The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Polyethylene glycol modified, cross-linked starch-coated iron oxide nanoparticles for enhanced magnetic tumor targeting
Open accessAbstract
While successful magnetic tumor targeting of iron oxide nanoparticles has been achieved in a number of models, the rapid blood clearance of magnetically suitable particles by the reticuloendothelial system (RES) limits their availability for targeting. This work aimed to develop a long-circulating magnetic iron oxide nanoparticle (MNP) platform capable of sustained tumor exposure via the circulation and, thus, potentially enhanced magnetic tumor targeting. Aminated, cross-linked starch (DN) and aminosilane (A) coated MNPs were successfully modified with 5 kDa (A5, D5) or 20 kDa (A20, D20) polyethylene glycol (PEG) chains using simple N-Hydroxysuccinimide (NHS) chemistry and characterized. Identical PEG-weight analogues between platforms (A5 & D5, A20 & D20) were similar in size (140-190 nm) and relative PEG labeling (1.5% of surface amines - A5/D5, 0.4% - A20/D20), with all PEG-MNPs possessing magnetization properties suitable for magnetic targeting. Candidate PEG-MNPs were studied in RES simulations in vitro to predict long-circulating character. D5 and D20 performed best showing sustained size stability in cell culture medium at 37 °C and 7 (D20) to 10 (D5) fold less uptake in RAW264.7 macrophages when compared to previously targeted, unmodified starch MNPs (D). Observations in vitro were validated in vivo, with D5 (7.29 h) and D20 (11.75 h) showing much longer half-lives than D (0.12 h). Improved plasma stability enhanced tumor MNP exposure 100 (D5) to 150 (D20) fold as measured by plasma AUC(0-∞). Sustained tumor exposure over 24 h was visually confirmed in a 9L-glioma rat model (12 mg Fe/kg) using magnetic resonance imaging (MRI). Findings indicate that a polyethylene glycol modified, cross-linked starch-coated MNP is a promising platform for enhanced magnetic tumor targeting, warranting further study in tumor models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Molecular weight and surface density of PEG coatings are two critical parameters that influence the dispersion stability, cytotoxicity and blood circulation time of iron oxide nanoparticles [71, 87].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [71]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,906
PHOTOMETRIC NINHYDRIN METHOD FOR USE IN THE CHROMATOGRAPHY OF AMINO ACIDS
Moore, S., & Stein, W. H. (1948) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)51034-6 · Cited by 3,035
Surface modification of superparamagnetic magnetite nanoparticles and their intracellular uptake
Zhang, Y., Kohler, N., & Zhang, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00267-8 · Cited by 1,266
Tumor-Selective Delivery of Macromolecular Drugs via the EPR Effect: Background and Future Prospects
Maeda, H. (2010) · Bioconjugate Chemistry · doi:10.1021/bc100070g · Cited by 997
Chertok, B., Moffat, B. A., David, A. E., Yu, F., Bergemann, C., Ross, B. D., & Yang, V. C.-M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.050 · Cited by 901
Self-citationMultifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892
Magnetic nanoparticles for drug delivery
Dobson, J. (2006) · Drug Development Research · doi:10.1002/ddr.20067 · Cited by 887
Magnetic nanoparticles for gene and drug delivery
Dobson, J. (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s1608 · Cited by 759
Xie, J., Xu, C., Kohler, N., Hou, Y., & Sun, S. (2007) · Advanced Materials · doi:10.1002/adma.200701975 · Cited by 686
Gene therapy progress and prospects: magnetic nanoparticle-based gene delivery
Dobson, J. (2006) · Gene Therapy · doi:10.1038/sj.gt.3302720 · Cited by 567
Cited by
Sorted by citations
Progress and challenges towards targeted delivery of cancer therapeutics
Rosenblum, D., Joshi, N., Tao, W., Karp, J. M., & Peer, D. (2018) · Nature Communications · doi:10.1038/s41467-018-03705-y · Cited by 2,220
Wu, W., Wu, Z., Yu, T., Jiang, C., & Kim, W.-S. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/2/023501 · Cited by 1,574
Biological applications of magnetic nanoparticles
Colombo, M., Carregal‐Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,340
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Superparamagnetic iron oxide nanoparticles: magnetic nanoplatforms as drug carriers
Wahajuddin, M., & Arora, S. (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30320 · Cited by 1,148
Metadata
- Authors
- Cole, A. J., David, A. E., Wang, J., Galbán, C. J., Hill, H. L., & Yang, V. C.
- Affiliations
- University of Michigan (US)
- Fudan University (CN)
- Tianjin University (CN)
- Corresponding author
- Yang, Victor C.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-03
- Volume
- 32
- Issue
- 8
- Pages
- 2183-2193
- ISSN
- 0142-9612 (ISSN-L)
- PMC
- PMC3022959
- OpenAlex
- W2029871153
- Cited by
- 308
- References
- 41
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 15 · 2023: 15 · 2022: 14 · 2021: 20 · 2020: 19 · 2019: 25 · 2018: 23 · 2017: 18 · 2016: 25 · 2015: 26 · 2014: 24 · 2013: 35 · 2012: 24
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (NIH) (CA114612, NS066945)
- Hartwell Foundation Biomedical Research Award
- WCU project (R31-2008-000-10103-01)
- NIGMS (GM007767)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
- Keywords
- iron oxide nanoparticles, polyethylene glycol coating, long-circulating nanoparticles, reticuloendothelial system clearance, macrophage uptake, glioma, MRI contrast agents
- MeSH terms
- Animals, Biocompatible Materials, Cell Line, Cross-Linking Reagents, Electron Spin Resonance Spectroscopy, Ferric Compounds, Macrophages, Magnetic Resonance Imaging, Magnetics, Male, Materials Testing, Neoplasms, Particle Size, Polyethylene Glycols, Rats, Inbred F344, Starch, Molecular Structure, Spectroscopy, Fourier Transform Infrared, Mice, Rats, Metal Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review