The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Single-layered ultra-soft washable smart textiles for all-around ballistocardiograph, respiration, and posture monitoring during sleep
Abstract
Good sleep is considered to be the cornerstone for maintaining both physical and mental health. However, nearly one billion people worldwide suffer from various sleep disorders. To date, polysomnography (PSG) is the most commonly used sleep-monitoring technology,however, it is complex, intrusive, expensive and uncomfortable. Unfortunately, present noninvasive monitoring technologies cannot simultaneously achieve high sensitivity, multi-parameter monitoring and comfort. Here, we present a single-layered, ultra-soft, smart textile for all-around physiological parameters monitoring and healthcare during sleep. With a high-pressure sensitivity of 10.79 mV/Pa, a wide working frequency bandwidth from 0 Hz to 40 Hz, good stability, and decent washability, the single-layered ultra-soft smart textile is simultaneously capable of real-time detection and tracking of dynamic changes in sleep posture, and subtle respiration and ballistocardiograph (BCG) monitoring. Using the set of patient generated health data, an obstructive sleep apnea-hypopnea syndrome (OSAHS) monitoring and intervention system was also developed to improve the sleep quality and prevent sudden death during sleep. This work is expected to pave a new and practical pathway for physiological monitoring during sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Obstructive Sleep Apnea as a Risk Factor for Stroke and Death
Yaggi, H. K., Concato, J., Kernan, W. N., Lichtman, J. H., Brass, L. M., & Mohsenin, V. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043104 · Cited by 3,004 · cited 1×
“However, nearly one billion people worldwide suffer from a variety of sleep disorders, including obstructive sleep apnea-hypopnea syndrome (OSAHS), insomnia and circadian rhythm disorder (King and Cuellar, 2016; Koehler et al., 2014; Somers et al., 1995; Yaggi et al., 2005).”
BackgroundSympathetic neural mechanisms in obstructive sleep apnea.
Somers, V. K., Dyken, M. E., Clary, M. P., & Abboud, F. M. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118235 · Cited by 2,527
Micro-cable structured textile for simultaneously harvesting solar and mechanical energy
Chen, J., Huang, Y., Zhang, N., Zou, H., Liu, R., Tao, C., Fan, X., & Wang, Z. L. (2016) · Nature Energy · doi:10.1038/nenergy.2016.138 · Cited by 1,060
Self-citationReviving Vibration Energy Harvesting and Self-Powered Sensing by a Triboelectric Nanogenerator
Chen, J., & Wang, Z. L. (2017) · Joule · doi:10.1016/j.joule.2017.09.004 · Cited by 1,021
Self-citationChen, J., Zhu, G., Yang, W., Jing, Q., Bai, P., Yang, Y., Hou, T., & Wang, Z. L. (2013) · Advanced Materials · doi:10.1002/adma.201302397 · Cited by 822
Self-citationA Wireless Textile-Based Sensor System for Self-Powered Personalized Health Care
Meng, K., Zhao, S., Zhou, Y., Wu, Y., Zhang, S., He, Q., Wang, X., Zhou, Z., Fan, W., Tan, X., et al. (2020) · Matter · doi:10.1016/j.matt.2019.12.025 · Cited by 450
Self-citationKendzerska, T., Gershon, A. S., Hawker, G., Leung, R. S., & Tomlinson, G. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001599 · Cited by 428
The Indications for Polysomnography and Related Procedures
Chesson, A. L., Ferber, R. A., Fry, J. M., Grigg-Damberger, M., Hartse, K. M., Hurwitz, T. D., Johnson, S., Kader, G. A., Littner, M., Rosen, G., et al. (1997) · Sleep · doi:10.1093/sleep/20.6.423 · Cited by 362
Watanabe, K., Watanabe, T., Watanabe, H., Ando, H., Ishikawa, T., & Kobayashi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.857637 · Cited by 239
The relationship between systemic hypertension and obstructive sleep apnea: Facts and theory
Fletcher, E. C. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80395-7 · Cited by 236
Yan, C., Gao, Y., Zhao, S., Zhang, S., Zhou, Y., Deng, W., Li, Z., Jiang, G., Jin, L., Tian, G., et al. (2020) · Nano Energy · doi:10.1016/j.nanoen.2019.104235 · Cited by 209
Self-citationManocchia, M., Keller, S., & Ware, J. E. (2001) · Quality of Life Research · doi:10.1023/a:1012299519637 · Cited by 196
Chen, S., Wu, N., Ma, L., Lin, S., Yuan, F., Xu, Z., Li, W., Wang, B., & Zhou, J. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b17723 · Cited by 170
Zhou, Z., Li, X., Wu, Y., Zhang, H., Lin, Z., Meng, K., Lin, Z., He, Q., Sun, C., Yang, J., et al. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.08.055 · Cited by 158
