The effect of crystallinity on the deformation mechanism and bulk mechanical properties of PLLA
Abstract
Poly (l-lactide) is a widely studied biomaterial, currently approved for use in a range of medical devices, however, most in vitro studies have so far focussed upon either the bulk properties during degradation and/or deformation, or on the microstructure of the unloaded material during degradation. This study aimed to combine these approaches through the technique of simultaneous small-angle X-ray scattering and tensile testing at various stages of degradation up to 8 months, on material with a range of induced microstructures. Results showed that the amorphous material deformed by crazing in the dry, wet and degraded states, however, the mechanism by which the craze developed changed significantly on hydration. Despite this difference, there was little change in the bulk mechanical properties. Crystalline materials deformed through crystal-mediated deformation, with contributions from both cavitation and fibrillated shear, but surprisingly, differences in the length scales within the spherulitic structure caused by annealing at different temperatures had very little effect on the mechanism of deformation, though differences were seen in the bulk properties. Furthermore, hydration had little effect on the crystalline materials, though degradation over 8 months resulted in loss of mechanical properties for samples produced at higher annealing temperatures. In conclusion, the introduction of crystallinity had a huge effect on both bulk and microscopic properties of PLLA, but the spherulitic structure of the crystalline material affected the bulk properties significantly more than it did the micromechanism of deformation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The subsequent reduction in T g upon hydration can be attributed to water absorption and plasticisation, as water molecules diffuse between polymer chains, increasing free volume and reducing inter-chain bonding [40-43].”
From Tuning structural relaxations, mechanical properties, and degradation timescale of PLLA during hydrolytic degradation by blending with PLCL-PEG (2019) · cites this paper as [43]
Citations
Cites
Fischer, E. W., Sterzel, H. J., & Wegner, G. (1973) · Kolloid-Zeitschrift und Zeitschrift für Polymere · doi:10.1007/bf01498927 · Cited by 1,704
Fischer, E. W., Sterzel, H. J., & Wegner, G. (1973) · Aktuelle Probleme der Polymer-Physik · doi:10.1007/978-3-642-47050-9_24 · Cited by 683
Strength and toughness of crystalline polymer systems
Gałęski, A. (2003) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2003.09.003 · Cited by 619
Thermal and mechanical properties of plasticized poly(L‐lactic acid)
Baiardo, M., Frisoni, G., Scandola, M., Rimelen, M., Lips, D., Ruffieux, K., & Wintermantel, E. (2003) · Journal of Applied Polymer Science · doi:10.1002/app.12549 · Cited by 568
Tsuji, H. (1995) · Polymer · doi:10.1016/0032-3861(95)93647-5 · Cited by 531
Li, S., Garreau, H., & Vert, M. (1990) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00701077 · Cited by 496
Tsuji, H., & Ikada, Y. (2000) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(99)00111-1 · Cited by 329
Further investigations on the hydrolytic degradation of poly (DL-lactide)
Li, S., & McCarthy, S. (1999) · Biomaterials · doi:10.1016/s0142-9612(97)00226-3 · Cited by 301
Bioabsorption of polylactides with different molecular properties
Nakamura, T., Hitomï, S., Watanabe, S., Shimizu, Y., Jamshidi, K., Hyon, S. H., & Ikada, Y. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231003 · Cited by 244
Craze microstructure from small-angle x-ray scattering (SAXS)
Brown, H. R., & Kramer, E. J. (1981) · Journal of Macromolecular Science Part B · doi:10.1080/00222348108015315 · Cited by 166
Research works printed but not linked: 2
- Kohn J, Langer R. Biresorbable and bioerodable materials. In: Ratner BD, Hoffman AS, Schoen FJ, Lemons JE, editors. Biomaterials science, an introduction to materials science. San Diego: Academic Press; 1996.
- Tsuji, 1997, Blends of crystalline and amorphous poly(lactide) III, Hydrolysis of solution-cast blend films. J Appl Polym Sci, 63, 855
Cited by
Sorted by citations
Bai, H., Xiu, H., Gao, J., Deng, H., Zhang, Q., Yang, M., & Fu, Q. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am201564f · Cited by 260
A phenomenological model for the degradation of biodegradable polymers
Wang, Y., Pan, J., Han, X., Sinka, C., & Ding, L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.042 · Cited by 191
“Another factor that complicates the biodegradation is that the degree of crystallinity often increases significantly during the degradation [11,12].”
