CoChat

Patterned cardiomyocytes on microelectrode arrays as a functional, high information content drug screening platform

Open access
Natarajan, Anupama, Stancescu, Maria, Dhir, Vipra, Armstrong, Christopher, Sommerhage, Frank, Hickman, James J., Molnar, Peter · 2011 · Biomaterials
Cited by 119

The DOI matches its Crossref record.

Abstract

Cardiac side effects are one of the major causes of drug candidate failures in preclinical drug development or in clinical trials and are responsible for the retraction of several already marketed therapeutics. Thus, the development of a relatively high-throughput, high-information content tool to screen drugs and toxins would be important in the field of cardiac research and drug development. In this study, recordings from commercial multielectrode arrays were combined with surface patterning of cardiac myocyte monolayers to enhance the information content of the method; specifically, to enable the measurement of conduction velocity, refractory period after action potentials and to create a functional reentry model. Two drugs, 1-Heptanol, a gap junction blocker, and Sparfloxacin, a fluoroquinone antibiotic, were tested in this system. 1-Heptanol administration resulted in a marked reduction in conduction velocity, whereas Sparfloxacin caused rapid, irregular and unsynchronized activity, indicating fibrillation. As shown in these experiments, patterning of cardiac myocyte monolayers solved several inherent problems of multielectrode recordings, increased the temporal resolution of conduction velocity measurements, and made the synchronization of external stimulation with action potential propagation possible for refractory period measurements. This method could be further developed as a cardiac side effect screening platform after combination with human cardiomyocytes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2010.12.022

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 119

Metadata

Authors
Natarajan, A., Stancescu, M., Dhir, V., Armstrong, C., Sommerhage, F., Hickman, J. J., & Molnar, P.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2011-06
Volume
32
Issue
18
Pages
4267-4274
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2080886982
Cited by
119
References
0
FWCI
5.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patterned cardiomyocytes on microelectrode arrays as a functional, high information content drug screening platform. https://app.cochat.ai/papers/10.1016/j.biomaterials.2010.12.022
The paper
Natarajan, A., Stancescu, M., Dhir, V., Armstrong, C., Sommerhage, F., Hickman, J. J., & Molnar, P. (2011). Patterned cardiomyocytes on microelectrode arrays as a functional, high information content drug screening platform. Biomaterials. https://doi.org/10.1016/j.biomaterials.2010.12.022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.