CoChat

Optimal PV-EV sizing at solar powered workplace charging stations with smart charging schemes considering self-consumption and self-sufficiency balance

Open access
Fachrizal, Reza, Shepero, Mahmoud, Åberg, Magnus, Munkhammar, Joakim · 2022 · Applied Energy
Cited by 172

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The integration of photovoltaic (PV) systems and electric vehicles (EVs) in the built environment, including at workplaces, has increased significantly in the recent decade and has posed new technical challenges for the power system, such as increased peak loads and component overloading. Several studies show that improved matching between PV generation and EV load through both optimal sizing and operation of PV-EV systems can minimize these challenges. This paper presents an optimal PV-EV sizing framework for workplace solar powered charging stations considering load matching performances. The proposed optimal sizing framework in this study uses a novel score, called self-consumption-sufficiency balance (SCSB), which conveys the balance between self-consumption (SC) and self-sufficiency (SS), based on a similar principle as the F1-score in machine learning. A high SCSB score implies that the system is close to being self-sufficient without exporting or curtailing a large share of local production. The results show that the SCSB performance tends to be higher with a larger combined PV-EV size. In addition to presenting PV-EV optimal sizing at the workplace charging station, this study also assesses a potential SC and SS enhancement with optimal operation through smart charging schemes. The results show that smart charging schemes can significantly improve the load matching performances by up to 42.6 and 40.8 percentage points for SC and SS, respectively. The smart charging scheme will also shift the combined optimal PV-EV sizes. Due to its simplicity and universality, the optimal sizing based on SCSB score proposed in this study can be a benchmark for future studies on optimal sizing of PV-EV system, or distributed generation-load in general.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.apenergy.2021.118139

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 172

Metadata

Authors
Fachrizal, R., Shepero, M., Åberg, M., & Munkhammar, J.
Venue
Applied Energy
Publisher
Elsevier BV
Published
2022-02
Volume
307
Pages
118139
ISSN
0306-2619 (ISSN-L)
OpenAlex
W3214410842
Cited by
172
References
5
FWCI
6.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimal PV-EV sizing at solar powered workplace charging stations with smart charging schemes considering self-consumption and self-sufficiency balance. https://app.cochat.ai/papers/10.1016/j.apenergy.2021.118139
The paper
Fachrizal, R., Shepero, M., Åberg, M., & Munkhammar, J. (2022). Optimal PV-EV sizing at solar powered workplace charging stations with smart charging schemes considering self-consumption and self-sufficiency balance. Applied Energy. https://doi.org/10.1016/j.apenergy.2021.118139

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.