Methods to determine limit of detection and limit of quantification in quantitative real-time PCR (qPCR)
Open accessAbstract
Quantitative Real-Time Polymerase Chain Reaction, better known as qPCR, is the most sensitive and specific technique we have for the detection of nucleic acids. Even though it has been around for more than 30 years and is preferred in research applications, it has yet to win broad acceptance in routine practice. This requires a means to unambiguously assess the performance of specific qPCR analyses. Here we present methods to determine the limit of detection (LoD) and the limit of quantification (LoQ) as applicable to qPCR. These are based on standard statistical methods as recommended by regulatory bodies adapted to qPCR and complemented with a novel approach to estimate the precision of LoD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303 · cited 2×
“This non-linear system of equations is solved by GenEx 6 [11], using a quasi-Newton method.”
BackgroundMethodSelf-citationProcedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105 · cited 1×
“Grubb's test [13] was used to identify nine outliers that were removed, leaving 759 data points for the analysis.”
MethodBetter Bootstrap Confidence Intervals
Efron, B. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478410 · Cited by 3,364
Shrivastava, A., & Gupta, V. (2011) · Chronicles of Young Scientists · doi:10.4103/2229-5186.79345 · Cited by 3,205
Log-normal distributions across the sciences: keys and clues
LIMPERT, E., STAHEL, W. A., & ABBT, M. (2001) · BioScience · doi:10.1641/0006-3568(2001)051[0341:lndats]2.0.co;2 · Cited by 2,621
Park, H., Harris, S. M., Boldenow, E., Aronoff, D. M., Rea, M., Xi, C., & Loch‐Caruso, R. (2024) · American Journal of Reproductive Immunology · doi:10.1111/aji.13807 · Cited by 2,087
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Self-citationModelling the limit of detection in real-time quantitative PCR
Burns, M., & Valdivia, H. (2008) · European Food Research and Technology · doi:10.1007/s00217-007-0683-z · Cited by 181 · cited 1×
“LoD for qPCR methods can be estimated from analysis of replicate standard curves [10].”
MethodNutz, S., Döll, K., & Karlovský, P. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5089-x · Cited by 130
Correction of RT–qPCR data for genomic DNA-derived signals with ValidPrime
Laurell, H., Iacovoni, J. S., Abot, A., Švec, D., Maoret, J.-J., Arnal, J., & Kubista, M. (2012) · Nucleic Acids Research · doi:10.1093/nar/gkr1259 · Cited by 125
Self-citationRemoval of between-run variation in a multi-plate qPCR experiment
Ruijter, J. M., Villalba, A. R., Hellemans, J., Untergasser, A., & van den Hoff, M. J. B. (2015) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2015.07.001 · Cited by 117
More Accurate Confidence Intervals in Exponential Families
DiCiccio, T. J., & Efron, B. (1992) · Biometrika · doi:10.1093/biomet/79.2.231 · Cited by 113
The workflow of single-cell expression profiling using quantitative real-time PCR
Ståhlberg, A., & Kubista, M. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.901154 · Cited by 88
Self-citationBias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data
Tellinghuisen, J., & Spiess, A.-N. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02057 · Cited by 35
Tellinghuisen, J., & Spiess, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00077 · Cited by 20
The Evaluation of Statistical Methods for Estimating the Lower Limit of Detection
Huang, S., Wang, T., & Yang, M. (2012) · Assay and Drug Development Technologies · doi:10.1089/adt.2011.438 · Cited by 14
Cited by
The Ultimate qPCR Experiment: Producing Publication Quality, Reproducible Data the First Time
Taylor, S. C., Nadeau, K., Abbasi, M., Lachance, C., Nguyen, M., & Fenrich, J. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.12.002 · Cited by 830
Reporting the limits of detection and quantification for environmental DNA assays
Klymus, K. E., Merkes, C. M., Allison, M. J., Goldberg, C. S., Helbing, C. C., Hunter, M. E., Jackson, C. A., Lance, R. F., Mangan, A. M., Monroe, E. M., et al. (2020) · Environmental DNA · doi:10.1002/edn3.29 · Cited by 582
PCR inhibition in qPCR, dPCR and MPS—mechanisms and solutions
Sidstedt, M., Rådström, P., & Hedman, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02490-2 · Cited by 397
Bustin, S., & Huggett, J. (2017) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2017.11.001 · Cited by 312
Biosensors for rapid detection of bacterial pathogens in water, food and environment
Nnachi, R. C., Sui, N., Ke, B., Luo, Z., Bhalla, N., He, D., & Yang, Z. (2022) · Environment International · doi:10.1016/j.envint.2022.107357 · Cited by 297
Metadata
- Authors
- Forootan, A., Sjöback, R., Björkman, J., Sjögreen, B., Linz, L., & Kubista, M.
- Venue
- Biomolecular Detection and Quantification
- Publisher
- Elsevier BV
- Published
- 2017-06
- Volume
- 12
- Pages
- 1-6
- ISSN
- 2214-7535 (ISSN-L)
- OpenAlex
- W2608363029
- Cited by
- 578
- References
- 16
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.