BackgroundOstafinska, A., Fortelny, I., Nevoralova, M., Hodan, J., Kredatusova, J., & Slouf, M. (2015) · RSC Advances · doi:10.1039/c5ra21178f · Cited by 176
Sébastien, F., Grelier, S., Copinet, A., & Coma, V. (2006) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2006.01.006 · Cited by 179
Bai, H., Huang, C., Xiu, H., Gao, Y., Zhang, Q., & Fu, Q. (2013) · Polymer · doi:10.1016/j.polymer.2013.07.051 · Cited by 153
Effect of annealing and orientation on microstructures and mechanical properties of polylactic acid
Yu, L. F., Liu, H., Xie, F., Chen, L., & Li, X. (2008) · Polymer Engineering and Science · doi:10.1002/pen.20970 · Cited by 151
Kanehashi, S., Kusakabe, A., Satō, S., & Nagai, K. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.08.035 · Cited by 141
Bai, L., Zhao, X., Bao, R., Liu, Z., Yang, M., & Yang, W. M. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-2306-4 · Cited by 138
“The crystallinity was determined from the fractional area of the crystalline peaks to the total area [46].”
BackgroundLong‐Term Absorption of Poly‐L‐Lactic Acid Interference Screws
Barber, F. A., & Dockery, W. D. (2006) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2006.04.096 · Cited by 137
Reactive Compatibilization of Polylactide/Polypropylene Blends
Xu, Y., Loi, J., Delgado, P. C., Topolkaraev, V. A., McEneany, R. J., Macosko, C. W., & Hillmyer, M. A. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b00882 · Cited by 124
Na, B., Zhu, J., Lv, R., Ju, Y., Tian, R., & Chen, B. (2013) · Macromolecules · doi:10.1021/ma402405c · Cited by 119
Tough Polylactide Graft Copolymers
Theryo, G., Jing, F., Pitet, L. M., & Hillmyer, M. A. (2010) · Macromolecules · doi:10.1021/ma101155p · Cited by 119
Oksiuta, Z., Jałbrzykowski, M., Mystkowska, J., Romańczuk-Ruszuk, E., & Osiecki, T. (2020) · Polymers · doi:10.3390/polym12122939 · Cited by 114
“The relatively rapid decrease in the mechanical properties of PLA-based composites can be explained by two phenomena: (1) the initially rapid hydration at the polymer-reinforcing phase boundary breaking the bond between the matrix and reinforcement and the local stress concentration that inhibits the transfer of appli…”
BackgroundXie, M., Wang, L., Guo, B., Wang, Z., Chen, Y., & Ma, P. X. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.042 · Cited by 112
Crystallization of Poly( l -lactic acid) Probed with Dielectric Relaxation Spectroscopy
Brás, A. R. E., Viciosa, M. T., Wang, Y., Dionísio, M. S., & Mano, J. F. (2006) · Macromolecules · doi:10.1021/ma061148r · Cited by 110
Zhang, X., Schneider, K., Liu, G., Chen, J., Brüning, K., Wang, D., & Stamm, M. (2011) · Polymer · doi:10.1016/j.polymer.2011.07.003 · Cited by 108
Cold crystallization and postmelting crystallization of PLA plasticized by compressed carbon dioxide
Yu, L. F., Liu, H., Dean, K., & Chen, L. (2008) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.21599 · Cited by 103
Influence of Semicrystalline Morphology on the Glass Transition of Poly(L‐lactic acid)
Wang, Y., Funari, S. S., & Mano, J. F. (2006) · Macromolecular Chemistry and Physics · doi:10.1002/macp.200600114 · Cited by 104
In-situ SAXS study of the plastic deformation behavior of polylactide upon cold-drawing
Stoclet, G., Lefebvre, J. M., Séguéla, R., & Vanmansart, C. (2014) · Polymer · doi:10.1016/j.polymer.2014.02.010 · Cited by 87
Effect of Silica Nanoparticles on the Mechanical Performances of Poly(Lactic Acid)
Dorigato, A., Sebastiani, M., Pegoretti, A., & Fambri, L. (2012) · Journal of Polymers and the Environment · doi:10.1007/s10924-012-0425-6 · Cited by 87
Zhang, X., Schneider, K., Liu, G., Chen, J., Brüning, K., Wang, D., & Stamm, M. (2011) · Polymer · doi:10.1016/j.polymer.2011.12.002 · Cited by 82
