The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Direct quantification of cancerous exosomes via surface plasmon resonance with dual gold nanoparticle-assisted signal amplification
Open accessAbstract
Sensitive detection of cancerous exosomes is critical to early diseases diagnosis and prognosis. Herein, a sensitive aptasensor was demonstrated for exosomes detection by surface plasmon resonance (SPR) with dual gold nanoparticle (AuNP)-assisted signal amplification. Dual nanoparticle amplification was achieved by controlled hybridization attachment of AuNPs resulting from electronic coupling between the Au film and AuNPs, as well as coupling effects in plasmonic nanostructures. By blocking the Au film surface with 11-Mercapto-1 -undecanol (MCU), nonspecific adsorption of AuNPs onto the SPR chip surface was suppressed and regeneration of the SPR sensor was realized. This method was highly sensitive and we have achieved the limit of detection (LOD) down to 5 × 103 exosomes/mL, which showed a 104-fold improvement in LOD compared to commercial ELISA. Moreover, the SPR sensor had the capability to differentiate the exosomes secreted by MCF-7 breast cancer cells and MCF-10A normal breast cells. Furthermore, the SPR sensor could effectively detect the exosomes in 30% fetal bovine serum. The work provides a sensitive and efficient quantification approach to detect cancerous exosomes and offers an avenue toward future diagnosis and comprehensive studies of exosomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extracellular vesicles: Exosomes, microvesicles, and friends
Raposo, G., & Stoorvogel, W. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201211138 · Cited by 8,099
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885
Fang, T., Lv, H., Lv, G., Li, T., Wang, C., Han, Q., Yu, L., Su, B., Guo, L., Huang, S., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02583-0 · Cited by 995
Cited by
Exosomes as a new frontier of cancer liquid biopsy
Yu, D., Li, Y., Wang, M., Gu, J., Xu, W., Cai, H., Fang, X., & Zhang, X. (2022) · Molecular Cancer · doi:10.1186/s12943-022-01509-9 · Cited by 855
Research advances on surface plasmon resonance biosensors
Wang, Q., Ren, Z.-H., Zhao, W.-M., Wang, L., Yan, X., Zhu, A.-S., Qiu, F.-M., & Zhang, K.-K. (2022) · Nanoscale · doi:10.1039/d1nr05400g · Cited by 267
Self-citationMicrofluidic Technology for the Isolation and Analysis of Exosomes
Wu, Y., Wang, Y., Lu, Y., Luo, X., Huang, Y., Xie, T., Pilarsky, C., Dang, Y., & Zhang, J. (2022) · Micromachines · doi:10.3390/mi13101571 · Cited by 91
Analysis of extracellular vesicles as emerging theranostic nanoplatforms
Xing, Y., Cheng, Z., Wang, R., Lv, C., James, T. D., & Yu, F. (2020) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2020.213506 · Cited by 67
Tian, T., Qiao, S., & Tannous, B. A. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c07981 · Cited by 27
Metadata
- Authors
- Wang, Q., Zou, L., Yang, X., Liu, X., Nie, W., Zheng, Y., Cheng, Q., & Wang, K.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 135
- Pages
- 129-136
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2936692457
- Cited by
- 230
- References
- 3
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct quantification of cancerous exosomes via surface plasmon resonance with dual gold nanoparticle-assisted signal amplification. https://app.cochat.ai/papers/10.1016/j.bios.2019.04.013
- The paper
- Wang, Q., Zou, L., Yang, X., Liu, X., Nie, W., Zheng, Y., Cheng, Q., & Wang, K. (2019). Direct quantification of cancerous exosomes via surface plasmon resonance with dual gold nanoparticle-assisted signal amplification. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.04.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.