A short view on nanohydroxyapatite as coating of dental implants
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
INTRODUCTION Titanium based (Ti-based) materials have been used as dental implants due to their high biocompatibility, good mechanical strength and ideal osseointegration properties. Osseointegration of an implant is dependent on surface characteristics such as surface chemistry and topography. Nanotechnology has presented new and interesting applications in dentistry in recent years. The presence of nanoparticles on the implant surface can affect both the topography and surface chemistry, leading to different and outstanding specifications for implant. METHOD A literature review was performed in electronic databases by means of MeSH keywords to collect relevant published literature in English about the effect of nanohydroxyapatite on osseointegration of titanium implants. No limitations on publication date were imposed. Data regarding titanium implants; nanotechnology; nanohydroxyapatite; osseointegration and cell attachment were collected and reviewed. RESULTS AND CONCLUSION According to reviewed literature, nanohydroxyapatites have a nanostructured surface with higher surface area and then higher reactivity, letting them to bind to bone creating a biomimetic coating on implants. However, more studies are needed on the cell-substrate interface to develop an effective implant due to the interaction of the cells and the biomaterial surface after the implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701
Cited by
Titanium Alloys for Dental Implants: A Review
W. Nicholson, J. (2020) · Prosthesis · doi:10.3390/prosthesis2020011 · Cited by 461
Therapeutic benefits of rutin and its nanoformulations
Negahdari, R., Bohlouli, S., Sharifi, S., Maleki Dizaj, S., Rahbar Saadat, Y., Khezri, K., Jafari, S., Ahmadian, E., Gorbani Jahandizi, N., & Raeesi, S. (2021) · Phytotherapy Research · doi:10.1002/ptr.6904 · Cited by 296
Self-citationBiomimetic hydroxyapatite and caries prevention: a systematic review and meta-analysis.
(2021) · PubMed Central · Cited by 35
Su, T., Zheng, A., Cao, L., Peng, L., Wang, X., Wang, J., Xin, X., & Jiang, X. (2022) · Bio-Design and Manufacturing · doi:10.1007/s42242-022-00184-5 · Cited by 25
The Use of Lactide Polymers in Bone Tissue Regeneration in Dentistry—A Systematic Review
Rajewska, J., Kowalski, J., Matys, J., Dobrzyński, M., & Wiglusz, R. J. (2023) · Journal of Functional Biomaterials · doi:10.3390/jfb14020083 · Cited by 20
Metadata
- Authors
- Yazdani, J., Ahmadian, E., Sharifi, S., Shahi, S., & Maleki Dizaj, S.
- Venue
- Biomedicine & Pharmacotherapy
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 105
- Pages
- 553-557
- ISSN
- 0753-3322 (ISSN-L)
- OpenAlex
- W2806488637
- Cited by
- 114
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A short view on nanohydroxyapatite as coating of dental implants. https://app.cochat.ai/papers/10.1016/j.biopha.2018.06.013
- The paper
- Yazdani, J., Ahmadian, E., Sharifi, S., Shahi, S., & Maleki Dizaj, S. (2018). A short view on nanohydroxyapatite as coating of dental implants. Biomedicine & Pharmacotherapy. https://doi.org/10.1016/j.biopha.2018.06.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.