PCM integrated to external building walls: An optimization study on maximum activation of latent heat
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Abstract Integration of the phase change materials (PCM) into the external building walls is an efficient method for reduction of energy consumption and regulation of energy demands due to increasing thermal inertia of the walls. This study aims to reveal the contribution of latent heat to the thermal performance of the wall and to determine the location, thickness and melting temperature of PCM for the maximum exploitation of latent heat for different climatic conditions. A comparative study is carried out for the wall coupled with PCM and the wall with Phase Stabilized PCM (PSM) to reveal the improvement provided by the latent heat. The influence of location, fusion temperature and layer thickness of PCM on energy saving, decrement factor and time lag was examined. The annually optimized PCM fusion temperature and layer thickness which utilizes the latent heat at maximum level considering both heating and cooling loads are determined for three cities of Turkey. The computed results show that the monthly optimized PCM melting temperature and PCM layer thickness vary from 6 to 34 °C, from 1 to 20 mm depending on climatic conditions. It was concluded that an optimization study should be conducted in order to prevent PCM behaves like PSM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updated world map of the Köppen-Geiger climate classification
Peel, M. C., Finlayson, B. L., & McMahon, T. A. (2007) · doi:10.5194/hessd-4-439-2007 · Cited by 13,640
Updated world map of the Köppen-Geiger climate classification
(2007) · doi:10.5194/hess-11-1633-2007 · Cited by 13,640
Zalba, B., Marı́n, J. M., Cabeza, L. F., & Mehling, H. (2003) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00192-8 · Cited by 4,738
Long‐wave radiation from clear skies
Swinbank, W. C. (1963) · Quarterly Journal of the Royal Meteorological Society · doi:10.1002/qj.49708938105 · Cited by 1,631
A review on phase change material (PCM) for sustainable passive cooling in building envelopes
Akeiber, H., Nejat, P., Majid, M. Z. A., Wahid, M. A., Jomehzadeh, F., Zeynali Famileh, I., Calautit, J. K., Hughes, B. R., & Zaki, S. A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.036 · Cited by 1,075
Use of microencapsulated PCM in concrete walls for energy savings
Cabeza, L. F., Castellón, C., Nogués, M., Medrano, M., Leppers, R., & Zubillaga, O. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.030 · Cited by 889
Investigation of the thermal performance of a passive solar test-room with wall latent heat storage
Athienitis, A. K., Liu, C., Hawes, D., Banu, D., & Feldman, D. (1997) · Building and Environment · doi:10.1016/s0360-1323(97)00009-7 · Cited by 439
Koschenz, M., & Lehmann, B. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.01.029 · Cited by 371
Saffari, M., de Gracia, A., Fernández, C., & Cabeza, L. F. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.107 · Cited by 343
Optimization of a phase change material wallboard for building use
Kuznik, F., Virgone, J., & Noel, J. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.10.012 · Cited by 319
Živković, B., & FUJII, I. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00112-2 · Cited by 298
Numerical analysis on thermal performance of roof contained PCM of a single residential building
Li, D., Zheng, Y., Liu, C., & Wu, G. (2015) · Energy Conversion and Management · doi:10.1016/j.enconman.2015.05.014 · Cited by 278
Energy and economic analysis of building integrated with PCM in different cities of China
Mi, X., Liu, R., Cui, H., Memon, S. A., Xing, F., & Lo, T. Y. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.05.032 · Cited by 273
Ali, H. M., Ashraf, M. J., Giovannelli, A., Irfan, M., Irshad, T. B., Hamid, H. M., Hassan, F., & Arshad, A. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.02.044 · Cited by 248
Application of PCM thermal energy storage system to reduce building energy consumption
Jeon, J., Lee, J.-H., Seo, J., Jeong, S.-G., & Kim, S. (2013) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-012-2291-9 · Cited by 228
Novel concept of composite phase change material wall system for year-round thermal energy savings
Diaconu, B., & Cruceru, M. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.05.012 · Cited by 221
Marin, P., Saffari, M., de Gracia, A., Zhu, X., Farid, M. M., Cabeza, L. F., & Ushak, S. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.007 · Cited by 210
PCM-module to improve hot water heat stores with stratification
Mehling, H., Cabeza, L. F., Hippeli, S., & Hiebler, S. (2002) · Renewable Energy · doi:10.1016/s0960-1481(02)00108-8 · Cited by 203
Guarino, F., Athienitis, A. K., Cellura, M., & Bastien, D. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.10.046 · Cited by 192
A numerical study of external building walls containing phase change materials (PCM)
Izquierdo-Barrientos, M. A., Belmonte, J. F., Rodríguez-Sánchez, D., Molina, A. E., & Almendros-Ibáñez, J. A. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.02.038 · Cited by 189
Energy investigation of glazed windows containing Nano-PCM in different seasons
Li, D., Wu, Y., Liu, C., Zhang, G., & Arıcı, M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.07.015 · Cited by 182
Self-citationZwanzig, S. D., Lian, Y., & Brehob, E. G. (2013) · Energy Conversion and Management · doi:10.1016/j.enconman.2013.02.003 · Cited by 176
Energy storage applications in greenhouses by means of phase change materials (PCMs): a review
