cited by 43
Słoniec, J., Kulisz, M., Małecka-Dobrogowska, M., Konurbayeva, Z., & Sobaszek, Ł. (2025) · Energies · doi:10.3390/en18215573 · Cited by 9
Parsafar, P. (2025) · The Journal of Supercomputing · doi:10.1007/s11227-024-06510-1 · Cited by 9
“Traditional performance metrics, while valuable, often lack the clarity needed to convey key findings consistently [29] as they mostly identify the CPU as the most decisive component [15, 16, 30].”
Metadata
- Authors
- Jin, C., Bai, X., Yang, C., Mao, W., & Xu, X.
- Venue
- Applied Energy
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 265
- Pages
- 114806
- ISSN
- 0306-2619 (ISSN-L)
- OpenAlex
- W3015015599
- Cited by
- 229
- References
- 76
- FWCI
- 20.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.