Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Purpose of review: Continuous wave near infrared spectroscopy (CW NIRS) provides non-invasive technology to measure relative changes in oxy-and deoxy-haemoglobin in a dynamic environment.This allows determination of local skeletal muscle O 2 saturation, muscle oxygen consumption ( _ VO 2 ) and blood flow.This article provides a brief overview of the use of CW NIRS to measure exercise-limiting factors in skeletal muscle.Recent findings: NIRS parameters that measure O 2 delivery and capacity to utilise O 2 in the muscle have been developed based on response to physiological interventions and exercise.NIRS has good reproducibility and agreement with gold standard techniques and can be used in clinical populations where muscle oxidative capacity or oxygen delivery (or both) are impaired.CW NIRS has limitations including: the unknown contribution of myoglobin to the overall signals, the impact of adipose tissue thickness, skin perfusion during exercise, and variations in skin pigmentation.These, in the main, can be circumvented through appropriate study design or measurement of absolute tissue saturation.Summary: CW NIRS can assess skeletal muscle O 2 delivery and utilisation without the use of expensive or invasive procedures and is useable in large population-based samples, including older adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 1×
“Due to the stability of arterial O2 saturation, saturation changes that are unrelated to cardiac pulsatility or muscle contraction, are thought to predominantly represent changes in the venous compartment.(9,18) A hydrostatic change imposed by tilting from supine to upright results in venous filling and has been used…”
BackgroundRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“small arteries, arterioles, capillaries and venules).(18,19) It is generally assumed that the major part of the Hb-related NIRS signal arises from capillaries since these micro-vessels compose the largest portion of vascular volume in skeletal muscle.”
BackgroundMonitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469 · cited 2×
“Due to the stability of arterial O2 saturation, saturation changes that are unrelated to cardiac pulsatility or muscle contraction, are thought to predominantly represent changes in the venous compartment.(9,18) A hydrostatic change imposed by tilting from supine to upright results in venous filling and has been used…”
BackgroundFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450 · cited 1×
“exercise) in skeletal muscle complicating the interpretation of NIRS data.(5,17)”
BackgroundVan Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430 · cited 2×
“Venous occlusion derived _ VO2 values show higher variability(49) and poorer reproducibility.(50) The lower values measured by arterial occlusion may be explained by continued inflow of arterial blood during venous occlusion.”
BackgroundAdipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Cited by
A high efficiency broad-band near-infrared Ca2LuZr2Al3O12:Cr3+ garnet phosphor for blue LED chips
Zhang, L., Zhang, S., Hao, Z., Zhang, X., Pan, G.-H., Luo, Y., Wu, H., & Zhang, J. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc01216d · Cited by 348
Jones, S., D'Silva, A., Bhuva, A., Lloyd, G., Manisty, C., Moon, J. C., Sharma, S., & Hughes, A. D. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.01018 · Cited by 47
Self-citationTuesta, M., Yáñez-Sepúlveda, R., Verdugo-Marchese, H., Mateluna, C., & Alvear-Ordenes, I. (2022) · Biology · doi:10.3390/biology11071073 · Cited by 37
Koutlas, A., Smilios, I., Kokkinou, E. M., Myrkos, A., Kounoupis, A., Dipla, K., & Zafeiridis, A. (2024) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2022.2159309 · Cited by 18
“…primarily reflects the function of capillaries, as these micro-vessels compose the largest portion of vascular volume in skeletal muscle (>90%; Jones et al., 2016; Jonk et al., 2007) and they function mainly to supply oxygen to muscle fibers playing an important role in whole-body VO 2 during…”
BackgroundZheng, C., Muir, K., Kaushik, H., Yalamanchili, K., Zahiri, K., Yeo, A., Kim, J., & Sellke, F. W. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1843167 · Cited by 6
“Second, the accuracy of measurements is influenced by local tissue characteristics such as adiposity, probe placement, and skin pigmentation (80).”
Surface Acoustic Wave (SAW) force myography sensor for muscle force output identification
Kohler, M. C., Voiculescu, I., & Li, F. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2024.115959 · Cited by 5
Metadata
- Authors
- Jones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D.
- Venue
- Artery Research
- Published
- 2016
- Volume
- 16
- Issue
- C
- Pages
- 25
- ISSN
- 1872-9312 (ISSN-L)
- 1876-4401
- OpenAlex
- W2524155347
- Cited by
- 184
- References
- 67
- FWCI
- 23.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.