Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.

Imperceptive and reusable dermal surface EMG for lower extremity neuro-prosthetic control and clinical assessment

Open access

Abstract

Surface electromyography (sEMG) sensors play a critical role in diagnosing muscle conditions and enabling prosthetic device control, especially for lower extremity robotic legs. However, challenges arise when utilizing such sensors on residual limbs within a silicon liner worn by amputees, where dynamic pressure, narrow space, and perspiration can negatively affect sensor performance. Existing commercial sEMG sensors and newly developed sensors are unsuitable due to size and thickness, or susceptible to damage in this environment. In this paper, our sEMG sensors are tailored for amputees wearing sockets, prioritizing breathability, durability, and reliable recording performance. By employing porous PDMS and Silbione substrates, our design achieves exceptional permeability and adhesive properties. The serpentine electrode pattern and design are optimized to improve stretchability, durability, and effective contact area, resulting in a higher signal-to-noise ratio (SNR) than conventional electrodes. Notably, our proposed sensors wirelessly enable to control of a robotic leg for amputees, demonstrating its practical feasibility and expecting to drive forward neuro-prosthetic control in the clinical research field near future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41528-023-00282-z

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Schematic illustration of the fl exible and stretchable sEMG sensors designed for amputees. a sEMG sensor attached to different types of muscles in the legs. The red boxes show graphically implemented images, and the blue box presents a picture of the fabricated sEMG sensor. b Muscle parts are activated at different times depending on the gait phase. c Speci fi c description of the electrode layer and base layer of the sEMG sensor. Cross-sectional photographs of the electrode layer and substrate layer were obtained by scanning electron microscopy (SEM) and a microscope. The yellow dotted line indicates the boundary of each side. d Microscopically photographed surfaces of P-PDMS according to the citric acid concentration (scale bar, 1 mm). e Graph for the breathability test of P-PDMS ( e , n = 20 samples for WVTR, and n = 3 samples for thickness, data presented as mean ± s.d.). f Graph of the stress-strain curve of the substrate layer. The calculated tensile stress is 253.85 kPa, and Young ' s modulus is 145.38 kPa.
Fig. 1 Schematic illustration of the fl exible and stretchable sEMG sensors designed for amputees. a sEMG sensor attached to different types of muscles in the legs. The red boxes show graphically implemented images, and the blue box presents a picture of the fabricated sEMG sensor. b Muscle parts are activated at different times depending on the gait phase. c Speci fi c description of the electrode layer and base layer of the sEMG sensor. Cross-sectional photographs of the electrode layer and substrate layer were obtained by scanning electron microscopy (SEM) and a microscope. The yellow dotted line indicates the boundary of each side. d Microscopically photographed surfaces of P-PDMS according to the citric acid concentration (scale bar, 1 mm). e Graph for the breathability test of P-PDMS ( e , n = 20 samples for WVTR, and n = 3 samples for thickness, data presented as mean ± s.d.). f Graph of the stress-strain curve of the substrate layer. The calculated tensile stress is 253.85 kPa, and Young ' s modulus is 145.38 kPa.CC-BY · From the PDF
Fig. 2 Design and mechanical characteristics of the proposed sEMG electrodes. a Design of unit patterns forming the electrodes. The red dotted box shows the smallest part of the pattern. b Stress-strain curve graph of patterns calculated based on the numerical analysis simulation tool. The red arrow points in the direction of tension. c Description of single electrode designs with three density patterns . d Graph measuring the changes in the resistance according to the tensile strain of the device. Both sides of the substrate layer were fi xed with a clamp of the equipment, and the substrate was stretched in the direction of one clamp. The resistance meter was connected to the black dot to observe the amount of resistance change.
Fig. 2 Design and mechanical characteristics of the proposed sEMG electrodes. a Design of unit patterns forming the electrodes. The red dotted box shows the smallest part of the pattern. b Stress-strain curve graph of patterns calculated based on the numerical analysis simulation tool. The red arrow points in the direction of tension. c Description of single electrode designs with three density patterns . d Graph measuring the changes in the resistance according to the tensile strain of the device. Both sides of the substrate layer were fi xed with a clamp of the equipment, and the substrate was stretched in the direction of one clamp. The resistance meter was connected to the black dot to observe the amount of resistance change.CC-BY · From the PDF
Fig. 3 SNR comparison by pattern density for biceps. a Commercial electrodes and EMG sensors of various pattern densities were attached to the subject ' s biceps. The red box represents the electrodes used as sensing electrodes, and the black box represents the ground electrode. The subject repeated muscle contraction and relaxation for a certain period. b Muscle signals measured from the biceps. The legend represents what kind of electrodes were used. c SNR calculated from muscle signals measured from each electrode pair ( c , n = 3 trials, data presented as mean ± s.d.). d Sensitivity test graph measured using NSE as the sensing electrode and LG as the ground electrode.
Fig. 3 SNR comparison by pattern density for biceps. a Commercial electrodes and EMG sensors of various pattern densities were attached to the subject ' s biceps. The red box represents the electrodes used as sensing electrodes, and the black box represents the ground electrode. The subject repeated muscle contraction and relaxation for a certain period. b Muscle signals measured from the biceps. The legend represents what kind of electrodes were used. c SNR calculated from muscle signals measured from each electrode pair ( c , n = 3 trials, data presented as mean ± s.d.). d Sensitivity test graph measured using NSE as the sensing electrode and LG as the ground electrode.CC-BY · From the PDF
Image 4
CC-BY · From the PDF
Fig. 5 Clinical trial of leg amputees. a Attachment of the proposed sEMG to the amputee ' s TA and GC muscles. The red box represents the electrodes used as sensing electrodes, and the black box represents the ground electrode. The subject repeated muscle contraction and relaxation for a certain period. b Muscle signals measured from the patient. The red and blue signals were obtained from electrodes attached to the TA and GC muscles, respectively. The top is the raw EMG signal, and the bottom is the normalized EMG signal. c SNR calculated from muscle signals measured from the dorsi fl exion and the plantar fl exion, respectively ( c , n = 3 trials, each electrode, data presented as mean±s.d.). d Muscle signal for dorsi fl exion to drive the robot. e Demonstration of the wireless EMG signal acquisition system for the amputee ' s VM and VL muscles. f Wireless recorded EMG signals measured from the VL and VM muscles. g Setting method and photograph of wired and wireless systems for robot operation. Fig 5
Fig. 5 Clinical trial of leg amputees. a Attachment of the proposed sEMG to the amputee ' s TA and GC muscles. The red box represents the electrodes used as sensing electrodes, and the black box represents the ground electrode. The subject repeated muscle contraction and relaxation for a certain period. b Muscle signals measured from the patient. The red and blue signals were obtained from electrodes attached to the TA and GC muscles, respectively. The top is the raw EMG signal, and the bottom is the normalized EMG signal. c SNR calculated from muscle signals measured from the dorsi fl exion and the plantar fl exion, respectively ( c , n = 3 trials, each electrode, data presented as mean±s.d.). d Muscle signal for dorsi fl exion to drive the robot. e Demonstration of the wireless EMG signal acquisition system for the amputee ' s VM and VL muscles. f Wireless recorded EMG signals measured from the VL and VM muscles. g Setting method and photograph of wired and wireless systems for robot operation. Fig 5CC-BY · From the PDF
Image 6
CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 49 references