Fujisawa, S., Saito, T., Kimura, S., Iwata, T., & Isogai, A. (2013) · Composites Science and Technology · doi:10.1016/j.compscitech.2013.10.021 · Cited by 69
Brás, A. R. E., Malik, P., Dionísio, M. S., & Mano, J. F. (2008) · Macromolecules · doi:10.1021/ma800842a · Cited by 65
Effect of the Recycling and Annealing on the Mechanical and Fracture Properties of Poly(Lactic Acid)
Nascimento, L., Gámez‐Pérez, J., Pérez, O. O. S., Velasco, J. I., Maspoch, M. L., & Urquiza, E. A. F. (2010) · Journal of Polymers and the Environment · doi:10.1007/s10924-010-0229-5 · Cited by 68
Leroy, A., Ribeiro, S., Grossiord, C., Alves, A., Vestberg, R., Salles, V., Brunon, C., Gritsch, K., Grosgogeat, B., & Bayon, Y. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5894-7 · Cited by 66
Xu, H., Liu, C., Chen, C., Hsiao, B. S., Zhong, G., & Li, Z. (2012) · Biopolymers · doi:10.1002/bip.22079 · Cited by 62
Dilemma and breakthrough of biodegradable poly-l-lactic acid in bone tissue repair
Zan, J., Qian, G., Deng, F., Zhang, J., Zeng, Z., Peng, S., & Shuai, C. (2022) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2022.01.164 · Cited by 61
Bitinis, N., Sanz, A., Nogales, A., Verdejo, R., López-Manchado, M. Á., & Ezquerra, T. A. (2012) · Soft Matter · doi:10.1039/c2sm25729g · Cited by 56
Yao, S., Hu, D., Xi, Z., Liu, T., Xu, Z., & Zhao, L. (2020) · Polymer Testing · doi:10.1016/j.polymertesting.2020.106649 · Cited by 52
Meriçer, Ç., Minelli, M., Angelis, M. G. D., Baschetti, M. G., Stancampiano, A., Laurita, R., Gherardi, M., Colombo, V., Trifol, J., Szabó, P., et al. (2016) · Industrial Crops and Products · doi:10.1016/j.indcrop.2016.03.020 · Cited by 49
Multiplicity of morphologies in poly ( l -lactide) bioresorbable vascular scaffolds
Ailianou, A., Ramachandran, K., Kossuth, M. B., Oberhauser, J. P., & Kornfield, J. A. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1602311113 · Cited by 50
“Scaffold deployment in the arteries occurs in aqueous media, for which the scant literature reports a strain at break of PLLA less than 10% (23).”
BackgroundPerego, G., & Cella, G. D. (2010) · Wiley eBooks · doi:10.1002/9780470649848.ch11 · Cited by 54
Enhanced ductility of polylactide materials: Reactive blending with pre-hot sheared natural rubber
Zhang, C., Huang, Y., Luo, C., Jiang, L., & Dan, Y. (2013) · Journal of Polymer Research · doi:10.1007/s10965-013-0121-9 · Cited by 48
“3 %, which was similar to a reported literature value for amorphous poly(L-lactide) [23].”
BackgroundResultSpectroscopy techniques for analyzing the hydrolysis of PLGA and PLLA
Tan, H. Y., Widjaja, E., Boey, F., & Loo, S. C. J. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31419 · Cited by 44
Accelerated ageing and degradation in poly-l-lactide/hydroxyapatite nanocomposites
Delabarde, C., Plummer, C. J. G., Bourban, P. ‐., & Månson, J. E. (2011) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2010.12.018 · Cited by 42
Progress on Medical Implant: A Review and Prospects
Pandey, A., & Sahoo, S. (2022) · Journal of Bionic Engineering · doi:10.1007/s42235-022-00284-z · Cited by 41
Rheology, Mechanical Properties, and Barrier Properties of Poly(lactic acid)
Domenek, S., Nassar, S. F., & Ducruet, V. (2017) · Advances in polymer science · doi:10.1007/12_2016_17 · Cited by 42
Effect of Accelerated Weathering on Physico-Mechanical Properties of Polylactide Bio-Composites
Sawpan, M. A., Islam, M. R., Beg, M. D. H., & Pickering, K. L. (2019) · Journal of Polymers and the Environment · doi:10.1007/s10924-019-01405-2 · Cited by 40
Heeley, E. L., Billimoria, K., Parsons, N., Figiel, Ł., Keating, E. M., Cafolla, C. T., Crabb, E. M., & Hughes, D. J. (2020) · Polymer · doi:10.1016/j.polymer.2020.122353 · Cited by 40
“Renouf-Glauser et al [26] looked at the uniaxial deformation of both amorphous and annealed PLLA using small-angle X-scattering (SAXS).”
