The correlation of pore morphology, interconnectivity and physical properties of 3D ceramic scaffolds with bone ingrowth
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Flow of gases through porous media
Carman, P. C. (1956) · Medical Entomology and Zoology · Cited by 2,815
Third-Generation Biomedical Materials
Hench, L. L., & Polak, J. M. (2002) · Science · doi:10.1126/science.1067404 · Cited by 2,789
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hutmacher, D. W. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201744489 · Cited by 1,409
Self-citationFlow of gases through porous media
Eisenklam, P. (1957) · Combustion and Flame · doi:10.1016/0010-2180(57)90038-x · Cited by 1,362
Bones: Structure and Mechanics
Currey, J. D. (2002) · Cited by 1,125
Mechanotransduction and the functional response of bone to mechanical strain
Duncan, R. L., & Turner, C. H. (1995) · Calcified Tissue International · doi:10.1007/bf00302070 · Cited by 1,048
Martys, N. S., & Chen, H. (1996) · Physical Review E · doi:10.1103/physreve.53.743 · Cited by 892
Evaluated Material Properties for a Sintered alpha‐Alumina
Munro, R. G. (1997) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1997.tb03074.x · Cited by 836
Application of porous ceramics for the attachment of load bearing internal orthopedic applications
Klawitter, J. J., & Hulbert, S. F. (1971) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820050613 · Cited by 634
Role of interconnections in porous bioceramics on bone recolonization in vitro and in vivo
LU, J. X., FLAUTRE, B., ANSELME, K., HARDOUIN, P., GALLUR, A., DESCAMPS, M., & THIERRY, B. (1999) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008973120918 · Cited by 530
Saito, T., & Toriwaki, J. (1994) · Pattern Recognition · doi:10.1016/0031-3203(94)90133-3 · Cited by 529
Pore-morphology-based simulation of drainage in totally wetting porous media
Hilpert, M., & Miller, C. T. (2001) · Advances in Water Resources · doi:10.1016/s0309-1708(00)00056-7 · Cited by 438
Internal plate fixation of fractures: short history and recent developments
Uhthoff, H. K., Poitras, P., & Backman, D. S. (2006) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0984-7 · Cited by 438
Assessment of bone ingrowth into porous biomaterials using MICRO-CT
Jones, A. C., Arns, C. H., Sheppard, A. P., Hutmacher, D. W., Milthorpe, B. K., & Knackstedt, M. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.046 · Cited by 422
Self-citationTissue reaction to three ceramics of porous and non‐porous structures
Hulbert, S. F., Morrison, S. J., & Klawitter, J. J. (1972) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820060505 · Cited by 421
Distance-Ordered Homotopic Thinning: A Skeletonization Algorithm for 3D Digital Images
Pudney, C. J. (1998) · Computer Vision and Image Understanding · doi:10.1006/cviu.1998.0680 · Cited by 361
3-D computational modeling of media flow through scaffolds in a perfusion bioreactor
Porter, B., Zauel, R., Stockman, H., Guldberg, R., & Fyhrie, D. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.011 · Cited by 339
Frontiers in Tissue Engineering: In Vitro Modulation of Chondrogenesis
Freed, L. E., Martin, I., & Vunjak-Novakovic, G. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199910001-00006 · Cited by 285
Bones: Structure and mechanics
Marzke, M. W. (2003) · American Journal of Human Biology · doi:10.1002/ajhb.10145 · Cited by 266
Frontiers in Tissue Engineering
(1998) · Elsevier eBooks · doi:10.1016/b978-0-08-042689-1.x5001-8 · Cited by 258
Universal scaling of fluid permeability for sphere packings
Martys, N., Salvatore Torquato, A., & Bentz, D. P. (1994) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.50.403 · Cited by 239
Effect of porosity on the fluid flow characteristics and mechanical properties of tantalum scaffolds
Shimko, D. A., Shimko, V. F., Sander, E. A., Dickson, K. F., & Nauman, E. A. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30229 · Cited by 215
Moore, M. J., Jabbari, E., Ritman, E. L., Lu, L., Currier, B. L., Windebank, A. J., & Yaszemski, M. J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30138 · Cited by 161
Mechanics considerations for microporous titanium as an orthopedic implant material
Thelen, S., Barthelat, F., & Brinson, L. C. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.20100 · Cited by 158
Micro-finite element models of bone tissue-engineering scaffolds
Lacroix, D. J., Chateau, A., Ginebra, M., & Planell, J. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.009 · Cited by 142
Fluid conductance of cancellous bone graft as a predictor for graft-host interface healing
Hui, P. W., Leung, P., & Sher, A. H. L. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00010-0 · Cited by 127
Designing porous scaffolds for tissue engineering
Bonfield, W. (2006) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2005.1692 · Cited by 114
Trabecular bone scaffolding using a biomimetic approach
Cleynenbreugel, T. V., Oosterwyck, H. V., Sloten, J. V., & Schrooten, J. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1021183230549 · Cited by 35
Tissue Engineered Construct Design Principles
Reece, G. P., & Patrick, C. (1998) · Elsevier eBooks · doi:10.1016/b978-008042689-1/50012-1 · Cited by 18
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Recent advances in bioprinting techniques: approaches, applications and future prospects
Li, J., Chen, M., Fan, X., & Zhou, H. (2016) · Journal of Translational Medicine · doi:10.1186/s12967-016-1028-0 · Cited by 608
Arabnejad, S., Burnett Johnston, R., Pura, J. A., Singh, B., Tanzer, M., & Pasini, D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.10.048 · Cited by 578
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Self-citationDepartment of Tissue Regeneration, U. O. T., Barradas, A., Yuan, H., van Blitterswijk, C., & Habibovic, P. (2011) · European Cells and Materials · doi:10.22203/ecm.v021a31 · Cited by 518
Metadata
- Authors
- Jones, A. C., Arns, C. H., Hutmacher, D. W., Milthorpe, B. K., Sheppard, A. P., & Knackstedt, M. A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 30
- Issue
- 7
- Pages
- 1440-1451
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2161515689
- Cited by
- 346
- References
- 33
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.