CoChat

Biomatrix/Polymer Composite Material for Heart Valve Tissue Engineering

Open access
Stamm, Christof, Khosravi, Amir, Grabow, Niels, Schmohl, Kathleen, Treckmann, Nadine, Drechsel, Anne, Nan, Ma, Schmitz, Klaus-Peter, Haubold, Axel, Steinhoff, Gustav · 2004 · The Annals of Thoracic Surgery
Cited by 102

The DOI matches its Crossref record.

Abstract

BACKGROUND Decellularized extracellular matrix has been suggested as a scaffold for heart valve tissue engineering or direct implantation. However, cell removal impairs the physical properties of the valve structure and exposes bare collagen fibers that are highly thrombogenic. Matrix/polymer hybrid valves with improved biological and mechanical characteristics may be advantageous. METHODS Porcine aortic valves were decellularized enzymatically and impregnated with biodegradable poly(hydroxybutyrate) by a stepwise solvent exchange process. Biocompatibility was tested in vitro using cell proliferation and coagulation assays. Proinflammatory activity was assessed in vivo by implantation of matrix/polymer patches in the rabbit aorta. Biomechanic valve properties and fluid dynamics were tested in a pressure/flow-controlled pulse duplicating system. Matrix/polymer hybrid valves were implanted in pulmonary and aortic position in sheep. RESULTS Biocompatibility assays indicated that human blood vessel cells survive and proliferate on matrix/polymer hybrid tissue. In vitro activation of cellular and plasmatic coagulation cascades was lower than with uncoated control tissue. After implantation in the rabbit aorta, matrix/polymer hybrid patches healed well, with complete endothelialization, mild leukocyte infiltration, and less calcification than control tissue. Matrix/polymer hybrid tissue had superior tensile strength and suture retention strength, and hybrid valves showed good fluid dynamic performance. The two valves in aortic position performed well, with complete endothelialization and limited inflammatory cell invasion after 12 weeks. Of the two valves in pulmonary position, one failed. CONCLUSIONS Matrix/polymer hybrid tissue valves have good biological and biomechanic characteristics and may provide superior replacement valves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.athoracsur.2004.03.106

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 102

Metadata

Authors
Stamm, C., Khosravi, A., Grabow, N., Schmohl, K., Treckmann, N., Drechsel, A., Nan, M., Schmitz, K.-P., Haubold, A., & Steinhoff, G.
Venue
The Annals of Thoracic Surgery
Publisher
Elsevier BV
Published
2004-12
Volume
78
Issue
6
Pages
2084-2093
ISSN
0003-4975 (ISSN-L)
OpenAlex
W2007255341
Cited by
102
References
0
FWCI
5.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biomatrix/Polymer Composite Material for Heart Valve Tissue Engineering. https://app.cochat.ai/papers/10.1016/j.athoracsur.2004.03.106
The paper
Stamm, C., Khosravi, A., Grabow, N., Schmohl, K., Treckmann, N., Drechsel, A., Nan, M., Schmitz, K.-P., Haubold, A., & Steinhoff, G. (2004). Biomatrix/Polymer Composite Material for Heart Valve Tissue Engineering. The Annals of Thoracic Surgery. https://doi.org/10.1016/j.athoracsur.2004.03.106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.