CoChat

An In Vivo Biomechanical Study on the Tension–Versus–Knee Flexion Angle Curves of 2 Grafts in Anatomic Double-Bundle Anterior Cruciate Ligament Reconstruction: Effects of Initial Tension and Internal Tibial Rotation

Yasuda, Kazunori, Ichiyama, Hiroki, Kondo, Eiji, Miyatake, Shin, Inoue, Masayuki, Tanabe, Yoshie · 2008 · Arthroscopy: The Journal of Arthroscopic & Related Surgery
Cited by 92

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: The purposes of this study were to determine the relation between the graft tension and the knee flexion angle in the anteromedial (AM) and posterolateral (PL) bundles of a clinically simulated anatomic double-bundle anterior cruciate ligament (ACL) reconstruction procedure and to clarify the effect of initial tension on the tension-versus-flexion curve of each graft, as well as the effect of internal rotation of the tibia on the tension of the 2 grafts. METHODS: During ACL reconstruction in 30 patients, 2 suture anchors with a No. 1 polyester suture were firmly screwed into the center of the anatomic attachment of the AM and PL bundles on the femur, respectively, and each graft tension was measured with a strain gauge-type tensiometer attached at the end of the suture under 2 conditions of initial tension. RESULTS: The averaged tension-versus-flexion curves were significantly different between the AM and PL grafts under each initial tension condition (P < .0001). The initial tension applied at 30 degrees of knee flexion significantly affected the absolute values of each graft tension at each knee flexion angle (P < .0001) but did not significantly affect the tension-versus-flexion curve pattern of each graft. The maximal internal rotation of the tibia significantly increased the tension on both the AM and PL grafts at knee flexion angles of less than 60 degrees under each initial tension condition (P < .0001). CONCLUSIONS: The tension-versus-flexion curves of the 2 sutures, which mimicked the AM and PL grafts reconstructed clinically with the anatomic double-bundle ACL reconstruction procedure, were significantly different in the tension values. Differences in initial tension applied to the 2 grafts significantly affected the absolute values of each graft tension at each knee flexion angle but did not significantly affect the tension-versus-flexion curve pattern. The maximal internal rotation of the tibia significantly increased the tension on both the AM and PL suture grafts at knee flexion angles of less than 60 degrees . LEVEL OF EVIDENCE: Level I, testing of previously developed diagnostic criteria in series of consecutive patients with universally applied gold standard.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.arthro.2007.08.031

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Yasuda, K., Ichiyama, H., Kondo, E., Miyatake, S., Inoue, M., & Tanabe, Y.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2008-03
Volume
24
Issue
3
Pages
276-284
ISSN
0749-8063 (ISSN-L)
OpenAlex
W2097216377
Cited by
92
References
1
FWCI
8.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.