The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Battery‐Free and Wireless Smart Wound Dressing for Wound Infection Monitoring and Electrically Controlled On‐Demand Drug Delivery
Abstract
Real‐time monitoring wound status and providing timely therapies with smart wound dressing is a promising way to treat wound infections and accelerate the healing process. Herein, to establish a closed‐loop monitoring and treatment system, a fully integrated, battery‐free, and wireless smart wound dressing for wound infection detection and on‐demand drug delivery is developed using flexible electronics. The smart wound dressing integrated with the near field communication module can realize wireless power harvest and data transmission, on‐site signal processing, and drug delivery control, through the miniaturized circuit and smartphone. The temperature, pH, and uric acid of the wound is detected simultaneously by the developed sensors to assess wound conditions. Meanwhile, the drug delivery electrode in the dressing is used to provide on‐demand infection treatment by the electrically controlled antibiotics delivery. Through in vitro antibacterial experiments and in situ animal studies, it is shown that the dressing can effectively inhibit bacterial growth and accelerate wound healing, which fully validates its effectiveness in the wound treatment. Utilizing the advantages of near‐field communication and flexible electronics, the battery‐free and integrated design of sensing and treatment provides a promising solution for the development of a closed‐loop biomedical system integrating monitoring, diagnosis, and therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gurtner, G. C., Werner, S., Barrandon, Y., & Longaker, M. T. (2008) · Nature · doi:10.1038/nature07039 · Cited by 6,542
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Wound bed preparation: a systematic approach to wound management
Schultz, G. S., Sibbald, R. G., Falanga, V., Ayello, E. A., Dowsett, C., Harding, K., Romanelli, M., Stacey, M. C., Teot, L., & Vanscheidt, W. (2003) · Wound Repair and Regeneration · doi:10.1046/j.1524-475x.11.s2.1.x · Cited by 1,434
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Influence of pH on wound-healing: a new perspective for wound-therapy?
Schneider, L. A., Korber, A., Grabbe, S., & Dissemond, J. (2007) · Archives of Dermatological Research · doi:10.1007/s00403-006-0713-x · Cited by 1,066
Why chronic wounds will not heal: a novel hypothesis
Bjarnsholt, T., Kirketerp‐Møller, K., Jensen, P. Ø., Madsen, K. G., Phipps, R., Krogfelt, K., Høiby, N., & Givskov, M. (2008) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2007.00283.x · Cited by 886
Drug delivery systems and materials for wound healing applications
Saghazadeh, S., Rinoldi, C., Schot, M., Kashaf, S. S., Sharifi, F., Jalilian, E., Nuutila, K., Giatsidis, G., Mostafalu, P., Derakhshandeh, H., et al. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.04.008 · Cited by 842
Cited by
Wound management materials and technologies from bench to bedside and beyond
Wang, C., Shirzaei Sani, E., Shih, C.-D., Lim, C. T., Wang, J., Armstrong, D. G., & Gao, W. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00693-y · Cited by 396
Recent Advances in Intelligent Wearable Medical Devices Integrating Biosensing and Drug Delivery
Tan, M., Xu, Y., Gao, Z., Yuan, T., Liu, Q., Yang, R., Zhang, B., & Peng, L. (2022) · Advanced Materials · doi:10.1002/adma.202108491 · Cited by 187
Self-citationCheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
A highly stretchable smart dressing for wound infection monitoring and treatment
Su, R., Wang, L., Han, F., Bian, S., Meng, F., Qi, W., Zhai, X., Li, H., Wu, J., Pan, X., et al. (2024) · Materials Today Bio · doi:10.1016/j.mtbio.2024.101107 · Cited by 24
Self-citation
Metadata
- Authors
- Xu, G., Lu, Y., Cheng, C., Li, X., Xu, J., Liu, Z., Liu, J., Liu, G., Shi, Z., Chen, Z., Zhang, F., Jia, Y., Xu, D., Yuan, W., Cui, Z., Low, S. S., & Liu, Q.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-04-18
- Volume
- 31
- Issue
- 26
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3154445566
- Cited by
- 336
- References
- 58
- FWCI
- 19.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Battery‐Free and Wireless Smart Wound Dressing for Wound Infection Monitoring and Electrically Controlled On‐Demand Drug Delivery. https://app.cochat.ai/papers/10.1002/adfm.202100852
- The paper
- Xu, G., Lu, Y., Cheng, C., Li, X., Xu, J., Liu, Z., Liu, J., Liu, G., Shi, Z., Chen, Z., Zhang, F., Jia, Y., Xu, D., Yuan, W., Cui, Z., Low, S. S., & Liu, Q. (2021). Battery‐Free and Wireless Smart Wound Dressing for Wound Infection Monitoring and Electrically Controlled On‐Demand Drug Delivery. Advanced Functional Materials. https://doi.org/10.1002/adfm.202100852
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.