Engineering retinal progenitor cell and scrollable poly(glycerol-sebacate) composites for expansion and subretinal transplantation
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Retinal degenerations cause permanent visual loss and affect millions world-wide. Presently, a novel treatment highlights the potential of using biodegradable polymer scaffolds to induce differentiation and deliver retinal progenitor cells for cell replacement therapy. In this study, we engineered and analyzed a micro-fabricated polymer, poly(glycerol sebacate) (PGS) scaffold, whose useful properties include biocompatibility, elasticity, porosity, and a microtopology conducive to mouse retinal progenitor cell (mRPC) differentiation. In vitro proliferation assays revealed that PGS held up to 86,610 (±9993) mRPCs per square millimeter, which were retained through simulated transplantations. mRPCs adherent to PGS differentiated toward mature phenotypes as evidenced by changes in mRNA, protein levels, and enhanced sensitivity to glutamate. Transplanted composites demonstrated long-term mRPC survival and migrated cells exhibited mature marker expression in host retina. These results suggest that combining mRPCs with PGS scaffolds for subretinal transplantation is a practical strategy for advancing retinal tissue engineering as a restorative therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of synthetic micro- and nano-structured surfaces on cell behavior
Flemming, R. G., Murphy, C. J., Abrams, G. A., Goodman, S. L., & Nealey, P. F. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00209-9 · Cited by 1,450 · cited 1×
“Polymer topology influenced differentiation is predicted to progress via cell binding to nano and microscale features followed by cell surface receptors acting as mechanochemical transducers, activating signal transduction pathways and ultimately modulating gene expression and protein expression [30].”
BackgroundRetinal repair by transplantation of photoreceptor precursors
MacLaren, R. E., Pearson, R. A., MacNeil, A., Douglas, R. H., Salt, T. E., Akimoto, M., Swaroop, A., Sowden, J. C., & Ali, R. R. (2006) · Nature · doi:10.1038/nature05161 · Cited by 1,096 · cited 3×
“While the adult mammalian retina does not spontaneously regenerate, studies have shown that retinal tissue can be replaced and some degree of functional recovery regained following the delivery of RPCs to the subretinal space [2,3].”
BackgroundInfluentialReview: tissue engineering for regeneration of articular cartilage
Temenoff, J. S., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00213-6 · Cited by 1,052 · cited 1×
“When cells are grown under the appropriate conditions on a threedimensional scaffold, they become capable of developing mature genetic expression patterns and morphology [11,12].”
BackgroundCell fate determination in the vertebrate retina.
Cepko, C. L., Austin, C. P., Yang, X., Alexiades, M., & Ezzeddine, D. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.2.589 · Cited by 986
Biomaterials in Drug Delivery and Tissue Engineering: One Laboratory's Experience
Langer, R. (2000) · Accounts of Chemical Research · doi:10.1021/ar9800993 · Cited by 750 · cited 3×
“In addition, the PGS gradually surface biodegrades through hydrolysis, reducing the chance of negatively affecting the pH of the subretinal microenvironment, as is common with bulk-degrading polymers like PLGA [9,15].”
BackgroundSelf-citationOsakada, F., Ikeda, H., Mandai, M., Wataya, T., Watanabe, K., Yoshimura, N., Akaike, A., Sasai, Y., & Takahashi, M. (2008) · Nature Biotechnology · doi:10.1038/nbt1384 · Cited by 633 · cited 1×
“5%) were shown to migrate into retina [3,38].”
BackgroundKrichevsky, A. M., & Kosik, K. S. (2001) · Neuron · doi:10.1016/s0896-6273(01)00508-6 · Cited by 536 · cited 1×
“This may be a reflection of decreased translation and consequent stockpiling of mRNA [21].”
BackgroundRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476 · cited 1×
“The rho / retinal phenotype is well characterized and retinal remodeling including glial hypertrophy and scarring occurs during loss of photoreceptor outer segments [22].”
BackgroundBiocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Sundback, C. A., Shyu, J. Y., Wang, Y., Faquin, W. C., Langer, R. S., Vacanti, J. P., & Hadlock, T. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.004 · Cited by 443 · cited 1×
“This microfabricated PGS scaffold is 45 mm thick with 50 mm diameter pores spaced 175 mm apart [9,16].”
MethodSelf-citationNanoscale features influence epithelial cell morphology and cytokine production
Andersson, A.-S., Bäckhed, F., von Euler, A., Richter-Dahlfors, A., Sutherland, D., & Kasemo, B. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00208-4 · Cited by 347 · cited 1×
“This observed cell behavior is supported by earlier findings describing the tendency of polymer topology to direct progenitor cellmorphologic adaptations and subsequent changes in protein expression levels [26,27–30].”
Result
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Photopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Renewable polymeric materials from vegetable oils: a perspective
Lligadas, G., Ronda, J. C., Galià, M., & Cádiz, V. (2013) · Materials Today · doi:10.1016/j.mattod.2013.08.016 · Cited by 559
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Regenerative Therapies for Central Nervous System Diseases: a Biomaterials Approach
Tam, R. Y., Fuehrmann, T., Mitrousis, N., & Shoichet, M. S. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2013.237 · Cited by 293
A hydrogel-based stem cell delivery system to treat retinal degenerative diseases
Ballios, B. G., Cooke, M. J., van der Kooy, D., & Shoichet, M. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.004 · Cited by 248
“Cell survival and proliferation were assessed separately in this study, a distinction that has been neglected in previous biomaterial-cell delivery studies [23,46].”
BackgroundPolyester elastomers for soft tissue engineering
Ye, H., Zhang, K., Kai, D., Li, Z., & Loh, X. J. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00161h · Cited by 238
Injectable hydrogels for central nervous system therapy
Pakulska, M. M., Ballios, B. G., & Shoichet, M. S. (2012) · Biomedical Materials · doi:10.1088/1748-6041/7/2/024101 · Cited by 216
“[125, 126], polycaprolactone (PCL) [127], and electrospun”
Liu, Q., Jiang, L., Shi, R., & Zhang, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.001 · Cited by 203
Gasparini, S. J., Llonch, S., Borsch, O., & Ader, M. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.11.001 · Cited by 186
Prevention of posterior capsular opacification
Nibourg, L. M., Gelens, E., Kuijer, R., Hooymans, J. M. M., van Kooten, T. G., & Koopmans, S. A. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2015.03.011 · Cited by 170
“In ophthalmology nanomaterials are currently examined for the use in retinal implants (Chen et al., 2011; Pritchard et al., 2010; Redenti et al., 2009), the development of artificial corneas (Bakhshandeh et al.”
BackgroundHybrid PGS-PCL microfibrous scaffolds with improved mechanical and biological properties
Sant, S., Hwang, C. M., Lee, S.-H., & Khademhosseini, A. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.313 · Cited by 162
“…(Wang et al., 2002) that has emerged as a promising scaffold material for tissue-engineering applications (Fidkowski et al., 2005; Sundback et al., 2005; Radisic et al., 2007, 2008; Chen et al., 2008; Engelmayr et al., 2008; Gao et al., 2008; Hacking and Khademhosseini, 2009; Redenti et al., 2009).”
Influential
Metadata
- Authors
- Redenti, S., Neeley, W. L., Rompani, S., Saigal, S., Yang, J., Klassen, H., Langer, R., & Young, M. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 30
- Issue
- 20
- Pages
- 3405-3414
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1488006786
- Cited by
- 176
- References
- 31
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.