MethodNaseem, R., Zhao, L., Liu, Y., & Silberschmidt, V. V. (2017) · Mechanics of Advanced Materials and Modern Processes · doi:10.1186/s40759-017-0028-y · Cited by 36
“This process was found to have a significant effect on mechanical properties of PLLA samples where, generally, a higher annealing temperature resulted in a polymer with higher crystallinity and a more ordered crystalline phase (Renouf-Glauser et al. 2005; Welch et al. 2008).”
BackgroundDegradation of Aliphatic Polyesters in the Presence of Inorganic Fillers
Chouzouri, G., & Xanthos, M. (2007) · Journal of Plastic Film & Sheeting · doi:10.1177/8756087907076599 · Cited by 36
Wang, F., Shen, Y., Xu, X., Lv, L., Li, Y., Liu, J., Li, M., Guo, A., Guo, S., & Jin, F. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.08.008 · Cited by 35
Poly(l-lactic acid) monofilaments for biodegradable braided self-expanding stent
Zhao, G., Li, X., Tian, Y., Wu, G., Zhang, Y., Jiang, W., Yang, J., & Ni, Z. (2021) · Journal of Materials Science · doi:10.1007/s10853-021-06021-x · Cited by 35
“In addition, considering that the braided stents need to be annealed to fix the shapes, it is necessary to investigate the effect of the annealing on the properties of the monofilaments [33].”
BackgroundDeng, H., Yu, J., Liu, C., Zhao, Y., Pan, H., Ni, H., Wang, Z., Bian, J., Han, L., & Zhang, H. (2023) · Thermochimica Acta · doi:10.1016/j.tca.2023.179628 · Cited by 34
Cellulose nanofibrils as templates for the design of poly(l-lactide)-nucleating surfaces
Fujisawa, S., Zhang, J., Saito, T., Iwata, T., & Isogai, A. (2014) · Polymer · doi:10.1016/j.polymer.2014.04.019 · Cited by 34
A multi-scale method for modeling degradation of bioresorbable polyesters
Zhang, T., Zhou, S., Xiaohao, G., Yang, Z., Leran, S., & Zhang, D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.12.046 · Cited by 34
Khan, K. A., & El-Sayed, T. (2012) · Acta Mechanica · doi:10.1007/s00707-012-0760-7 · Cited by 33
“For example, the mechanical response of nondegraded PLLA was characterized by [1,17,41], Miller and Williams [29] and Soares [46] under different loading conditions.”
Development of biodegradable PLA/PBT nanoblends
Santos, L. G. R. A., Costa, L., & Pessan, L. A. (2017) · Journal of Applied Polymer Science · doi:10.1002/app.45951 · Cited by 32
Lorenzo, M. L. D., Ovyn, R., Malinconico, M., Rubino, P., & Grohens, Y. (2015) · Polymer Engineering and Science · doi:10.1002/pen.24058 · Cited by 33
Wilberforce, S. I. J., Finlayson, C. E., Best, S. M., & Cameron, R. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.02.006 · Cited by 32
Bai, L., Zhang, Z., Pu, J., Feng, C., Zhao, X., Bao, R., Liu, Z., Yang, M., & Yang, W. M. (2020) · Polymer · doi:10.1016/j.polymer.2020.122390 · Cited by 32
Oosterbeek, R. N., Kwon, K.-A., Duffy, P., McMahon, S., Zhang, X. C., Best, S. M., & Cameron, R. E. (2019) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2019.109015 · Cited by 30
“The subsequent reduction in Tg upon hydration can be attributed to water absorption and plasticisation, as water molecules diffuse between polymer chains, increasing free volume and reducing inter-chain bonding [40–43].”