Self-citationEpidermis-Inspired Ultrathin 3D Cellular Sensor Array for Self-Powered Biomedical Monitoring
Yan, C., Deng, W., Jin, L., Yang, T., Wang, Z., Chu, X., Su, H. F., Chen, J., & Yang, W. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b14514 · Cited by 156
Self-citationSleep devices: wearables and nearables, informational and interventional, consumer and clinical
Bianchi, M. T. (2017) · Metabolism · doi:10.1016/j.metabol.2017.10.008 · Cited by 140
Smart textile using hetero-core optical fiber for heartbeat and respiration monitoring
Koyama, Y., Nishiyama, M., & Watanabe, K. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2847333 · Cited by 126
Tran, V. P., Al-Jumaily, A. A., & Islam, S. M. S. (2019) · Big Data and Cognitive Computing · doi:10.3390/bdcc3010003 · Cited by 107
Zero-Effort In-Home Sleep and Insomnia Monitoring using Radio Signals
Hsu, C.-Y., Ahuja, A., Yue, S., Hristov, R., Kabelac, Z., & Katabi, D. (2017) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3130924 · Cited by 97
Jouët, P., Sabaté, J., Maillard, D., Msika, S., Mechler, C., Ledoux, S., Harnois, F., & Coffin, B. (2007) · Obesity Surgery · doi:10.1007/s11695-007-9085-3 · Cited by 96
Relationships Between Questionnaire Ratings of Sleep Quality and Polysomnography in Healthy Adults
Westerlund, A., Lagerros, Y. T., Kecklund, G., Axelsson, J., & Åkerstedt, T. (2014) · Behavioral Sleep Medicine · doi:10.1080/15402002.2014.974181 · Cited by 96
Van Houdenhove, L., Buyse, B., Gabriëls, L., & Van den Bergh, O. (2011) · Journal of Clinical Psychology in Medical Settings · doi:10.1007/s10880-011-9250-7 · Cited by 76
Stand-Alone Heartbeat Detection in Multidimensional Mechanocardiograms
Kaisti, M., Tadi, M. J., Lahdenoja, O., Hurnanen, T., Saraste, A., Pänkäälä, M., & Koivisto, T. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2874706 · Cited by 69
Portable Monitoring for the Diagnosis of OSA
Cooksey, J. A., & Balachandran, J. S. (2015) · CHEST Journal · doi:10.1378/chest.15-1076 · Cited by 66
Lee, H. J., Hwang, S. H., Yoon, H. N., Lee, W., & Park, K. S. (2015) · Sensors · doi:10.3390/s150511295 · Cited by 64
King, S., & Cuellar, N. G. (2016) · Journal of Neuroscience Nursing · doi:10.1097/jnn.0000000000000196 · Cited by 43
Sadek, I., Biswas, J., Abdulrazak, B., Haihong, Z., & Mokhtari, M. (2017) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2017.7897262 · Cited by 40
Zhao, Y. Y., Blackwell, T., Ensrud, K. E., Stone, K. L., Omachi, T. A., Redline, S. S., & for the Osteoporotic Fractures in Men (MrOS) Study Group (2016) · SLEEP · doi:10.5665/sleep.5960 · Cited by 38
Validation of the Sleep-Wake Scoring of a New Wrist-Worn Sleep Monitoring Device
Pigeon, W. R., Taylor, M. L., Bui, A., Oleynk, C., Walsh, P., & Bishop, T. M. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7180 · Cited by 34
Tuohy, C. V., Montez‐Rath, M. E., Turakhia, M. P., Chang, T. I., Winkelman, J. W., & Winkelmayer, W. C. (2016) · BMC Nephrology · doi:10.1186/s12882-016-0229-3 · Cited by 30
Obstructive sleep apnoea, resistant hypertension and renal denervation
Witkowski, A., & Kądziela, J. (2013) · EuroIntervention · doi:10.4244/eijv9sra18 · Cited by 16
Obstruktive Schlafapnoe bei neurologischen Erkrankungen
Koehler, U., Cassel, W., Hildebrandt, O., Kesper, K., Kianinejad, P., Nell, C., Mayer, G., & Ohl, G. (2013) · Der Nervenarzt · doi:10.1007/s00115-013-3890-9 · Cited by 15
Prevalence of Sleep Disordered Breathing among Patients with Nocturia at a Urology Clinic
Yamamoto, U., Nishizaka, M., Yoshimura, C., Kawagoe, N., Hayashi, A., Kadokami, T., & Ando, S. (2016) · Internal Medicine · doi:10.2169/internalmedicine.55.5769 · Cited by 15
Cited by
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Self-citationSign-to-speech translation using machine-learning-assisted stretchable sensor arrays
Zhou, Z., Chen, K., Li, X., Zhang, S., Wu, Y., Zhou, Y., Meng, K., Sun, C., He, Q., Fan, W., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-0428-6 · Cited by 841
Self-citationSmart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Self-citationElectronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Self-citationSelf‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Self-citation
Metadata
- Authors
- Zhou, Z., Padgett, S., Cai, Z., Conta, G., Wu, Y., He, Q., Zhang, S., Sun, C., Liu, J., Fan, E., Meng, K., Lin, Z., Uy, C., Yang, J., & Chen, J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 155
- Pages
- 112064
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3010157237
- Cited by
- 313
- References
- 35
- FWCI
- 16.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.