The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Comparison of Magnetic Resonance Imaging Findings in Anterior Cruciate Ligament Grafts With and Without Autologous Platelet-Derived Growth Factors
Abstract
PURPOSE: To determine whether the use of platelet-rich plasma gel (PRPG) affects magnetic resonance imaging (MRI) findings in the anterior cruciate ligament (ACL) graft during the first year after reconstruction. METHODS: A prospective single-blinded study of 50 ACL reconstructions in 50 patients was performed. In group A (study group) PRPG was added to the graft with a standardized technique, and in group B (control group) no PRPG was added. An MRI study was performed postoperatively between 3 and 9 months in group A and between 3 and 12 months in group B. The imaging analysis was performed in a blind protocol by the same radiologist. RESULTS: The mean heterogeneity score value at the time of MRI, assigned by the radiologist, was 1.14 in group A and 3.25 in group B. Both groups were comparable in terms of sex and age (P < .05). The mean time to obtain a completely homogeneous intra-articular segment in group A (PRPG added) was 177 days after surgery, and it was 369 days in group B. Using the quadratic predictive model, these findings show that group A (PRPG added) needed only 48% of the time group B required to achieve the same MRI image (P < .001). CONCLUSIONS: ACL reconstruction with the use of PRPG achieves complete homogeneous grafts assessed by MRI, in 179 days compared with 369 days for ACL reconstruction without PRPG. This represents a time shortening of 48% with respect to ACL reconstruction without PRPG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Revascularization and ligamentization of autogenous anterior cruciate ligament grafts in humans
Falconiero, R., DiStefano, V., & Cook, T. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70041-6 · Cited by 219
Weiler, A., Förster, C., Hunt, P., Falk, R., Jung, T., Unterhauser, F. N., Bergmann, V., Schmidmaier, G., & Haas, N. P. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261711 · Cited by 131
Rougraff, B. T., & Shelbourne, K. D. (1999) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050113 · Cited by 76
Cited by
Platelet-Rich Plasma: A Milieu of Bioactive Factors
Boswell, S. G., Cole, B. J., Sundman, E. A., Karas, V., & Fortier, L. A. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.10.018 · Cited by 613
Chahla, J., Cinque, M. E., Piuzzi, N. S., Mannava, S., Geeslin, A. G., Murray, I. R., Dornan, G. J., Muschler, G. F., & LaPrade, R. F. (2017) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.16.01374 · Cited by 504
Castillo, T. N., Pouliot, M. A., Kim, H. J., & Dragoo, J. L. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510387517 · Cited by 498
Ljungqvist, A., Jenoure, P., Engebretsen, L., Alonso, J. M., Bahr, R., Clough, A., De Bondt, G., Dvorak, J., Maloley, R., Matheson, G., et al. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2009.064394 · Cited by 431
Riboh, J. C., Saltzman, B. M., Yanke, A. B., Fortier, L., & Cole, B. J. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546515580787 · Cited by 417
Metadata
- Authors
- Radice, F., Yánez, R., Gutiérrez, V., Rosales, J., Pinedo, M., & Coda, S.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 26
- Issue
- 1
- Pages
- 50-57
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2105885710
- Cited by
- 233
- References
- 3
- FWCI
- 15.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Magnetic Resonance Imaging Findings in Anterior Cruciate Ligament Grafts With and Without Autologous Platelet-Derived Growth Factors. https://app.cochat.ai/papers/10.1016/j.arthro.2009.06.030
- The paper
- Radice, F., Yánez, R., Gutiérrez, V., Rosales, J., Pinedo, M., & Coda, S. (2010). Comparison of Magnetic Resonance Imaging Findings in Anterior Cruciate Ligament Grafts With and Without Autologous Platelet-Derived Growth Factors. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/j.arthro.2009.06.030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.