BackgroundHan, L., Han, C., & Dong, L. (2012) · Polymer International · doi:10.1002/pi.4300 · Cited by 30
Constitutive modeling for biodegradable polymers for application in endovascular stents
Soares, D. S., & Filipe, J. D. P. D. C. (2008) · Cited by 28
Odent, J., Raquez, J., Leclère, P. E. L. G., Lauro, F., & Dúbois, P. (2015) · Polymers for Advanced Technologies · doi:10.1002/pat.3513 · Cited by 28
Effects of fatigue on the chemical and mechanical degradation of model stent sub-units
Dreher, M. L., Nagaraja, S., & Batchelor, B. L. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.12.020 · Cited by 28
Poly( l ‐Lactic Acid) Nanofiber‐Based Multilayer Film for the Electrical Stimulation of Nerve Cells
Jiang, F., Shan, Y., Tian, J., Xu, L., Chao-hai, L., Yu, F., Cui, X. J., Wang, C., Li, Z., & Ren, K. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202474 · Cited by 27
Comparison of the effects of Mg–6Zn and titanium on intestinal tract in vivo
Yan, J. F., Chen, Y., Yuan, Q., Yu, S., Qiu, W.-C., Yang, C.-G., Wang, Z., Gong, J., Ai, K., Zheng, Q., et al. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-4906-5 · Cited by 27
Finniss, A., Agarwal, S., & Gupta, R. K. (2016) · Journal of Applied Polymer Science · doi:10.1002/app.44166 · Cited by 27
Rasal, R. M., Bohannon, B. G., & Hirt, D. E. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30980 · Cited by 29
Fiuza, C., Polak-Kraśna, K., Antonini, L., Petrini, L., Carroll, O., Ronan, W., & Vaughan, T. J. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104955 · Cited by 25
The influence of thermal treatment on the mechanical characteristics of a PLLA coiled stent
Welch, T. R., Eberhart, R. C., & Chuong, C. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31286 · Cited by 24
Wang, X.-H., Ni, J.-S., Cao, N.-L., Yu, S., Chen, Y.-G., Zhang, S.-X., Gu, B.-J., & Yan, J. F. (2017) · Scientific Reports · doi:10.1038/srep44919 · Cited by 24
High performance poly (lactic acid)/bio-polyamide11 through controlled chain mobility
Heshmati, V., & Favis, B. D. (2017) · Polymer · doi:10.1016/j.polymer.2017.07.009 · Cited by 24
Jia, L., Zhang, W., Tong, B., & Yang, R. (2018) · Journal of Applied Polymer Science · doi:10.1002/app.46982 · Cited by 24
Influence of Annealing and Biaxial Expansion on the Properties of Poly(l-Lactic Acid) Medical Tubing
Dillon, B., Doran, P., Fuenmayor, E., Healy, A. V., Gately, N. M., Major, I., & Lyons, J. G. (2019) · Polymers · doi:10.3390/polym11071172 · Cited by 26
Kobielarz, M., Gazińska, M., Tomanik, M., Stępak, B., Szustakiewicz, K., Filipiak, J., Antończak, A. J., & Pezowicz, C. (2019) · Polymer degradation and stability · doi:10.1016/j.polymdegradstab.2019.05.010 · Cited by 17
Pérez, O. O. S., Rodríguez, C., Belzunce, F. J., Gámez‐Pérez, J., Carrasco, F., & Maspoch, M. L. (2010) · Polymer Testing · doi:10.1016/j.polymertesting.2010.09.004 · Cited by 21
Li, Y., Xu, X., Shen, Y.-Y., Qian, C., Lu, F., & Guo, S.-R. (2013) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2013.03.043 · Cited by 20
Ramachandran, K., Luccio, T. D., Ailianou, A., Kossuth, M. B., Oberhauser, J. P., & Kornfield, J. A. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1807347115 · Cited by 20
“S1 A and B), which is associated with scission of “tie chains” that connect lamellar crystals and provide load-bearing capability to the polymer (19, 32).”
