The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
The in vivo degradation, absorption and excretion of PCL-based implant
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Pharmaceutical Excipients
Rowe, R. C., Sheskey, P. J., & Quinn, M. E. (1994) · Cited by 3,493
Mechanisms and Kinetics of Thermal Degradation of Poly(ε-caprolactone)
Persenaire, O., Alexandre, M., Degée, P., & Dubois, P. (2001) · Biomacromolecules · doi:10.1021/bm0056310 · Cited by 444
The intracellular degradation of poly(ε‐caprolactone)
Woodward, S. C., Brewer, P. S., Moatamed, F., Schindler, A., & Pitt, C. G. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190408 · Cited by 380
Polycaprolactone microparticles and their biodegradation
Chen, D. R., Bei, J. Z., & Wang, S. G. (2000) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(99)00145-7 · Cited by 316
Mechanisms of polymer degradation in implantable devices
Ali, S. A. M., Zhong, S.-P., Doherty, P. J., & Williams, D. F. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90063-8 · Cited by 208
Clinical evaluation of the Capronor contraceptive implant: Preliminary report
Darney, P. D., Monroe, S. E., Klaisle, C., & Alvarado, A. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(89)80015-8 · Cited by 126
Thermal degradation of poly (ε-caprolactone)
Sivalingam, G., & Madras, G. (2003) · Polymer Degradation and Stability · doi:10.1016/s0141-3910(02)00376-2 · Cited by 109
Enzymatic and Thermal Degradation of Poly(ε-caprolactone), Poly( d , l -lactide), and Their Blends
Sivalingam, G., Vijayalakshmi, S. P., & Madras, G. (2004) · Industrial & Engineering Chemistry Research · doi:10.1021/ie049589r · Cited by 91
Conaway, C. C., Jiao, D., Kohri, T., Liebes, L., & Chung, F. (1999) · Drug Metabolism and Disposition · doi:10.1016/s0090-9556(24)14877-5 · Cited by 72
Recent developments in hormone delivery systems
SHULMAN, L. P., Nelson, A. L., & Darney, P. D. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.01.064 · Cited by 37
Capronor--a biodegradable delivery system for levonorgestrel.
Pitt, C. G., & Schindler, A. K. (1984) · Cited by 31
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
A 3D bioprinting system to produce human-scale tissue constructs with structural integrity
Kang, H.-W., Lee, S. J., Ko, I. K., Kengla, C., Yoo, J. J., & Atala, A. (2016) · Nature Biotechnology · doi:10.1038/nbt.3413 · Cited by 2,622
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Bone tissue engineering: A review in bone biomimetics and drug delivery strategies
Porter, J. R., Ruckh, T. T., & Popat, K. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.246 · Cited by 809
Metadata
- Authors
- Sun, H., Mei, L., Song, C., Cui, X., & Wang, P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-03
- Volume
- 27
- Issue
- 9
- Pages
- 1735-1740
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2032032896
- Cited by
- 976
- References
- 11
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.