The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The interaction of carbon nanotubes with an in vitro blood-brain barrier model and mouse brain in vivo
Open accessAbstract
Carbon nanotubes (CNTs) are a novel nanocarriers with interesting physical and chemical properties. Here we investigate the ability of amino-functionalized multi-walled carbon nanotubes (MWNTs-NH3(+)) to cross the Blood-Brain Barrier (BBB) in vitro using a co-culture BBB model comprising primary porcine brain endothelial cells (PBEC) and primary rat astrocytes, and in vivo following a systemic administration of radiolabelled f-MWNTs. Transmission Electron microscopy (TEM) confirmed that MWNTs-NH3(+) crossed the PBEC monolayer via energy-dependent transcytosis. MWNTs-NH3(+) were observed within endocytic vesicles and multi-vesicular bodies after 4 and 24 h. A complete crossing of the in vitro BBB model was observed after 48 h, which was further confirmed by the presence of MWNTs-NH3(+) within the astrocytes. MWNT-NH3(+) that crossed the PBEC layer was quantitatively assessed using radioactive tracers. A maximum transport of 13.0 ± 1.1% after 72 h was achieved using the co-culture model. f-MWNT exhibited significant brain uptake (1.1 ± 0.3% injected dose/g) at 5 min after intravenous injection in mice, after whole body perfusion with heparinized saline. Capillary depletion confirmed presence of f-MWNT in both brain capillaries and parenchyma fractions. These results could pave the way for use of CNTs as nanocarriers for delivery of drugs and biologics to the brain, after systemic administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrical resistance across the blood-brain barrier in anaesthetized rats: a developmental study.
Butt, A. M., Jones, H. C., & Abbott, N. J. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018243 · Cited by 775
Self-citationDirect imaging of single-walled carbon nanotubes in cells
Porter, A. E., Gass, M., Muller, K., Skepper, J. N., Midgley, P. A., & Welland, M. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.347 · Cited by 564
Zensi, A., Begley, D., Pontikis, C., Legros, C., Mihoreanu, L., Wagner, S., Büchel, C., von Briesen, H., & Kreuter, J. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.03.002 · Cited by 438
Yang, Z., Zhang, Y., Yang, Y., Sun, L., Han, D., Li, H., & Wang, C. (2010) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2009.11.007 · Cited by 311 · cited 1×
“This study provided indirect evidence that SWNTs were able to reach the brain despite the presence of the BBB [25].”
BackgroundCandela, P., Gosselet, F., Miller, F., Buee-Scherrer, V., Torpier, G., Cecchelli, R., & Fenart, L. (2008) · Endothelium · doi:10.1080/10623320802487759 · Cited by 117
Cited by
Smart nanocarrier-based drug delivery systems for cancer therapy and toxicity studies: A review
Hossen, S., Hossain, M. K., Basher, M. K., Mia, M. N. H., Rahman, M. T., & Uddin, M. J. (2019) · Journal of Advanced Research · doi:10.1016/j.jare.2018.06.005 · Cited by 998
“The grafting of the surfaces of GNPs with proper ligands could significantly overcome the blood brain barrier (BBB) [120].”
BackgroundCarbon Nanotubes: Smart Drug/Gene Delivery Carriers
Zare, H., Ahmadi, S., Ghasemi, A., Ghanbari, M., Rabiee, N., Bagherzadeh, M., Karimi, M., Webster, T. J., Hamblin, M. R., & Mostafavi, E. (2021) · International Journal of Nanomedicine · doi:10.2147/ijn.s299448 · Cited by 452
Evolving Drug Delivery Strategies to Overcome the Blood Brain Barrier
S. Hersh, D., S. Wadajkar, A., B. Roberts, N., G. Perez, J., P. Connolly, N., Frenkel, V., A. Winkles, J., F. Woodworth, G., & J. Kim, A. (2016) · Current Pharmaceutical Design · doi:10.2174/1381612822666151221150733 · Cited by 387
“[73] showed that functionalized multi-walled carbon nanotubes (MWNTs) were able to cross an in vitro model of the BBB.”
Applications of nanotechnology in drug delivery to the central nervous system
Saeedi, M., Eslamifar, M., Khezri, K., & Dizaj, S. M. (2019) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.12.133 · Cited by 342
Neurodegenerative and neurological disorders by small inhaled particles
Heusinkveld, H. J., Wahle, T., Campbell, A., Westerink, R. H. S., Tran, L., Johnston, H., Stone, V., Cassee, F. R., & Schins, R. P. F. (2016) · NeuroToxicology · doi:10.1016/j.neuro.2016.07.007 · Cited by 331
Metadata
- Authors
- Kafa, H., Wang, J. T.-W., Rubio, N., Venner, K., Anderson, G., Pach, E., Ballesteros, B., Preston, J. E., Abbott, N. J., & Al-Jamal, K. T.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 53
- Pages
- 437-452
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2088441058
- Cited by
- 214
- References
- 5
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.