NIR-light-induced surface-enhanced Raman scattering for detection and photothermal/photodynamic therapy of cancer cells using methylene blue-embedded gold nanorod@SiO2 nanocomposites
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Methylene blue-loaded gold nanorod@SiO2 (MB-GNR@SiO2) core@shell nanoparticles are synthesized for use in cancer imaging and photothermal/photodynamic dual therapy. For the preparation of GNR@SiO2 nanoparticles, we found that the silica coating rate of hexadecylcetyltrimethylammonium bromide (CTAB)-capped GNRs is much slower than that of PEGylated GNRs due to the densely coated CTAB bilayer. Encapsulated MB molecules have both monomer and dimer forms that result in an increase in the photosensitizing effect through different photochemical pathways. As a consequence of the excellent plasmonic properties of GNRs at near-infrared (NIR) light, the embedded MB molecules showed NIR light-induced SERS performance with a Raman enhancement factor of 3.0 × 1010, which is enough for the detection of a single cancer cell. Moreover, the MB-GNR@SiO2 nanoparticles exhibit a synergistic effect of photodynamic and photothermal therapies of cancer under single-wavelength NIR laser irradiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R., Naishadham, D., & Jemal, A. (2013) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21166 · Cited by 11,825
LXXIII.—Oxidation of tartaric acid in presence of iron
Fenton, H. J. H. (1894) · J. Chem. Soc., Trans. · doi:10.1039/ct8946500899 · Cited by 3,179
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044 · cited 1×
“Early diagnosis of cancer, in particular, plays a crucial role in increasing the chances of survival, and molecular imaging technology based on nanoscience has emerged as a new paradigm for cancer diagnosis [2].”
Cited by
Nanoparticles in Photodynamic Therapy
Lucky, S. S., Soo, K. C., & Zhang, Y. (2015) · Chemical Reviews · doi:10.1021/cr5004198 · Cited by 2,980
Recent biomedical applications of gold nanoparticles: A review
Elahi, N., Kamali, M., & Baghersad, M. H. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.088 · Cited by 1,174
Gold Nanoparticles in Diagnostics and Therapeutics for Human Cancer
Singh, P., Pandit, S., Mokkapati, V. R. S. S., Garg, A., Ravikumar, V., & Mijakovic, I. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19071979 · Cited by 1,038
“Upon irradiation with NIR (near infra-red) light at 780 nm, the viability of CT-26 cells (Murine colon carcinoma) was found to decrease by 31% for the cells transfected with gold nanorods, while the methylene blue (MB) loaded nanocomposites showed an 11% drop, which indicates a synergistic effect of dual therapy [64].”
BackgroundMethodSERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Li, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Metadata
- Authors
- Seo, S.-H., Kim, B.-M., Joe, A., Han, H.-W., Chen, X., Cheng, Z., & Jang, E.-S.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 35
- Issue
- 10
- Pages
- 3309-3318
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2000201702
- Cited by
- 202
- References
- 3
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.