The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Point-of-care biosensor systems for cancer diagnostics/prognostics
Open accessAbstract
With the growing number of fatalities resulting from the 100 or so cancer-related diseases, new enabling tools are required to provide extensive molecular profiles of patients to guide the clinician in making viable diagnosis and prognosis. Unfortunately with cancer-related diseases, there is not one molecular marker that can provide sufficient information to assist the clinician in making effective prognoses or even diagnoses. Indeed, large panels of markers must typically be evaluated that cut across several different classes (mutations in certain gene fragments--DNA; over/under-expression of gene activity as monitored by messenger RNAs; the amount of proteins present in serum or circulating tumor cells). The classical biosensor format (dipstick approach for monitoring the presence of a single element) is viewed as a valuable tool in many bioassays, but possesses numerous limitations in cancer due primarily to the single element nature of these sensing platforms. As such, if biosensors are to become valuable tools in the arsenal of the clinician to manage cancer patients, new formats are required. This review seeks to provide an overview of the current thinking on molecular profiling for diagnosis and prognosis of cancers and also, provide insight into the current state-of-the-art in the biosensor field and new strategies that must be considered to bring this important technology into the cancer field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087
Chou, S. Y., Krauss, P. R., & Renstrom, P. J. (1996) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.588605 · Cited by 1,729
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Gerion, D., Pinaud, F., Williams, S. C., Parak, W. J., Zanchet, D., Weiss, S., & Alivisatos, A. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp0105488 · Cited by 1,269
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Luminescent CdS Quantum Dots as Selective Ion Probes
Chen, Y., & Rosenzweig, Z. (2002) · Analytical Chemistry · doi:10.1021/ac0258251 · Cited by 915
Self-citationSelf-Assembled Nanoparticle Probes for Recognition and Detection of Biomolecules
Maxwell, D. J., Taylor, J. R., & Nie, S. (2002) · Journal of the American Chemical Society · doi:10.1021/ja025814p · Cited by 890
Bast, R. C., Ravdin, P., Hayes, D. F., Bates, S., Fritsche, H., Jessup, J. M., Kemeny, N., Locker, G. Y., Mennel, R. G., & Somerfield, M. R. (2001) · Journal of Clinical Oncology · doi:10.1200/jco.2001.19.6.1865 · Cited by 879
Self-citationSURVEY AND SUMMARY: From DNA biosensors to gene chips
Wang, J. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.16.3011 · Cited by 753
Self-citation
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Biosensors for cancer markers diagnosis
Tothill, I. E. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.015 · Cited by 552
Metadata
- Authors
- Soper, S. A., Brown, K., Ellington, A., Frazier, B., Garcia-Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B., Landers, J. L., Larson, D., Ligler, F., Majumdar, A., Mascini, M., Nolte, D., Rosenzweig, Z., Wang, J., & Wilson, D.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2006-04
- Volume
- 21
- Issue
- 10
- Pages
- 1932-1942
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2058624276
- Cited by
- 376
- References
- 52
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care biosensor systems for cancer diagnostics/prognostics. https://app.cochat.ai/papers/10.1016/j.bios.2006.01.006
- The paper
- Soper, S. A., Brown, K., Ellington, A., Frazier, B., Garcia-Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B., Landers, J. L., Larson, D., Ligler, F., Majumdar, A., Mascini, M., Nolte, D., Rosenzweig, Z., Wang, J., & Wilson, D. (2006). Point-of-care biosensor systems for cancer diagnostics/prognostics. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2006.01.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.