Computational modeling and experimental validation of heat recovery ventilator under partially wet conditions
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The numerical results were in reasonable agreement with previous experimental studies by the same authors.”
Citations
Cites
Thermal environmental engineering
(1962) · Journal of the Franklin Institute · doi:10.1016/0016-0032(62)90922-5 · Cited by 930
Thermodynamic properties in SI
Reynolds, W. C. (1979) · Cited by 614
Review on heat recovery technologies for building applications
Mardiana-Idayu, A., & Riffat, S. B. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.09.026 · Cited by 352
A review on polymer heat exchangers for HVAC&R applications
T'Joen, C., Park, Y., Wang, Q., Sommers, A., Han, X., & Jacobi, A. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.008 · Cited by 246
A comprehensive review of heat recovery systems for building applications
Cuce, P. M., & Riffat, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.03.087 · Cited by 192
A review of frosting in air-to-air energy exchangers
Rafati Nasr, M., Fauchoux, M., Besant, R. W., & Simonson, C. J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.10.038 · Cited by 191
Energy wheel effectiveness: part I—development of dimensionless groups
Simonson, C. J., & Besant, R. W. (1999) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00325-1 · Cited by 185
Zhang, L., & Niu, J. (2002) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.1469524 · Cited by 159
Fernández-Seara, J., Diz, R., Uhía, F. J., Dopazo, A., & Ferro, J. M. (2011) · Energy Conversion and Management · doi:10.1016/j.enconman.2010.07.040 · Cited by 119
Theoretical analysis of film condensation heat transfer inside vertical mini triangular channels
Zhao, T. S., & Liao, Q. (2002) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(01)00354-4 · Cited by 111
Research works printed but not linked: 1
- Ping, 2005, Research on a new type of plate air-to-air energy recovery ventilator: product development and experiments, Hv & Ac, 11
Cited by
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86
Enhancing the performance of energy recovery ventilators
Al‐Waked, R., Nasif, M. S., & Mostafa, D. B. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.05.105 · Cited by 52
A review of air-to-air membrane energy recovery technology for building ventilation
Li, J., Shao, S., Wang, Z., Xie, G., Wang, Q., Xu, Z., Han, L., & Gou, X. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112097 · Cited by 45
Tafelmeier, S., Pernigotto, G., & Gasparella, A. (2017) · Buildings · doi:10.3390/buildings7020028 · Cited by 18
“Some of those aspects have been discussed for SHR in a previous work [23], according to a simplified approach based on the experimental results by Nam and Han [24]: the largest variation of sensible effectiveness has been found for the city of Helsinki (Dfb) and is equal to +4% with respect to the nominal effectivenes…”
MethodInfluentialHe, S., Zhou, X., Li, F., Wu, H., Chen, Q., & Lan, Z. (2019) · Heat and Mass Transfer · doi:10.1007/s00231-019-02683-1 · Cited by 17
“When the heat exchanger operates at wet condition by a cold surface, the condensate occurs on the fin-tube surface because the temperature of fin-tube surface of the heat exchanger is below the dew-point temperature of the wet air [21].”
BackgroundPerformance investigation and exergy analysis of enthalpy recovery device using liquid desiccant
Zhang, T., Liu, X., & Jiang, Y. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.06.002 · Cited by 15
Performance of energy recovery ventilators under different climatic regions
Al‐Waked, R., Mostafa, D. B., & Nasif, M. S. (2020) · Energy Efficiency · doi:10.1007/s12053-020-09917-w · Cited by 14
Mortality prediction of laying hens due to heat waves
Riquena, R. D. S., Pereira, D. F., do Vale, M. M., & Salgado, D. D. (2018) · Ciência Agronômica/Revista ciência agronômica · doi:10.5935/1806-6690.20190003 · Cited by 14
Coulombe, F., Rousse, D. R., & Paradis, P.-L. (2020) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2020.07.015 · Cited by 14
Wang, K., Li, N., Peng, J., Wang, X., Wang, C., & Wang, M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.12.023 · Cited by 13
Experimental investigation of condensation in energy recovery ventilators
Abadi, I. R., Aminian, B., Nasr, M. R., Huizing, R., Green, S., & Rogak, S. N. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111732 · Cited by 13
Designing an air-to-air heat exchanger dedicated to single room ventilation with heat recovery
Gendebien, S., Martens, J., Prieels, L., & Lemort, V. (2017) · Building Simulation · doi:10.1007/s12273-017-0386-8 · Cited by 10
Wet-dry thermohydraulic performance comparison on fin-and-tube geometries
Morales-Fuentes, A., Jiménez-Zúñiga, A. M., Alfaro-Ayala, J. A., Loredo-Sáenz, Y. A., & Belman-Flores, J. M. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118881 · Cited by 10
CFD Simulation of Energy Transfer within a Membrane Heat Exchanger under Turbulent Flow
(2023) · Jordan Journal of Mechanical and Industrial Engineering · doi:10.59038/jjmie/170201 · Cited by 9
“The heat recovery process is based on heat transfer process only [42].”