Kürklü, A. (1998) · Renewable Energy · doi:10.1016/s0960-1481(97)83337-x · Cited by 173
Modeling of phase change material peak load shifting
Halford, C. K., & Boehm, R. F. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.07.005 · Cited by 156
Application of phase change materials in gypsum boards to meet building energy conservation goals
Sharifi, N. P., Shaikh, A. A. N., & Sakulich, A. R. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.12.046 · Cited by 152
Ye, H., Long, L., Zhang, H., & Zou, R. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.08.067 · Cited by 141
Parametric analysis of influencing factors in Phase Change Material Wallboard (PCMW)
Zhou, D., Shire, G. S. F., & Tian, Y. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.12.059 · Cited by 134
Radiant floors integrated with PCM for indoor temperature control
Ansuini, R., Larghetti, R., Giretti, A., & Lemma, M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.018 · Cited by 133
Analytical optimization of interior PCM for energy storage in a lightweight passive solar room
Xiao, W., Wang, X., & Zhang, Y. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.12.011 · Cited by 133
Cascone, Y., Capozzoli, A., & Perino, M. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.11.081 · Cited by 132
Li, D., Wu, Y., Zhang, G., Arıcı, M., Liu, C., & Wang, F. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.015 · Cited by 131
Self-citationSun, X., Zhang, Q., Medina, M. A., & Lee, K. O. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.03.035 · Cited by 127
Xie, J., Wang, W., Liu, J., & Pan, S. (2018) · Solar Energy · doi:10.1016/j.solener.2018.01.069 · Cited by 123
Parametric analysis of using PCM walls for heating loads reduction
Wang, Q., Wu, R., Wu, Y., & Zhao, C. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.05.012 · Cited by 120
Nižetić, S., Arıcı, M., Bilgin, F., & Grubišić‐Čabo, F. (2017) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.09.164 · Cited by 117
Self-citationSchröder, J., & Gawron, K. (1981) · International Journal of Energy Research · doi:10.1002/er.4440050202 · Cited by 108
Indoor thermal comfort assessment using different constructive solutions incorporating PCM
Figueiredo, A., Vicente, R., Lapa, J., Cardoso, C., Rodrigues, F., & Kämpf, J. H. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.09.032 · Cited by 103
Huang, M. J., Eames, P., & Hewitt, N. (2006) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2006.02.002 · Cited by 96
Li, D., Wu, Y., Liu, C., Zhang, G., & Arıcı, M. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.04.152 · Cited by 96
Self-citationZhou, G., Yang, Y., Wang, X., & Cheng, J. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.02.001 · Cited by 95
Using PCM embedded in building material for thermal management: Performance assessment study
Elnajjar, E. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.06.010 · Cited by 90
Numerical and experimental investigation of an insulation layer with phase change materials (PCMs)
Fateh, A., Klinker, F., Brütting, M., Weinläder, H., & Devia, F. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.007 · Cited by 85
Brano, V. L., Ciulla, G., Piacentino, A., & Cardona, F. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.01.043 · Cited by 81
Thermal performance of non-ventilated multilayer glazing facades filled with phase change material
Liu, C., Zhang, G., Arıcı, M., Bian, J., & Li, D. (2018) · Solar Energy · doi:10.1016/j.solener.2018.11.044 · Cited by 80
Self-citationPark, J. H., Lee, J., Wi, S., Jeon, J., Chang, S. J., Chang, J. D., & Kim, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.013 · Cited by 63
Mazzeo, D., & Oliveti, G. (2018) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2017.12.026 · Cited by 48
Mazzeo, D., Oliveti, G., & Arcuri, N. (2017) · Energies · doi:10.3390/en10050659 · Cited by 43
Mazzeo, D., Oliveti, G., & Arcuri, N. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.02.027 · Cited by 40
Mazzeo, D., Oliveti, G., de Gracia, Á., Coma, J., Solé, A., & Cabeza, L. F. (2017) · Energy · doi:10.1016/j.energy.2017.08.045 · Cited by 40
Internal surfaces including phase change materials for passive optimal shift of solar heat gain
Arnault, A., Mathieu-Potvin, F., & Gosselin, L. (2010) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2010.06.021 · Cited by 35
Cited by
Latent thermal energy storage technologies and applications: A review
Jouhara, H., Żabnieńska-Góra, A., Khordehgah, N., Ahmad, D., & Lipinski, T. (2020) · International Journal of Thermofluids · doi:10.1016/j.ijft.2020.100039 · Cited by 543
Wang, X., Li, W., Luo, Z., Wang, K., & Shah, S. P. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111923 · Cited by 493
Al-Yasiri, Q., & Szabó, M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.102122 · Cited by 432
Thermophysical properties and applications of nano-enhanced PCMs: An update review
Yang, L., Huang, J.-N., & Zhou, F. (2020) · Energy Conversion and Management · doi:10.1016/j.enconman.2020.112876 · Cited by 343
Hassan, F., Jamil, F., Hussain, A., Ali, H. M., Janjua, M. M., Khushnood, S., Farhan, M., Altaf, K., Said, Z., & Li, C. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101646 · Cited by 283
Metadata
- Authors
- Arıcı, M., Bilgin, F., Nižetić, S., & Karabay, H.
- Venue
- Applied Thermal Engineering
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 165
- Pages
- 114560
- ISSN
- 1359-4311 (ISSN-L)
- OpenAlex
- W2980569436
- Cited by
- 324
- References
- 50
- FWCI
- 20.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.