Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

A 2D transition metal carbide MXene-based SPR biosensor for ultrasensitive carcinoembryonic antigen detection

Wu, Qiong, Li, Ningbo, Wang, Ying, liu, Ying, Xu, Yanchao, Wei, Shuting, Wu, Jiandong, Jia, Guangri, Fang, Xuedong, Chen, Fangfang, Cui, Xiaoqiang·2019·Biosensors and Bioelectronics

Abstract

Surface plasmon resonance (SPR) has become a leading technique for in situ bioaffinity assay of diverse targets without need of fluorescent or enzymatic labeling. Nanomaterials-enhanced SPR sensors have developed rapidly and widened the application scope of SPR sensing technology. In this report we describe an ultrasensitive SPR biosensor for detecting carcinoembryonic antigen (CEA). Our SPR biosensor utilizes a Ti3C2-MXene-based sensing platform and multi-walled carbon nanotube (MWCNTs)-polydopamine (PDA)-Ag nanoparticle (AgNPs) signal enhancer. Ti3C2-MXene, a new class of two-dimensional (2D) transition metal carbides, offers a large hydrophilic-biocompatible surface ideal for SPR biosensing. Ti3C2-MXene/AuNPs composites after synthesis are then decorated with staphylococcal protein A (SPA) to orient and immobilize monoclonal anti-CEA antibody (Ab1) through its Fc region. By introducing MWCNTs-PDA-AgNPs-polyclonal anti-CEA antibody (MWPAg-Ab2) conjugate combined with a sandwich format, the present method provides a dynamic range for CEA determination of 2×10-16 to 2×10-8 M and a detection limit of 0.07 fM. This biosensing approach demonstrates good reproducibility and high specificity for CEA in real serum samples providing a promising method to evaluate CEA in human serum for early diagnosis and monitoring of cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.111697

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Cited by

See all 256

Metadata

Authors
Wu, Q., Li, N., Wang, Y., liu, Y., Xu, Y., Wei, S., Wu, J., Jia, G., Fang, X., Chen, F., & Cui, X.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-11
Volume
144
Pages
111697
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2973181640
Cited by
256
References
37
FWCI
7.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 2D transition metal carbide MXene-based SPR biosensor for ultrasensitive carcinoembryonic antigen detection. https://app.cochat.ai/papers/10.1016/j.bios.2019.111697
The paper
Wu, Q., Li, N., Wang, Y., liu, Y., Xu, Y., Wei, S., Wu, J., Jia, G., Fang, X., Chen, F., & Cui, X. (2019). A 2D transition metal carbide MXene-based SPR biosensor for ultrasensitive carcinoembryonic antigen detection. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.111697

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.