BackgroundLaser-modified PLGA for implants: in vitro degradation and mechanical properties
Kobielarz, M., Tomanik, M., Mroczkowska, K., Szustakiewicz, K., Oryszczak, M., Mazur, A., Antończak, A. J., & Filipiak, J. (2020) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb-01532-2019-02 · Cited by 20
Yan, J., Chen, Y., Yuan, Q., Wang, X., Yu, S., Qiu, W.-C., Wang, Z., Ai, K., Zhang, X., Zhang, S., et al. (2014) · Biomedical Materials · doi:10.1088/1748-6041/9/2/025011 · Cited by 20
Silk fibroin and sericin: Multifunctional formulations for treating diabetic wound healing
Bogadi, S., Malayandi, R., Palanimuthu, V. R., Anandasadagopan, S. K., Parvathaneni, M., Kundu, M. K., Islam, M. R., Khan, F. S., Tagde, P., Mondal, T. K., et al. (2024) · European Polymer Journal · doi:10.1016/j.eurpolymj.2024.113465 · Cited by 19
Performance of latexes containing nano-sized crystalline domains formed by comb-like polymers
Mehravar, E., Leiza, J. R., & Asúa, J. M. (2016) · Polymer · doi:10.1016/j.polymer.2016.04.067 · Cited by 19
The Kinetics of Melting Crystallization of Poly-L-Lactide
Zhi-hua, Z., Ruan, J., Zhongcheng, Z., & Jian-peng, Z. (2007) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602550701279994 · Cited by 19
Highly Toughened Polylactide‐Based Materials through Melt‐Blending Techniques
Odent, J., Raquez, J., & Dúbois, P. (2015) · Wiley eBooks · doi:10.1002/9783527656950.ch10 · Cited by 20
Jia, S., Han, L., Chen, Y., Pan, H., Wang, X., Zhang, H., Dong, L., & Zhang, H. (2022) · Polymer · doi:10.1016/j.polymer.2022.125143 · Cited by 18
Role of Dicumyl Peroxide on Toughening PLLA via Dynamic Vulcanization
Liu, L., Hou, J., Wang, L., Zhang, J., & Duan, Y. (2016) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.6b02122 · Cited by 18
Largely improved tensile extensibility of poly( L ‐lactic acid) by adding poly(ε‐caprolactone)
Chen, L., Yang, J., Wang, K., Chen, F., & Fu, Q. (2010) · Polymer International · doi:10.1002/pi.2843 · Cited by 18
Ramachandran, K., Miscioscia, R., Filippo, G., Pandolfi, G., Luccio, T. D., & Kornfield, J. A. (2018) · Polymers · doi:10.3390/polym10030288 · Cited by 17
“However, PLLA is notorious for being a brittle polymer [12,13],”
BackgroundAho, J., Halme, A., Boetker, J. P., Water, J. J., Bohr, A., Sandler, N., Rantanen, J., & Baldursdóttir, S. (2017) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2017.08.135 · Cited by 16
Suwantong, O., Pankongadisak, P., Deachathai, S., & Supaphol, P. (2012) · Journal of Polymer Research · doi:10.1007/s10965-012-9896-3 · Cited by 15
Müller, K., Opdenbosch, D. V., & Zollfrank, C. (2021) · Materials Today Communications · doi:10.1016/j.mtcomm.2021.103074 · Cited by 15
Crystallinity and mechanical properties of polylactide/ether‐amide copolymer blends
Jauzein, T., Huneault, M. A., & Heuzey, M. (2016) · Journal of Applied Polymer Science · doi:10.1002/app.44677 · Cited by 15
Kassos, N., Kelly, A. L., Gough, T. D., & Gill, A. A. (2018) · Materials Research Express · doi:10.1088/2053-1591/aaf7c1 · Cited by 15
Shear yielding and crazing in dry and wet amorphous PLA at body temperature
Chen, H., Pan, Z., Yuan, D., Sulley, G. S., Oosterbeek, R. N., Williams, C. K., & Brassart, L. (2023) · Polymer · doi:10.1016/j.polymer.2023.126477 · Cited by 14
Odent, J., Raquez, J., Thomassin, J., Gloaguen, J. M., Lauro, F., Jérôme, C., Lefebvre, J., & Dúbois, P. (2015) · Nanocomposites · doi:10.1179/2055033215y.0000000005 · Cited by 14
Takehara, H., Hadano, Y., Kanda, Y., & Ichiki, T. (2020) · Micromachines · doi:10.3390/mi11050452 · Cited by 15
“The mechanism of the deformation of the amorphous and crystalline PLLA polymers indicates that the amorphous region could be deformed by crazing, and the crystalline region could show cavitation and fibrillated shear [12].”
