The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Advances in coatings on magnesium alloys for cardiovascular stents – A review
Open accessAbstract
Magnesium (Mg) and its alloys, as potential biodegradable materials, have drawn wide attention in the cardiovascular stent field because of their appropriate mechanical properties and biocompatibility. Nevertheless, the occurrence of thrombosis, inflammation, and restenosis of implanted Mg alloy stents caused by their poor corrosion resistance and insufficient endothelialization restrains their anticipated clinical applications. Numerous surface treatment tactics have mainly striven to modify the Mg alloy for inhibiting its degradation rate and enduing it with biological functionality. This review focuses on highlighting and summarizing the latest research progress in functionalized coatings on Mg alloys for cardiovascular stents over the last decade, regarding preparation strategies for metal oxide, metal hydroxide, inorganic nonmetallic, polymer, and their composite coatings; and the performance of these strategies in regulating degradation behavior and biofunction. Potential research direction is also concisely discussed to help guide biological functionalized strategies and inspire further innovations. It is hoped that this review can give assistance to the surface modification of cardiovascular Mg-based stents and promote future advancements in this emerging research field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mussel-inspired surface chemistry for multifunctional coatings
Lee, H., Dellatore, S. M., Miller, W. M., & Messersmith, P. B. (2007) · Science · doi:10.1126/science.1147241 · Cited by 10,965
Zhang, Y., Xu, J., Ruan, Y. C., Yu, M. K., O'Laughlin, M., Wise, H., Chen, D., Tian, L., Shi, D., Wang, J., et al. (2016) · Nature Medicine · doi:10.1038/nm.4162 · Cited by 1,051
Advances in functionalized polymer coatings on biodegradable magnesium alloys–A review
Li, L.-Y., Cui, L.-Y., Zeng, R.-C., Li, S.-Q., Chen, X.-B., Zheng, Y., & Kannan, M. B. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.030 · Cited by 466 · cited 1×
“During the service of implanted Mg-based stents, the coating composed of inorganic substances may not be able to play the expected protective role [142].”
BackgroundSelf-citationBall, V., Frari, D. D., Toniazzo, V., & Ruch, D. (2012) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2012.07.030 · Cited by 404
Adherence to healthy lifestyle and cardiovascular diseases in the Chinese population
Lv, J., Yu, C., Guo, Y., Bian, Z., Yang, L., Chen, Y., Tang, X., Zhang, W., Qian, Y., Huang, Y., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.076 · Cited by 266
Self-citationThe Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Rakoch, A. G., Monakhova, E. P., Khabibullina, Z. V., Serdechnova, M., Blawert, C., Zheludkevich, M. L., & Gladkova, A. A. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.06.002 · Cited by 134 · cited 1×
“Magnesium dioxide (MgO) coatings MAO refers to a novel technology for in-situ growth of ceramic oxide film on a valve’s metal surface (Al, Mg, Ti, and their alloys) [92,93].”
BackgroundCorrosion properties of polydopamine coatings formed in one-step immersion process on magnesium
Singer, F., Schlesak, M., Mebert, C., Höhn, S., & Virtanen, S. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b08760 · Cited by 128
Wei, Q., Li, B., Yi, N., Su, B., Yin, Z., Zhang, F., Li, J., & Zhao, C. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32956 · Cited by 113 · cited 1×
“Recently, many studies stated that PDA can be used as an intermediate layer for additional surface functionalization (to improve adhesion and biocompatibility) [185]; however, the blood compatibility of PDA coatings is very poor because the imino and quinine groups will rapidly adsorb proteins, thus leading to the occ…”
BackgroundSelf-citation
Cited by
Arif, Z. U., Khalid, M. Y., Noroozi, R., Sadeghianmaryan, A., Jalalvand, M., & Hossain, M. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.07.140 · Cited by 395
Applications of Magnesium and Its Alloys: A Review
Tan, J., & Ramakrishna, S. (2021) · Applied Sciences · doi:10.3390/app11156861 · Cited by 350
A review on magnesium alloys for biomedical applications
Zhang, T., Wang, W., Liu, J., Wang, L., Tang, Y., & Wang, K. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.953344 · Cited by 208
Wang, L., Xu, R., Meng, L., Zhang, Q., Qian, Z., Chen, J., & Pan, C. (2024) · Biomaterials Advances · doi:10.1016/j.bioadv.2024.213960 · Cited by 32
Jia, R., He, Y., Liang, J., Duan, L., Ma, C., Lu, T., Liu, W., Li, S., Wu, H., Cao, H., et al. (2024) · iScience · doi:10.1016/j.isci.2024.109197 · Cited by 14
Metadata
- Authors
- Zhang, Z.-Q., Yang, Y.-X., Li, J.-A., Zeng, R.-C., & Guan, S.-K.
- Venue
- Bioactive Materials
- Publisher
- Elsevier BV
- Published
- 2021-12
- Volume
- 6
- Issue
- 12
- Pages
- 4729-4757
- ISSN
- 2097-1192 (ISSN-L)
- 2452-199X
- OpenAlex
- W3165044882
- Cited by
- 173
- References
- 9
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.