Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Smartphone-based integrated voltammetry system for simultaneous detection of ascorbic acid, dopamine, and uric acid with graphene and gold nanoparticles modified screen-printed electrodes

Ji, Daizong, Liu, Zixiang, Liu, Lei, Low, Sze Shin, Lu, Yanli, Yu, Xiongjie, Zhu, Long, Li, Candong, Liu, Qingjun·2018·Biosensors and Bioelectronics

Abstract

Ascorbic acid, dopamine, and uric acid are important electroactive biomolecules for health monitoring and they coexist in serum or urine. Their quantitative determination by electrochemistry could provide the accurate reference for diseases diagnosis and treatment. However, the traditional electrochemical workstations are too large for on-field inspection. Hence, the design of handheld electrochemical system for the detection of biomolecules is significant for point-of-care testing (POCT). In this paper, a smartphone-based integrated voltammetry system using modified electrode was developed for simultaneous detection of biomolecules. The system contained a disposable sensor, a coin-size detector, and a smartphone equipped with application program. Screen-printed electrodes were used as sensors for the detection, on which reduced graphene oxide and gold nanoparticles were electrochemically deposited by the system. The detector was used with voltammetric methods, in which excitation voltage was applied on the sensors and subsequent current responses were detected. The smartphone is the core component to communicate with the detector, calculate data, and plot voltammograms in real-time. Then, the system was applied to detect standard solutions of the biomolecules and their mixtures as examples. The results showed that the peak currents of each substance increased with higher concentration and the method allowed the discrimination of the different potentials of the studied species. Finally, the practical applications of the system were tested through detections of the biomolecules in artificial urine. The results exhibited that the system could be used to detect electrochemical activity of biomolecules with linear, high sensitivity, and specific responses in point-of-care testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2018.07.074

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 192

Metadata

Authors
Ji, D., Liu, Z., Liu, L., Low, S. S., Lu, Y., Yu, X., Zhu, L., Li, C., & Liu, Q.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2018-11
Volume
119
Pages
55-62
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2887684278
Cited by
192
References
1
FWCI
8.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Smartphone-based integrated voltammetry system for simultaneous detection of ascorbic acid, dopamine, and uric acid with graphene and gold nanoparticles modified screen-printed electrodes. https://app.cochat.ai/papers/10.1016/j.bios.2018.07.074
The paper
Ji, D., Liu, Z., Liu, L., Low, S. S., Lu, Y., Yu, X., Zhu, L., Li, C., & Liu, Q. (2018). Smartphone-based integrated voltammetry system for simultaneous detection of ascorbic acid, dopamine, and uric acid with graphene and gold nanoparticles modified screen-printed electrodes. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.07.074

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.