Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation
Open accessAbstract
Little is known mechanistically about why implanted glucose sensors lag behind blood glucose levels in both the time to peak sensor response and the magnitude of peak sensor response. A mathematical model of glucose transport from capillaries through surrounding tissue to the sensor surface was constructed to address how different aspects of the tissue affect glucose transport to an implanted sensor. Physiologically relevant values of capsule diffusion coefficient, capsule porosity, cellular glucose consumption, capsule thickness, and subcutaneous vessel density were used as inputs to create simulated sensor traces that mimic experimental instances of time lag and concentration attenuation relative to a given blood glucose profile. Using logarithmic sensitivity analysis, each parameter was analyzed to study the effect of these variables on both lag and attenuation. Results identify capsule thickness as the strongest determinant of sensor time lag, while subcutaneous vessel density and capsule porosity had the largest effects on attenuation of glucose that reaches the sensor surface. These findings provide mechanistic insight for the rational design of sensor modifications that may alleviate the deleterious consequences of tissue effects on implanted sensor performance.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The thickness of the FBR was reduced to less than 100 μM, which could allow for enhanced diffusion of small molecules.
“Of potential clinical importance, the thickness of the FBR was reduced to less than 100 μM, which could allow for enhanced diffusion of small molecules (29).”
From Inflammasome components Asc and caspase-1 mediate biomaterial-induced inflammation and foreign body response (2011) · cites this paper as [29]
The Methods (Transport and kinetic parameters; page unavailable) use 75 μm as a typical capsule thickness in a model, not as a measured reduction of the foreign body response. The Results and Discussion (pages unavailable) indicate that thinner capsules shorten the time for glucose to reach a sensor, supporting the proposed transport benefit for glucose. The paper does not report that an intervention reduced FBR thickness below 100 μm or test small molecules generally. (LLM, conf=0.87)
Experimental — accuracy not yet measuredThese model results identify the histological parameters of key interest when assessing the biocompatibility of materials for glucose sensors.
“the results do identify the histological parameters of key interest when assessing the biocompatibility of materials for glucose sensors.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [111]
The two greatest factors in reducing sensor attenuation were low capsule density and a high degree of angiogenesis.
“The two greatest factors in reducing sensor attenuation were a low capsule density and high degree of angiogenesis.111”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [111]
In Novak and coworkers' model, changes in cellular glucose uptake and the capsule diffusion coefficient of glucose had little effect on simulated sensor performance.
“Changes in cellular glucose uptake and the capsule diffusion coefficient of glucose had little effect on simulated sensor performance.111”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [111]
The positive correlation between lag time and capsule thickness supported the models described above.
“The positive correlation between lag time and capsule thickness supported the models described above.107,110–111”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [111]
The Novak model concluded that collagen capsule thickness was the primary source of sensor lag time and had little impact on sensor response attenuation.
“The model was ultimately used to conclude that collagen capsule thickness, a common histological parameter, was the primary source of sensor lag time with little impact on sensor response attenuation.111”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [111]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · see citing works
Department of Health and Human Services
C.Miller, D., & J.Salkind, N. (2002) · Sage eBooks · doi:10.4135/9781412984386.n104 · Cited by 1,033 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Characterization of implantable biosensor membrane biofouling
Wisniewski, N. A., Moussy, F. G., & Reichert, W. M. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 351 · see citing works
Self-citationLong-term engraftment of hepatocytes transplanted on biodegradable polymer sponges
Mooney, D. J., Sano, K., Kaufmann, P. M., Majahod, K., Schloo, B. L., Vacanti, J. P., & Langer, R. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19971205)37:3 · Cited by 233 · see citing works
Concurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230 · see citing works
Application of Chronic Intravascular Blood Glucose Sensor in Dogs
Armour, J. C., Lucisano, J. Y., Bd, M., & Gough, D. A. (1990) · Diabetes · doi:10.2337/diab.39.12.1519 · Cited by 175 · see citing works
Quantification of information transfer via cellular signal transduction pathways
Kholodenko, B. Ν., Hoek, J. B., Westerhoff, H. V., & Brown, G. C. (1997) · FEBS Letters · doi:10.1016/s0014-5793(97)01018-1 · Cited by 166 · see citing works
Biomaterial–microvasculature interactions
Sieminski, A. L., & Gooch, K. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00149-6 · Cited by 155 · see citing works
Morphologic and hemodynamic comparison of tumor and healing normal tissue microvasculature
Dewhirst, M. W., Tso, C. Y., Oliver, R., Gustafson, C. S., Secomb, T. W., & Gross, J. F. (1989) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(89)90375-1 · Cited by 153 · see citing works
Implantable chemical sensors for real-time clinical monitoring: progress and challenges
Frost, M. C., & Meyerhoff, M. E. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00371-x · Cited by 148 · see citing works
von Recum, A. F. (1986) · Medical Entomology and Zoology · Cited by 134 · see citing works
Transvascular drug delivery in solid tumors
Fan, Y. (1998) · Seminars in Radiation Oncology · doi:10.1016/s1053-4296(98)80042-8 · Cited by 132 · see citing works
Norton, L. W., Koschwanez, H. E., Wisniewski, N. A., Klitzman, B., & Reichert, W. M. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31088 · Cited by 128 · see citing works
Self-citationWisniewski, N., Klitzman, B. M., Miller, B., & Reichert, W. M. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011215)57:4 · Cited by 120 · see citing works
Self-citationInfluence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89 · see citing works
Ahmed, N., Kansara, M., & Berridge, M. V. (1997) · Biochemical Journal · doi:10.1042/bj3270369 · Cited by 82 · see citing works
Koschwanez, H. E., Yap, F. Y., Klitzman, B., & Reichert, W. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31824 · Cited by 69 · see citing works
Self-citationContinuous Glucose Monitoring: An Overview of Its Development
Skyler, J. S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0045 · Cited by 63 · see citing works
Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo.
