Characterization of the evanescent field profile and bound mass sensitivity of a label-free silicon photonic microring resonator biosensing platform
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Silicon photonic microring resonators have emerged as a sensitive and highly multiplexed platform for real-time biomolecule detection. Herein, we profile the evanescent decay of device sensitivity towards molecular binding as a function of distance from the microring surface. By growing multilayers of electrostatically bound polymers extending from the sensor surface, we are able to empirically determine that the evanescent field intensity is characterized by a 1/e response decay distance of 63 nm. We then applied this knowledge to study the growth of biomolecular assemblies consisting of alternating layers of biotinylated antibody and streptavidin, which follow a more complex growth pattern. Additionally, by monitoring the shift in microring resonance wavelength upon the deposition of a radioactively labeled protein, the mass sensitivity of the ring resonator platform was determined to be 14.7 ± 6.7 [pg/mm2]/Δpm. By extrapolating to the instrument noise baseline, the absolute mass limit of detection is found to be 1.5 ± 0.7 pg/mm2. Taking the small surface area of the microring sensor into consideration, this value corresponds to an absolute mass detection limit of 97 ag (i.e. 0.6 zmol of IgG), demonstrating the remarkable sensitivity of this promising label-free biomolecular sensing platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iqbal, M., Gleeson, M. A., Spaugh, B., Tybor, F., Gunn, W. G., Hochberg, M., Baehr-Jones, T., Bailey, R. C., & Gunn, L. C. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2032510 · Cited by 551 · cited 2×
“Device: microring resonator sensors and instrumentation The design and fabrication of microring resonator array chips, the accompanying instrumentation, and the fluidics have been described previously (Iqbal et al., 2010; Washburn et al., 2009).”
MethodSelf-citation
Cited by
Bogaerts, W., De Heyn, P., Van Vaerenbergh, T., De Vos, K., Kumar Selvaraja, S., Claes, T., Dumon, P., Bienstman, P., Van Thourhout, D., & Baets, R. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100017 · Cited by 2,643
Whispering gallery mode sensors
Foreman, M. R., Swaim, J. D., & Vollmer, F. (2015) · Advances in Optics and Photonics · doi:10.1364/aop.7.000168 · Cited by 927
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Sypabekova, M., Hagemann, A., Rho, D., & Kim, S. (2022) · Biosensors · doi:10.3390/bios13010036 · Cited by 304
Bioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
“, provide the theoretical framework behind their microring sensors [246].”
Metadata
- Authors
- Luchansky, M. S., Washburn, A. L., Martin, T. A., Iqbal, M., Gunn, L. C., & Bailey, R. C.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 26
- Issue
- 4
- Pages
- 1283-1291
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2035332451
- Cited by
- 109
- References
- 1
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.