The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Framework for optimal design of porous scaffold microstructure by computational simulation of bone regeneration
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Self-citationFused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Self-citationTissue-engineered bone regeneration
Petite, H., Viateau, V., Bensaïd, W., Meunier, A., de Pollak, C., Bourguignon, M., Oudina, K., Sedel, L., & Guillemin, G. (2000) · Nature Biotechnology · doi:10.1038/79449 · Cited by 1,475
Hutmacher, D. W. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201744489 · Cited by 1,409
Organ printing: computer-aided jet-based 3D tissue engineering
Mironov, V., Boland, T., Trusk, T., Forgacs, G., & Markwald, R. R. (2003) · Trends in Biotechnology · doi:10.1016/s0167-7799(03)00033-7 · Cited by 1,276
Adaptive bone-remodeling theory applied to prosthetic-design analysis
Huiskes, R., Weinans, H., Grootenboer, H. J., Dalstra, M., Fudala, B., & Slooff, T. J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90030-3 · Cited by 1,173
Hutmacher, D. W., Sittinger, M., & Risbud, M. V. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.05.005 · Cited by 1,121
Cited by
Three-Dimensional Cell Culture Matrices: State of the Art
Lee, J., Cuddihy, M. J., & Kotov, N. A. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/teb.2007.0150 · Cited by 1,047
Current trends in the design of scaffolds for computer-aided tissue engineering
Giannitelli, S. M., Accoto, D., Trombetta, M., & Rainer, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.024 · Cited by 451
Scaffold Design and Manufacturing: From Concept to Clinic
Hollister, S. J. (2009) · Advanced Materials · doi:10.1002/adma.200802977 · Cited by 408
Self-citationDesign, Materials, and Mechanobiology of Biodegradable Scaffolds for Bone Tissue Engineering
Velasco, M. A., Narváez-Tovar, C. A., & Garzón-Alvarado, D. A. (2015) · BioMed Research International · doi:10.1155/2015/729076 · Cited by 395
Byrne, D. P., Lacroix, D., Planell, J. A., Kelly, D. J., & Prendergast, P. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.09.003 · Cited by 362
Metadata
- Authors
- Adachi, T., Osako, Y., Tanaka, M., Hojo, M., & Hollister, S. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2006-07
- Volume
- 27
- Issue
- 21
- Pages
- 3964-3972
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1992957889
- Cited by
- 316
- References
- 50
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Framework for optimal design of porous scaffold microstructure by computational simulation of bone regeneration. https://app.cochat.ai/papers/10.1016/j.biomaterials.2006.02.039
- The paper
- Adachi, T., Osako, Y., Tanaka, M., Hojo, M., & Hollister, S. J. (2006). Framework for optimal design of porous scaffold microstructure by computational simulation of bone regeneration. Biomaterials. https://doi.org/10.1016/j.biomaterials.2006.02.039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.