Updike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · PubMed · Cited by 57 · see citing works
Updike, S. J., Shults, M. C., Rhodes, R. K., GILLIGAN, B. J., LUEBOW, J. O., & von Heimburg, D. (1994) · ASAIO Journal · doi:10.1097/00002480-199404000-00007 · Cited by 52 · see citing works
Study of the effects of tissue reactions on the function of implanted glucose sensors
Dungel, P., Long, N., Yu, B., Moussy, Y., & Moussy, F. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31593 · Cited by 47 · see citing works
Winet, H., & Bao, J. Y. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980615)40:4 · Cited by 44 · see citing works
Insulin-stimulated glucose transport in human adipocytes.
Ciaraldi, T. P., Kolterman, O., Siegel, J. A., & Olefsky, J. M. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e621 · Cited by 41 · see citing works
An Investigation of Long-Term Performance of Minimally Invasive Glucose Biosensors
Yu, B., Ju, Y., West, L. A., Moussy, Y., & Moussy, F. G. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0020 · Cited by 35 · see citing works
The Future of Continuous Glucose Monitoring
Garg, S. K., & Aktürk, H. K. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0097 · Cited by 34 · see citing works
Treatment Issues in Type 1 Diabetes
Bloomgarden, Z. T. (2002) · Diabetes Care · doi:10.2337/diacare.25.1.230 · Cited by 18 · see citing works
Modeling the Response Time of an In Vivo Glucose Affinity Sensor
Clark, H. R., Barbari, T. A., & Rao, G. (1999) · Biotechnology Progress · doi:10.1021/bp990003j · Cited by 16 · see citing works
Ward, W. K., Wood, M. D., & Troupe, J. E. (2000) · ASAIO Journal · doi:10.1097/00002480-200009000-00006 · Cited by 13 · see citing works
The Future of Continuous Glucose Monitoring
Garg, S. K. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0105 · Cited by 10 · see citing works
Koschwanez, H. E. (2009) · DukeSpace (Duke University) · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
Malik, A. F., Hoque, R., Ouyang, X., Ghani, A., Hong, E., Khan, K., Moore, L. B., Ng, G., Munro, F., Flavell, R. A., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105152108 · Cited by 107 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants
Nichols, S. P., Koh, A., Brown, N. L., Rose, M. B., Sun, B., Slomberg, D. L., Riccio, D. A., Klitzman, B., & Schoenfisch, M. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.053 · Cited by 67 · see citing works
- Authors
- Novak, M. T., Yuan, F., & Reichert, W. M.
- Affiliations
- Duke University (US)
- Corresponding author
- Reichert, William M.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2010-08-28
- Volume
- 398
- Issue
- 4
- Pages
- 1695-1705
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- PMC
- PMC2966551
- OpenAlex
- W2092269870
- Cited by
- 55
- References
- 32
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 4 · 2018: 5 · 2017: 4 · 2016: 4 · 2015: 7 · 2014: 5 · 2013: 6 · 2012: 3
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of General Medical Sciences (T32GM008555, T32 GM-8555)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK54932, R01DK054932, R56DK054932)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Keywords
- signal attenuation, subcutaneous tissue, capsule thickness, diffusion coefficient, sensitivity analysis, sensor design
- MeSH terms
- Animals, Biological Transport, Diffusion, Glucose, Kinetics, Models, Biological, Biosensing Techniques, Prostheses and Implants, Rats, Microvessels
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review