CoChat

Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data

Tellinghuisen, Joel, Spiess, Andrej-Nikolai · 2015 · Analytical Chemistry

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Monte Carlo simulations are used to examine the bias and loss of precision that result from experimental error and analysis procedures in real-time quantitative polymerase chain reaction (PCR). In the limit of small copy numbers (N0), Poisson statistics govern the dispersion in estimates of the quantification cycle (Cq) for replicate experiments, permitting the estimation of N0 from the Cq variance, which is inversely proportional to N0. We derive corrections to expressions given previously for this determination. With increasing N0, the Poisson contribution decreases and other effects, like pipet volume uncertainty (typically >3%), dominate. Cycle-to-cycle variability in the amplification efficiency E produces scale dispersion similar to that for variability in the sensitivity of fluorescence detection. When this E variability is proportional to just the amplification (E - 1), there is insignificant effect on Cq if scale-independent definitions are used for this marker. Single-reaction analysis methods based on the exponential growth equation are inherently low-biased in E and high-biased in N0, and these biases can amount to factor-of-4 or greater error in N0. For estimating Cq, their greatest limitation is use of a constant absolute threshold, making them inefficient for data that exhibit scale variability.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b02057

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 36 references

Research works printed but not linked: 4

  1. Morrison T. B., 1998, BioTechniques, 24, 954
  2. 10.2144/3702a0246 · doi:10.2144/3702a0246
  3. Press W. H., 1986, Numerical Recipes
  4. Curry J. D., 2002, Mol. Biol. Today, 3, 79

Cited by

See all 36

Metadata

Authors
Tellinghuisen, J., & Spiess, A.-N.
Affiliations
  • Vanderbilt University (US)
  • University Medical Center Hamburg-Eppendorf (DE)
Corresponding author
Tellinghuisen, Joel
Venue
Analytical Chemistry
Published
2015-08-13
Volume
87
Issue
17
Pages
8925-8931
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2412182458
Cited by
35
References
36
Citations by year
2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 5 · 2020: 6 · 2019: 2 · 2017: 5 · 2016: 5 · 2015: 1
FWCI
1.59
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Deutsche Forschungsgemeinschaft (Sp721/4-1)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
Keywords
real-time quantitative PCR, Poisson statistics, fluorescence detection sensitivity, exponential growth model, absolute threshold, Monte Carlo simulation, bias and precision

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data. https://app.cochat.ai/papers/10.1021/acs.analchem.5b02057
The paper
Tellinghuisen, J., & Spiess, A.-N. (2015). Bias and Imprecision in Analysis of Real-Time Quantitative Polymerase Chain Reaction Data. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b02057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.