The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The penetration of fresh undiluted sputum expectorated by cystic fibrosis patients by non-adhesive polymer nanoparticles
Open accessAbstract
Highly viscoelastic and adhesive sputum has precluded efficient nanoparticle-based drug and gene delivery to the lungs of patients with cystic fibrosis (CF). We sought to determine whether nanoparticles coated with non-mucoadhesive polymers could penetrate CF sputum, and to use these “muco-inert particles” (MIPs) as non-destructive nanoprobes to characterize the sputum microstructure. Particles as large as 200 nm in diameter that were densely coated with low MW polyethylene glycol (PEG) moved through undiluted CF sputum with average speeds up to 90-fold faster than similarly-sized uncoated particles. On the other hand, the transport of both coated and uncoated 500 nm particles was strongly hindered. The local viscosity of sputum, encountered by the fastest 10% of 200 nm MIPs, was only 5-fold higher than that of water, whereas the bulk viscosity was 10,000-fold higher at low shear rates. Using measured transport rates of various sized MIPs combined with an obstruction-scaling model, we determined that the average 3D mesh spacing of CF sputum is ~140 ± 50 nm (range: 60-300 nm). Taken together, these results demonstrate that nanoparticles up to 200 nm in diameter that do not adhere to CF sputum can move rapidly through this critical barrier by accessing pores that are filled with a low viscosity fluid. The results also offer hope that desperately needed sputum-penetrating drug- and gene-carrier nanoparticles can be developed for CF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid transport of large polymeric nanoparticles in fresh undiluted human mucus
Lai, S. K., O'Hanlon, D. E., Harrold, S., Man, S. T., Wang, Y.-Y., Cone, R., & Hanes, J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608611104 · Cited by 1,050
Self-citation
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
Self-citationBiomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Oral drug delivery with polymeric nanoparticles: The gastrointestinal mucus barriers
Ensign, L. M., Cone, R., & Hanes, J. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.12.009 · Cited by 1,623
Self-citationMicro- and macrorheology of mucus
Lai, S. K., Wang, Y.-Y., Wirtz, D., & Hanes, J. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.09.012 · Cited by 1,223
Self-citationXu, Q., Ensign, L. M., Boylan, N. J., Schön, A., Gong, X., Yang, J.-C., Lamb, N. W., Cai, S., Yu, T., Freire, E., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b03876 · Cited by 568
Self-citation
Metadata
- Authors
- Suk, J. S., Lai, S. K., Wang, Y.-Y., Ensign, L. M., Zeitlin, P. L., Boyle, M. P., & Hanes, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 30
- Issue
- 13
- Pages
- 2591-2597
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2087154016
- Cited by
- 352
- References
- 1
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The penetration of fresh undiluted sputum expectorated by cystic fibrosis patients by non-adhesive polymer nanoparticles. https://app.cochat.ai/papers/10.1016/j.biomaterials.2008.12.076
- The paper
- Suk, J. S., Lai, S. K., Wang, Y.-Y., Ensign, L. M., Zeitlin, P. L., Boyle, M. P., & Hanes, J. (2009). The penetration of fresh undiluted sputum expectorated by cystic fibrosis patients by non-adhesive polymer nanoparticles. Biomaterials. https://doi.org/10.1016/j.biomaterials.2008.12.076
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.