The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
A 2D transition metal carbide MXene-based SPR biosensor for ultrasensitive carcinoembryonic antigen detection
Abstract
Surface plasmon resonance (SPR) has become a leading technique for in situ bioaffinity assay of diverse targets without need of fluorescent or enzymatic labeling. Nanomaterials-enhanced SPR sensors have developed rapidly and widened the application scope of SPR sensing technology. In this report we describe an ultrasensitive SPR biosensor for detecting carcinoembryonic antigen (CEA). Our SPR biosensor utilizes a Ti3C2-MXene-based sensing platform and multi-walled carbon nanotube (MWCNTs)-polydopamine (PDA)-Ag nanoparticle (AgNPs) signal enhancer. Ti3C2-MXene, a new class of two-dimensional (2D) transition metal carbides, offers a large hydrophilic-biocompatible surface ideal for SPR biosensing. Ti3C2-MXene/AuNPs composites after synthesis are then decorated with staphylococcal protein A (SPA) to orient and immobilize monoclonal anti-CEA antibody (Ab1) through its Fc region. By introducing MWCNTs-PDA-AgNPs-polyclonal anti-CEA antibody (MWPAg-Ab2) conjugate combined with a sandwich format, the present method provides a dynamic range for CEA determination of 2×10-16 to 2×10-8 M and a detection limit of 0.07 fM. This biosensing approach demonstrates good reproducibility and high specificity for CEA in real serum samples providing a promising method to evaluate CEA in human serum for early diagnosis and monitoring of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two‐Dimensional Nanocrystals Produced by Exfoliation of Ti3AlC2
Naguib, M., Kurtoglu, M., Presser, V., Lu, J., Niu, J., Heon, M., Hultman, L., Gogotsi, Y., & Barsoum, M. W. (2011) · Advanced Materials · doi:10.1002/adma.201102306 · Cited by 11,855
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Guidelines for Synthesis and Processing of Two-Dimensional Titanium Carbide (Ti3C2Tx MXene)
Alhabeb, M., Maleski, K., Anasori, B., Lelyukh, P., Clark, L., Sin, S., & Gogotsi, Y. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b02847 · Cited by 5,045
Two-Dimensional Ultrathin MXene Ceramic Nanosheets for Photothermal Conversion
Lin, H., Wang, X., Yu, L., Chen, Y., & Shi, J. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04339 · Cited by 1,314
Nanomaterials enhanced surface plasmon resonance for biological and chemical sensing applications
Zeng, S., Baillargeat, D., Ho, H.-P., & Yong, K.-T. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60479a · Cited by 1,230
Peng, J., Chen, X., Ong, W.-J., Zhao, X., & Li, N. (2019) · Chem · doi:10.1016/j.chempr.2018.08.037 · Cited by 829
Self-citationXuan, J., Wang, Z., Chen, Y., Liang, D., Cheng, L., Yang, X., Liu, Z., Ma, R., Sasaki, T., & Geng, F. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201606643 · Cited by 595
Liu, H., Duan, C., Yang, C., Shen, W., Wang, F., & Zhu, Z. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.090 · Cited by 475
Jun, B.-M., Kim, S., Heo, J., Park, C. M., Her, N., Jang, M., Huang, Y., Han, J., & Yoon, Y. (2019) · Nano Research · doi:10.1007/s12274-018-2225-3 · Cited by 457
VahidMohammadi, A., Mojtabavi, M., Caffrey, N. M., Wanunu, M., & Beidaghi, M. (2019) · Advanced Materials · doi:10.1002/adma.201806931 · Cited by 401
Zhang, H., Wang, Z., Zhang, Q., Wang, F., & Liu, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.016 · Cited by 331
Self-citationFlexible and Freestanding Silicon/MXene Composite Papers for High-Performance Lithium-Ion Batteries
Tian, Y., An, Y., & Feng, J. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b21893 · Cited by 330
Zhang, Q., Wang, F., Zhang, H., Zhang, Y., Liu, M., & Liu, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03083 · Cited by 310
Self-citationXiao, Z., Li, Z., Li, P., Meng, X., & Wang, R. (2019) · ACS Nano · doi:10.1021/acsnano.9b00177 · Cited by 300
Lorencova, L., Bertok, T., Filip, J., Jerigova, M., Velic, D., Kasak, P., Mahmoud, K. A., & Tkac, J. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.02.124 · Cited by 282
Determination of peak positions and areas from wide‐scan XPS spectra
Turner, N. H., & Single, A. M. (1990) · Surface and Interface Analysis · doi:10.1002/sia.740150305 · Cited by 270
Graphene-based electrochemical biosensors for monitoring noncommunicable disease biomarkers
Taniselass, S., Arshad, M. K. M., & Gopinath, S. C. B. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.047 · Cited by 238
