The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A Prospective, Randomized Evaluation of Acellular Human Dermal Matrix Augmentation for Arthroscopic Rotator Cuff Repair
Abstract
PURPOSE: To prospectively evaluate the safety and effectiveness of arthroscopic acellular human dermal matrix augmentation of large rotator cuff tear repairs. METHODS: A prospective, institutional review board-approved, multicenter series of patients undergoing arthroscopic repair of 2-tendon rotator cuff tears measuring greater than 3 cm were randomized by sealed envelopes opened at the time of surgery to arthroscopic single-row rotator cuff repair with GraftJacket acellular human dermal matrix (Wright Medical Technology, Arlington, TN) augmentation (group 1) or without augmentation (group 2). Preoperative and postoperative functional outcome assessments were obtained by use of the American Shoulder and Elbow Surgeons (ASES), Constant, and University of California, Los Angeles scales. Gadolinium-enhanced magnetic resonance imaging (MRI) evaluation of these repairs was obtained at a mean of 14.5 months (range, 12 to 24 months). Adverse events were recorded. RESULTS: There were 22 patients in group 1 and 20 in group 2 with a mean age of 56 years. The mean follow-up was 24 months (range, 12 to 38 months). The ASES score improved from 48.5 to 98.9 in group 1 and from 46.0 to 94.8 in group 2. The scores in group 1 were statistically better than those in group 2 (P = .035). The Constant score improved from 41.0 to 91.9 in group 1 and from 45.8 to 85.3 in group 2. The scores in group 1 were statistically better than those in group 2 (P = .008). The University of California, Los Angeles score improved from 13.3 to 28.2 in group 1 and from 15.9 to 28.3 in group 2 (P = .43). Gadolinium-enhanced MRI scans showed intact cuffs in 85% of repairs in group 1 and 40% in group 2 (P < .01). No adverse events were attributed to the presence of the matrix grafts. CONCLUSIONS: Acellular human dermal matrix augmentation of large (>3 cm) cuff tears involving 2 tendons showed better ASES and Constant scores and more frequent intact cuffs as determined by gadolinium-enhanced MRI. Intact repairs were found in 85% of the augmented group and 40% of the nonaugmented group (P < .01). No adverse events related to the acellular human dermal matrix were observed. LEVEL OF EVIDENCE: Level II, lesser-quality randomized controlled trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00512 · Cited by 859
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200705000-00006 · Cited by 620
Scoring Systems for the Functional Assessment of the Shoulder
Kirkley, A., Griffin, S., & Dainty, K. (2003) · Arthroscopy · doi:10.1016/j.arthro.2003.10.030 · Cited by 504
IANNOTTI, J. P., CODSI, M. J., KWON, Y. W., DERWIN, K., CICCONE, J., & BREMS, J. J. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200606000-00010 · Cited by 479
Lafosse, L., Brozska, R., Toussaint, B., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00305 · Cited by 394
Cole, B. J., McCarty, L. P., Kang, R. W., Alford, W., Lewis, P. B., & Hayden, J. K. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2006.12.011 · Cited by 303
Sclamberg, S. G., Tibone, J. E., Itamura, J. M., & Kasraeian, S. (2004) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2004.03.005 · Cited by 284
Rotator Cuff Repair Using an Acellular Dermal Matrix Graft: An In Vivo Study in a Canine Model
Adams, J. E., Zobitz, M. E., Reach, J. S., An, K.-N., & Steinmann, S. P. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.03.016 · Cited by 248
Restore Orthobiologic Implant: Not Recommended for Augmentation of Rotator Cuff Repairs
Walton, J. R., Bowman, N. K., Khatib, Y., Linklater, J., & Murrell, G. A. C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00013 · Cited by 239
Badhe, S. P., Lawrence, T. M., Smith, F. D., & Lunn, P. G. (2008) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.08.005 · Cited by 236
Massive rotator cuff tears: The result of partial rotator cuff repair
Duralde, X. A., & Bair, B. (2005) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2004.06.015 · Cited by 204
DeFranco, M. J., Bershadsky, B., Ciccone, J., Yum, J.-K., & Iannotti, J. P. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.03.020 · Cited by 166
Snyder, S. J., Arnoczky, S. P., Bond, J. L., & Dopirak, R. (2009) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2008.05.023 · Cited by 161
Soler, J. A., Gidwani, S., & Curtis, M. J. (2007) · PubMed · Cited by 143
Biomechanical Testing of Commercially Available Soft‐Tissue Augmentation Materials
Barber, F. A., & Aziz-Jacobo, J. (2009) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2009.05.012 · Cited by 95
Self-citationHistologic Evaluation of a 6-Month GraftJacket Matrix Biopsy Used for Achilles Tendon Augmentation
Liden, B. A., & Simmons, M. (2009) · Journal of the American Podiatric Medical Association · doi:10.7547/0980104 · Cited by 29
Cited by
Tendon and ligament regeneration and repair: Clinical relevance and developmental paradigm
Yang, G., Rothrauff, B. B., & Tuan, R. S. (2013) · Birth Defects Research Part C: Embryo Today: Reviews · doi:10.1002/bdrc.21041 · Cited by 469
Parmaksiz, M., Dogan, A., Odabas, S., Elçin, A. E., & Elçin, Y. M. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/2/022003 · Cited by 268
Metadata
- Authors
- Barber, F. A., Burns, J. P., Deutsch, A., Labbé, M. R., & Litchfield, R. B.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 28
- Issue
- 1
- Pages
- 8-15
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2010937757
- Cited by
- 433
- References
- 18
- FWCI
- 13.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.