CoChat

Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery

Green, Jessica, Ryer, Evan, Borden, Nicholas, Ali, Bilal, Garvin, Robert, Yang, Andrew, Hashmi, Ammar, Salzler, Gregory, Elmore, James · 2021 · Annals of Vascular Surgery
Cited by 8

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE This study sought to define duplex ultrasound (DUS) velocity criteria predicting ≥70% stenosis in superior mesenteric artery (SMA) stents by correlating in-stent peak systolic velocity (PSV) with computed tomographic angiography (CTA) measurements of percent stenosis. METHODS A retrospective review of 109 patients undergoing SMA stenting between 2003 and 2018 was conducted at a single institution. Thirty-seven surveillance duplex ultrasound studies were found to have a CTA performed within 30 days of study completion. Bare metal (n=20) and covered stents (n=17) were included. Velocities were paired to in-stent restenosis (ISR) measured by mean vessel diameter reduction on SMA centerline reconstructions from CTA. Receiver operating characteristic (ROC) curves were generated and logistic regression models for ≥70% ISR probability were used to define velocity criteria in the stented SMA. RESULTS At a PSV of 300 cm/sec, the sensitivity is 100% and specificity 80% for a ≥70% in-stent SMA stenosis. At a PSV of 400 cm/sec, the sensitivity and positive predictive value (PPV) is 63% and the specificity and negative predictive value (NPV) is 90%. A PSV of 450 cm/sec was consistent with the highest specificity (100%) and PPV (100%) but lower sensitivity (50%) and NPV (87.9%). One patient with a PSV of 441 cm/sec on surveillance DUS died from complications of acute-on-chronic mesenteric ischemia. CONCLUSIONS A PSV of 400 cm/sec on mesenteric DUS can predict ≥70% ISR with high sensitivity and should be considered as a diagnostic threshold for SMA in-stent restenosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.avsg.2020.12.023

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 8

Metadata

Authors
Green, J., Ryer, E., Borden, N., Ali, B., Garvin, R., Yang, A., Hashmi, A., Salzler, G., & Elmore, J.
Venue
Annals of Vascular Surgery
Publisher
Elsevier BV
Published
2021-07
Volume
74
Pages
294-300
ISSN
0890-5096 (ISSN-L)
OpenAlex
W3123976936
Cited by
8
References
11
FWCI
0.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery. https://app.cochat.ai/papers/10.1016/j.avsg.2020.12.023
The paper
Green, J., Ryer, E., Borden, N., Ali, B., Garvin, R., Yang, A., Hashmi, A., Salzler, G., & Elmore, J. (2021). Defining Duplex Ultrasound Criteria for In-Stent Restenosis of the Superior Mesenteric Artery. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2020.12.023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.