BackgroundZin, S. H. M., Velayutham, T. S., Furukawa, T., Kodama, H., Gan, W. C., Chio‐Srichan, S., Kriechbaum, M., & Nakajima, T. (2022) · Polymer · doi:10.1016/j.polymer.2022.125095 · Cited by 14
Petisco-Ferrero, S., Etxeberria, A., & Sarasua, J.-R. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.04.003 · Cited by 14
Dillon, B., Doran, P., Fuenmayor, E. A., Healy, A. V., Gately, N., Major, I., & Lyons, J. G. (2019) · Polymers · doi:10.3390/polym11040710 · Cited by 14
“Crystallinity also plays an important role in determining the materials thermal and mechanical properties, as well as its degradation rate [8,9].”
BackgroundEffect of Laser-Induced Crystallinity Modification on Biodegradation Profile of Poly(L-Lactic Acid)
Hsu, S., Tan, H., & Yao, Y. L. (2013) · Journal of Manufacturing Science and Engineering · doi:10.1115/1.4025394 · Cited by 13
“Another factor that complicates biodegradation is the increase of crystallinity during degradation [6,7].”
BackgroundCifuentes, S. C., Cifuentes, S. C., Benavente, R., Lieblich, M., González-Carrasco, J. L., & González-Carrasco, J. L. (2017) · Handbook of Composites from Renewable Materials · doi:10.1002/9781119441632.ch88 · Cited by 13
Development of a flow evolution network model for the stress-strain behavior of poly(L-lactide)
Dreher, M. L., Nagaraja, S., Bergstrom, J., & Hayman, D. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4037071 · Cited by 12
Mahalakshmi, S., Alagesan, T., Parthasarathy, V., Tung, K., & Anbarasan, R. (2019) · Journal of Polymer Research · doi:10.1007/s10965-019-1789-2 · Cited by 12
Kanda, Y., Takehara, H., & Ichiki, T. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab0ff6 · Cited by 13
The effect of thermal treatment on the mechanical properties of PLLA tubular specimens
Arbeiter, D., Schümann, K., Sahmel, O., Eickner, T., Schmitz, K., & Grabow, N. (2016) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2016-0009 · Cited by 12
A high-performance degradable Mg alloy suturing staple for single-arm oral stapling robot
Wang, Q., Liang, S., Yuan, F. S., Liu, B., Yu, J., Wang, W., Fakhar, N., & Li, H. X. (2023) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2023.06.009 · Cited by 11
Takehara, H., Inada, M., Kanda, Y., & Ichiki, T. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.106885 · Cited by 10
Borůvka, M., Cermak, C., Běhálek, L., & Brdlik, P. M. (2021) · Polymers · doi:10.3390/polym13162835 · Cited by 10
“On the other hand, in crystalline PLLA, deformation under impact loading takes place through the deformation of the crystallites with the contribution of cavitation and fibrillation mechanisms [51].”
Background
Metadata
- Authors
- Renouf-Glauser, A. C., Rose, J., Farrar, D. F., & Cameron, R. E.
- Affiliations
- University of Cambridge (GB)
- Smith & Nephew (United Kingdom) (GB)
- Corresponding author
- Cameron, Ruth Elizabeth
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2005-10
- Volume
- 26
- Issue
- 29
- Pages
- 5771-5782
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2075491047
- Cited by
- 153
- References
- 26
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 6 · 2023: 6 · 2022: 8 · 2021: 6 · 2020: 9 · 2019: 9 · 2018: 8 · 2017: 12 · 2016: 12 · 2015: 8 · 2014: 8 · 2013: 10 · 2012: 8
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Smith and Nephew
- Engineering and Physical Sciences Research Council
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- poly(L-lactic acid), crystallinity, deformation mechanisms, bulk mechanical properties, polymer degradation, crazing, spherulitic structure, annealing temperature, hydration, cavitation
- MeSH terms
- Biocompatible Materials, Fourier Analysis, Materials Testing, Polyesters, Polymers, Scattering, Radiation, Stress, Mechanical, Temperature, Tensile Strength, Time Factors, Water, X-Ray Diffraction, X-Rays, Crystallography, X-Ray, Lactic Acid, Absorbable Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review