CoChat

Intent based recognition of walking and ramp activities for amputee using sEMG based lower limb prostheses

Hussain, Tahir, Iqbal, Nadeem, Maqbool, Hafiz Farhan, Khan, Mukhtaj, Awad, Mohammed Ibrahim, Dehghani-Sanij, Abbas A. · 2020 · Biocybernetics and Biomedical Engineering
Cited by 58

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The use of surface electromyogram (sEMG) has grown in the field of gait analysis, prostheses and exoskeleton. Surface electromyogram can directly reflect the human intention for locomotion modes and can be used as a source of control for lower limb prosthesis. The variations factors such as non-Gaussian nature of sEMG signal and mobility of amputees have been observed to degrade the activity recognition performance. This study investigates the properties of the sEMG signal with the purpose of determining the discriminant features to classify the feature space into various activities especially in the context of amputees. To address the variations in activity recognition performance, this study proposed the magnitude of bispectrum as a novel feature extraction method that is invariant to the variations factors and an unsupervised feature reduction method was used to extract the discriminant features. Furthermore, sEMG signals from eleven wearable sensors located on the lower limb muscles were recorded from six subjects including four able-bodies, one unilateral transtibial, and one unilateral transfemoral amputee during walking and ramp activities. Distinct muscles were selected using the L1-norm method. Effective classifier namely support vector machine and linear discriminant analysis were used to classify the multi-class sEMG signal patterns. The experimental results consistently showed an average accuracy of 99.7%. Further evaluation on three different types of prostheses revealed that the proposed method is more robust compared to the existing methods. The promising results of this study can be applied potentially in the control of lower limb wearable devices such as prostheses/exoskeletons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bbe.2020.05.010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 58

Metadata

Authors
Hussain, T., Iqbal, N., Maqbool, H. F., Khan, M., Awad, M. I., & Dehghani-Sanij, A. A.
Venue
Biocybernetics and Biomedical Engineering
Publisher
Elsevier BV
Published
2020-07
Volume
40
Issue
3
Pages
1110-1123
ISSN
0208-5216 (ISSN-L)
OpenAlex
W3032981784
Cited by
58
References
1
FWCI
2.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intent based recognition of walking and ramp activities for amputee using sEMG based lower limb prostheses. https://app.cochat.ai/papers/10.1016/j.bbe.2020.05.010
The paper
Hussain, T., Iqbal, N., Maqbool, H. F., Khan, M., Awad, M. I., & Dehghani-Sanij, A. A. (2020). Intent based recognition of walking and ramp activities for amputee using sEMG based lower limb prostheses. Biocybernetics and Biomedical Engineering. https://doi.org/10.1016/j.bbe.2020.05.010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.