Han, Q., Wang, R., Xing, B., Zhang, T., Khan, M. S., Wu, D., & Wei, Q. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.034 · Cited by 234
He, P., Wang, X.-X., Cai, Y.-Z., Shu, J.-C., Zhao, Q.-L., Yuan, J., & Cao, M.-S. (2019) · Nanoscale · doi:10.1039/c8nr10489a · Cited by 206
Guo, C., Su, F., Song, Y., Hu, B., Wang, M., He, L., Peng, D., & Zhang, Z. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b14952 · Cited by 203
Vashist, S. K., Dixit, C. K., MacCraith, B. D., & O'Kennedy, R. (2011) · The Analyst · doi:10.1039/c1an15325k · Cited by 179
Majd, S. M., Salimi, A., & Ghasemi, F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.009 · Cited by 164
Graphene Oxide as an Optical Biosensing Platform: A Progress Report
Morales‐Narváez, E., & Merkoçi, A. (2018) · Advanced Materials · doi:10.1002/adma.201805043 · Cited by 160
Sulfur-Doped Graphene-Based Immunological Biosensing Platform for Multianalysis of Cancer Biomarkers
Ren, X., Ma, H., Zhang, T., Zhang, Y., Yan, T., Du, B., & Wei, Q. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b13416 · Cited by 159
Electrochemical paper based cancer biosensor using iron oxide nanoparticles decorated PEDOT:PSS
Kumar, S., Umar, M., Saifi, A., Kumar, S., Augustine, S., Srivastava, S. K., & Malhotra, B. D. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.053 · Cited by 156
Tie, L., Yang, S., Yu, C., Chen, H., Liu, Y., Dong, S., Sun, J., & Sun, J. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.03.014 · Cited by 155
Self-citationWei, T., Zhang, X., Zhang, Q., Yang, J., Chen, Q., Wang, J., Li, X., Chen, J., Ma, T., Li, G., et al. (2019) · Cancer Letters · doi:10.1016/j.canlet.2019.03.009 · Cited by 144
Self-citationDjire, A., Zhang, H., Liu, J., Miller, E. M., & Neale, N. R. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b01150 · Cited by 134
Bai, X., Wang, L.-H., Ren, J., Bai, X.-W., Zeng, L., Shen, A., & Hu, J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05153 · Cited by 106
The Electronic Structure of Some Palladium Alloys Studied by ESCA and X-ray Spectroscopy
Hedman, J., Klasson, M., Nilsson, R., et al. (1971) · Physica Scripta · doi:10.1088/0031-8949/4/4-5/008 · Cited by 93
Oyedotun, K. O., Momodu, D. Y., Naguib, M., Mirghni, A. A., Masikhwa, T. M., Khaleed, A. A., Kebede, M. A., & Manyala, N. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.01.158 · Cited by 84
Wang, Y., Wei, Z., Luo, X., Wan, Q., Qiu, R., & Wang, S. (2018) · Talanta · doi:10.1016/j.talanta.2018.11.011 · Cited by 71
Self-citationLin, Y., Li, L., Hu, L., Liu, K., & Xu, Y. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.113 · Cited by 54
Self-citationLv, H., Li, Y., Zhang, X., Gao, Z., Feng, J., Wang, P., & Dong, Y. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.12.030 · Cited by 54
Parate, K., Karunakaran, C., & Claussen, J. C. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.02.032 · Cited by 50
Wu, J., Lu, Y., Wu, Z., Li, S., Zhang, Q. Y., Chen, Z., Jiang, J., Lin, S., Zhu, L., Li, C., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.166 · Cited by 47
Self-citationTran, D. T., Hoa, V. H., Le, H. T., Kim, N. H., & Lee, J. H. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.022 · Cited by 47
Cited by
Ti3C2TX MXene for Sensing Applications: Recent Progress, Design Principles, and Future Perspectives
Pei, Y., Zhang, X., Hui, Z., Zhou, J., Huang, X., Sun, G., & Huang, W. (2021) · ACS Nano · doi:10.1021/acsnano.1c00248 · Cited by 799
Sensing with MXenes: Progress and Prospects
Ho, D. H., Choi, Y. Y., Jo, S. B., Myoung, J., & Cho, J. H. (2021) · Advanced Materials · doi:10.1002/adma.202005846 · Cited by 482
MXene in the lens of biomedical engineering: synthesis, applications and future outlook
Zamhuri, A., Lim, G. P., Ma, N. L., Tee, K. S., & Soon, C. F. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-021-00873-9 · Cited by 277
2D metal carbides and nitrides (MXenes) for sensors and biosensors
Alwarappan, S., Nesakumar, N., Sun, D., Hu, T. Y., & Li, C.-Z. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113943 · Cited by 262
Li, R., Fan, H., Zhou, H., Chen, Y., Yu, Q., Hu, W., Liu, G. L., & Huang, L. (2023) · Advanced Science · doi:10.1002/advs.202301658 · Cited by 60
Metadata
- Authors
- Wu, Q., Li, N., Wang, Y., liu, Y., Xu, Y., Wei, S., Wu, J., Jia, G., Fang, X., Chen, F., & Cui, X.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 144
- Pages
- 111697
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2973181640
- Cited by
- 256
- References
- 37
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.