The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Heart Valve Tissue Engineering
Open accessAbstract
Tissue-engineered heart valves have been proposed by physicians and scientists alike to be the ultimate solution for treating valvular heart disease. Rather than replacing a diseased or defective native valve with a mechanical or animal tissue–derived artificial valve, a tissue-engineered valve would be a living organ, able to respond to growth and physiological forces in the same way that the native aortic valve does. Two main approaches have been attempted over the past 10 to 15 years: regeneration and repopulation. Regeneration involves the implantation of a resorbable matrix that is expected to remodel in vivo and yield a functional valve composed of the cells and connective tissue proteins of the patient. Repopulation involves implanting a whole porcine aortic valve that has been previously cleaned of all pig cells, leaving an intact, mechanically sound connective tissue matrix. The cells of the patients are expected to repopulate and revitalize the acellular matrix, creating living tissue that already has the complex microstructure necessary for proper function and durability. Regrettably, neither of the 2 approaches has fared well in animal experiments, and the only clinical experience with tissue-engineered valves resulted in a number of early failures and patient death. This article reviews the technological details of the 2 main approaches, their rationale, their strengths and weaknesses, and the likely mechanisms for their failure. Alternative approaches to valvular tissue engineering, as well as the role of industry in shaping this field in the future, are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Rieder, E., Kasimir, M.-T., Silberhumer, G., Seebacher, G., Wolner, E., Simon, P., & Weigel, G. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.06.017 · Cited by 430
Cited by
3D Bioprinting of heterogeneous aortic valve conduits with alginate/gelatin hydrogels
Duan, B., Hockaday, L. A., Kang, K. H., & Butcher, J. T. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34420 · Cited by 1,002
Mikos, A. G., Herring, S. W., Ochareon, P., Elisseeff, J., Lu, H. H., Kandel, R., Schoen, F. J., Toner, M., Mooney, D., Atala, A., et al. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.3307 · Cited by 598
Schoen, F. J. (2008) · Circulation · doi:10.1161/circulationaha.108.805911 · Cited by 421
Tissue Engineering Based on Cell Sheet Technology
Matsuda, N., Shimizu, T., Yamato, M., & Okano, T. (2007) · Advanced Materials · doi:10.1002/adma.200701978 · Cited by 398
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Metadata
- Authors
- Vesely, I.
- Venue
- Circulation Research
- Published
- 2005-10-14
- Volume
- 97
- Issue
- 8
- Pages
- 743-755
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2028624725
- Cited by
- 309
- References
- 2
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart Valve Tissue Engineering. https://app.cochat.ai/papers/10.1161/01.res.0000185326.04010.9f
- The paper
- Vesely, I. (2005). Heart Valve Tissue Engineering. Circulation Research. https://doi.org/10.1161/01.res.0000185326.04010.9f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.