Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

A surface-engineered polyetheretherketone biomaterial implant with direct and immunoregulatory antibacterial activity against methicillin-resistant Staphylococcus aureus

Liu, Wei, Li, Jinhua, Cheng, Mengqi, Wang, Qiaojie, Qian, Yebin, Yeung, Kelvin W.K., Chu, Paul K., Zhang, Xianlong·2019·Biomaterials

Abstract

Metal ions or nanoparticles are believed to be promising additives in developing antibacterial biomaterials, owing to possessing favorable bactericidal effects against antibiotic-resistant bacteria. However, the immunomodulatory antibacterial activity of metal ions has seldom been reported. Herein, a porous microstructure designed to trap methicillin-resistant Staphylococcus aureus (MRSA) is fabricated on polyetheretherketone biomaterial surface through sulfonation (SPEEK), following which copper (Cu) nanoparticles, which can kill the trapped MRSA, are immobilized on SPEEK surface using a customized magnetron sputtering technique. In vitro antibacterial and immunological experiments indicate that the Cu-incorporated SPEEK can exert a desirable bactericidal effect against MRSA through the combination of "trap killing" and "contact killing" actions; meanwhile, macrophages cultured on the Cu-incorporated SPEEK can be activated and polarized to a pro-inflammatory phenotype along with improved phagocytic ability on the MRSA. Further in vivo implant-associated infection models evidence the superior antibacterial activity of the Cu-incorporated SPEEK. These results demonstrate multimodal antibacterial actions of the Cu-incorporated SPEEK, which is capable of imposing direct antibacterial and indirect immunomodulatory antibacterial effects simultaneously, in order to prevent and cure MRSA infection. It is believed that this study may shed light on developing novel biomaterial implants that combine antibacterial and immunomodulatory functions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2019.04.008

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 159

Metadata

Authors
Liu, W., Li, J., Cheng, M., Wang, Q., Qian, Y., Yeung, K. W. K., Chu, P. K., & Zhang, X.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2019-07
Volume
208
Pages
8-20
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2938387685
Cited by
159
References
5
FWCI
8.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A surface-engineered polyetheretherketone biomaterial implant with direct and immunoregulatory antibacterial activity against methicillin-resistant Staphylococcus aureus. https://app.cochat.ai/papers/10.1016/j.biomaterials.2019.04.008
The paper
Liu, W., Li, J., Cheng, M., Wang, Q., Qian, Y., Yeung, K. W. K., Chu, P. K., & Zhang, X. (2019). A surface-engineered polyetheretherketone biomaterial implant with direct and immunoregulatory antibacterial activity against methicillin-resistant Staphylococcus aureus. Biomaterials. https://doi.org/10.1016/j.biomaterials.2019.04.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.