Patterned cardiomyocytes on microelectrode arrays as a functional, high information content drug screening platform
Open accessThe DOI matches its Crossref record.
Abstract
Cardiac side effects are one of the major causes of drug candidate failures in preclinical drug development or in clinical trials and are responsible for the retraction of several already marketed therapeutics. Thus, the development of a relatively high-throughput, high-information content tool to screen drugs and toxins would be important in the field of cardiac research and drug development. In this study, recordings from commercial multielectrode arrays were combined with surface patterning of cardiac myocyte monolayers to enhance the information content of the method; specifically, to enable the measurement of conduction velocity, refractory period after action potentials and to create a functional reentry model. Two drugs, 1-Heptanol, a gap junction blocker, and Sparfloxacin, a fluoroquinone antibiotic, were tested in this system. 1-Heptanol administration resulted in a marked reduction in conduction velocity, whereas Sparfloxacin caused rapid, irregular and unsynchronized activity, indicating fibrillation. As shown in these experiments, patterning of cardiac myocyte monolayers solved several inherent problems of multielectrode recordings, increased the temporal resolution of conduction velocity measurements, and made the synchronization of external stimulation with action potential propagation possible for refractory period measurements. This method could be further developed as a cardiac side effect screening platform after combination with human cardiomyocytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fetal Bovine Serum (FBS): past ‐ present ‐ future
van der Valk, J. (2018) · ALTEX · doi:10.14573/altex.1705101 · Cited by 481
Multi-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
Self-citationOrgan-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
Design and demonstration of a pumpless 14 compartment microphysiological system
Miller, P. G., & Shuler, M. L. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25989 · Cited by 238
Sung, J. H., Esch, M. B., Prot, J.-M., Long, C. J., Smith, A., Hickman, J. J., & Shuler, M. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41017j · Cited by 233
Self-citationCardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Dai, X., Zhou, W., Gao, T., Liu, J., & Lieber, C. M. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.96 · Cited by 202
Multi-organ system for the evaluation of efficacy and off-target toxicity of anticancer therapeutics
McAleer, C. W., Long, C. J., Elbrecht, D., Sasserath, T., Bridges, L. R., Rumsey, J. W., Martin, C., Schnepper, M., Wang, Y., Schuler, F., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav1386 · Cited by 199
Self-citationOleaga, C., Riu, A., Rothemund, S., Lavado, A., McAleer, C. W., Long, C. J., Persaud, K., Narasimhan, N. S., Tran, M., Roles, J., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.062 · Cited by 175
“Cryopreserved human iPSc derived cardiomyocytes (Cellular Dynamic International, CDI, Madison, WI, USA) were plated onto glass coverslips (400 cells/mm(2)), cMEA (1000 cells/mm(2)) or cantilevers (2,200 cells/mm(2)) with HSL2 medium [19, 24, 25] (Supplementary Table 1) and maintained for 7 days before assembly into th…”
InfluentialSelf-citationMultiorgan Microphysiological Systems for Drug Development: Strategies, Advances, and Challenges
Wang, Y. I., Carmona, C., Hickman, J. J., & Shuler, M. L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701000 · Cited by 167
Self-citationSelf-contained, low-cost Body-on-a-Chip systems for drug development
Wang, Y. I., Oleaga, C., Long, C. J., Esch, M. B., McAleer, C. W., Miller, P. G., Hickman, J. J., & Shuler, M. L. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217694101 · Cited by 59
Self-citation
Metadata
- Authors
- Natarajan, A., Stancescu, M., Dhir, V., Armstrong, C., Sommerhage, F., Hickman, J. J., & Molnar, P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-06
- Volume
- 32
- Issue
- 18
- Pages
- 4267-4274
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2080886982
- Cited by
- 119
- References
- 0
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.