BackgroundExperimental study on performance optimization of air source heat pump using DOE method
Fang, Z., Feng, X., Zheng, Z., Zhou, X., Li, L., Huang, Y. J., Wang, H., & Liu, F. (2018) · Experimental Heat Transfer · doi:10.1080/08916152.2018.1505787 · Cited by 7
“[14] investigated, numerically, the thermal performance of an air-to-air heat exchanger by varying system parameters such as airflow rate, outdoor temperature, and indoor relative humidity.”
BackgroundThermal Performance of Alternating-Current Heat Recovery Ventilator in Partially Wet Conditions
Farizi, A. A., Lee, H., & Han, H. (2021) · Evergreen · doi:10.5109/4372282 · Cited by 5
“Experiments were conducted for a parametric study on sensible plate heat exchangers under condensation conditions 19, 20) .”
Self-citationSun, X., Wang, Z., Li, X., Yang, F., Gao, J., Li, J., & Wang, Z. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.121990 · Cited by 5
Jang, S., Min, S., Song, J., & Hong, H. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.110424 · Cited by 5
Carozza, A. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.01.160 · Cited by 5
Sousa, V. R. D., Sabino, L. A., de Moura, D. J., Nunhez, J. R., Sonoda, L. T., Silva, A. O., Prada, R. J., Fontoura, D. V. R., & Seber, R. T. (2018) · Scientia Agricola · doi:10.1590/1678-992x-2016-0110 · Cited by 5
“A value of 0 Pa for the pressure was defined for the pressure boundary condition at the outlet, which is equivalent to 1 atm (Ansys, 2011; Rong et al., 2016; Nam and Han, 2016).”
BackgroundModelling condensation in energy exchangers with variable permeability membranes
Abadi, I. R., Aminian, B., Nasr, M. R., Huizing, R., Green, S., & Rogak, S. N. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.112015 · Cited by 4
Development of a performance model for classifying broiler farms
Franco, E. A. P., & Nääs, I. D. A. (2021) · Journal of the Indonesian Tropical Animal Agriculture · doi:10.14710/jitaa.47.1.65-75 · Cited by 3
Ratiko, R. (2019) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1198/2/022013 · Cited by 1
“Several experimental and computational modelling studies on natural and mechanical ventilation in rooms with openings were conducted by Hwataik et al.[2,3].”
BackgroundPerformance Comparison of Enthalpy Recovery Devices Using Liquid Desiccant and Desiccant Wheel
Zhang, T., Liu, X., & Xie, Y. (2020) · Journal of Thermal Science and Engineering Applications · doi:10.1115/1.4046063 · Cited by 1
Thermoplastic Composite Heat Recovery Ventilator
Guinn, K. (2019)
Evaluating the Performance of Energy Recovery Systems
Ahmad, M. I., & Riffat, S. (2020) · Springer eBooks · doi:10.1007/978-3-030-50006-1_6
Antonyová, A., Antony, P., & Joelianto, E. (2021) · Advances in intelligent systems and computing · doi:10.1007/978-981-33-4062-6_1
Badache, M., Viviescas, G., Fortier, R., & Tareen, M. S. K. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116725
Metadata
- Authors
- Nam, S.-H., & Han, H.
- Affiliations
- Kookmin University (KR)
- Corresponding author
- Han, Hwataik
- ORCID
- Han, Hwataik
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2016-02
- Volume
- 95
- Pages
- 229-235
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2190717191
- Cited by
- 27
- References
- 20
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 4
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Applied Thermal Engineering (publishedVersion)
- Funders
- National Research Foundation of Korea (31Z20130012959)
- Korea Institute of Energy Technology Evaluation and Planning (20134040200580)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- heat recovery ventilator, plate heat exchanger, condensation, latent heat, air-to-air heat exchanger, temperature efficiency, broiler houses, relative humidity, condensation rate, surface temperature distribution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.