Cell based metabolic barriers to glucose diffusion: Macrophages and continuous glucose monitoring
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
It is assumed that MQ are central to glucose sensor bio-fouling and therefore have a major negative impact on continuous glucose monitoring (CGM) performance in vivo. However to our knowledge there is no data in the literature to directly support or refute this assumption. Since glucose and oxygen (O2) are key to glucose sensor function in vivo, understanding and controlling glucose and O2 metabolic activity of MQ is likely key to successful glucose sensor performance. We hypothesized that the accumulation of MQ at the glucose sensor-tissue interface will act as “Cell Based Metabolic Barriers” (CBMB) to glucose diffusing from the interstitial tissue compartment to the implanted glucose sensor and as such creating an artificially low sensor output, thereby compromising sensor function and CGM. Our studies demonstrated that 1) direct injections of MQ at in vivo sensor implantation sites dramatically decreased sensor output (measured in nA), 2) addition of MQ to glucose sensors in vitro resulted in a rapid and dramatic fall in sensor output and 3) lymphocytes did not affect sensor function in vitro or in vivo. These data support our hypothesis that MQ can act as metabolic barriers to glucose and O2 diffusion in vivo and in vitro.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“It is universally accepted that macrophages (MQ) are a histologic hallmark of chronic inflammation including foreign body reactions [1].”
Dailey, G. (2011) · Clinical Therapeutics · doi:10.1016/j.clinthera.2011.04.025 · Cited by 66
Metabolic Biofouling of Glucose Sensors in Vivo : Role of Tissue Microhemorrhages
Klueh, U., Liu, Z., Feldman, B., Henning, T. P., Cho, B., Ouyang, T., & Kreutzer, D. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500313 · Cited by 63
Self-citation
Cited by
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235
Advanced strategies to thwart foreign body response to implantable devices
Capuani, S., Malgir, G., Chua, C. Y. X., & Grattoni, A. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10300 · Cited by 195
“mouse macrophages in the proximity of CGM in mouse model, glucose levels measured by the sensor were lower than blood glucose levels.(193)”
MethodDidyuk, O., Econom, N., Guardia, A., Livingston, K., & Klueh, U. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819899394 · Cited by 175
Self-citationProtein Resistant Polymeric Biomaterials
Ngo, B. K. D., & Grunlan, M. A. (2017) · ACS Macro Letters · doi:10.1021/acsmacrolett.7b00448 · Cited by 163
The Role of Macrophages in the Foreign Body Response to Implanted Biomaterials
Yu, T., Tutwiler, V. J., & Spiller, K. (2015) · Biomaterials in Regenerative Medicine and the Immune System · doi:10.1007/978-3-319-18045-8_2 · Cited by 39
Metadata
- Authors
- Klueh, U., Frailey, J. T., Qiao, Y., Antar, O., & Kreutzer, D. L.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 35
- Issue
- 10
- Pages
- 3145-3153
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1981164033
- Cited by
- 42
- References
- 3
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.