Research works printed but not linked: 4

  1. Bonnefoy-Mazure, A. & Armand, S. Normal gait. Orthop. Manag. Child. Cereb. Palsy 40, 567 (2015).
  2. Yoon, S., Seok, M., Kim, M. & Cho, Y.-H. Wearable porous PDMS layer of high moisture permeability for skin trouble reduction. Sci. Rep. 11, 938 (2021).
  3. Stegeman, D. & Hermens, H. Standards for surface electromyography: the European project Surface EMG for non-invasive assessment of muscles (SENIAM). Enschede Roessingh Res. Dev. 10, 8–12 (2007).
  4. Kalra, A., Lowe, A. & Al-Jumaily, A. Mechanical behaviour of skin: a review. J. Mater. Sci. Eng. 5, 1000254 (2016).

Cited by

See all 30

Metadata

Authors
Park, J., Jeong, J., Kang, M., Pritish, N., Cho, Y., Ha, J., Yea, J., Jang, K.-I., Kim, H., Hwang, J., Kim, B., Min, S., Kim, H., Kwon, S., Pak, C. J., Suh, H. P., Hong, J. P., & Lee, S.
Affiliations
  • Daegu Gyeongbuk Institute of Science and Technology (KR)
  • Asan Medical Center (KR)
  • Kwangwoon University (KR)
Corresponding author
Lee, Sanghoon
Venue
npj Flexible Electronics
Published
2023-10-25
Volume
7
Issue
1
ISSN
2397-4621 (ISSN-L)
OpenAlex
W4388266007
Cited by
30
References
49
Citations by year
2026: 12 · 2025: 11 · 2024: 7
FWCI
2.37
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Flexible Electronics (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Korea Medical Device Development Fund (1711135031)
  • Ministry of Trade, Industry and Energy
  • Ministry of Food and Drug Safety (1711135031)
  • Ministry of Science and ICT, South Korea
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
amputees, residual limb, serpentine electrodes, stretchable electrodes, wireless sensors, signal-to-noise ratio, sensor durability, breathability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imperceptive and reusable dermal surface EMG for lower extremity neuro-prosthetic control and clinical assessment. https://app.cochat.ai/papers/10.1038/s41528-023-00282-z
The paper
Park, J., Jeong, J., Kang, M., Pritish, N., Cho, Y., Ha, J., Yea, J., Jang, K.-I., Kim, H., Hwang, J., Kim, B., Min, S., Kim, H., Kwon, S., Pak, C. J., Suh, H. P., Hong, J. P., & Lee, S. (2023). Imperceptive and reusable dermal surface EMG for lower extremity neuro-prosthetic control and clinical assessment. npj Flexible Electronics. https://doi.org/10.1038/s41528-023-00282-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.