Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Noncontact Heartbeat and Respiration Monitoring Based on a Hollow Microstructured Self-Powered Pressure Sensor

Chen, Shuwen, Wu, Nan, Ma, Long, Lin, Shizhe, Yuan, Fang, Xu, Zisheng, Li, Wenbo, Wang, Bo, Zhou, Jun·2018·ACS Applied Materials & Interfaces

Abstract

Advances in mobile networks and low-power electronics have driven smart mobile medical devices at a tremendous pace, evoking increased interest in household healthcare, especially for those with cardiovascular or respiratory disease. Thus, flexible battery-free pressure sensors, with great potential for monitoring respiration and heartbeat in a smart way, are urgently demanded. However, traditional flexible battery-free pressure sensors for subtle physiological signal detecting are mostly tightly adhered onto the skin instead of working under the pressure of body weight in a noncontact mode, as the low sensitivity in the high-pressure region can hardly meet the demands. Moreover, a hollow microstructure (HM) with higher deformation than solid microstructures and great potential for improving the pressure sensitivity of self-powered sensors has never been investigated. Here, for the first time, we demonstrated a noncontact heartbeat and respiration monitoring system based on a flexible HM-enhanced self-powered pressure sensor, which possesses the advantages of low cost, a high dynamic-pressure sensitivity of 18.98 V·kPa –1, and a wide working range of 40 kPa simultaneously. Specific superiority of physiological detection under a high pressure is also observed. Continuous reliable heartbeat and respiration information is successfully detected in a noncontact mode and transmitted to a mobile phone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.7b17723

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 170

Metadata

Authors
Chen, S., Wu, N., Ma, L., Lin, S., Yuan, F., Xu, Z., Li, W., Wang, B., & Zhou, J.
Venue
ACS Applied Materials & Interfaces
Published
2018-01-17
Volume
10
Issue
4
Pages
3660-3667
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2782155276
Cited by
170
References
13
FWCI
6.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noncontact Heartbeat and Respiration Monitoring Based on a Hollow Microstructured Self-Powered Pressure Sensor. https://app.cochat.ai/papers/10.1021/acsami.7b17723
The paper
Chen, S., Wu, N., Ma, L., Lin, S., Yuan, F., Xu, Z., Li, W., Wang, B., & Zhou, J. (2018). Noncontact Heartbeat and Respiration Monitoring Based on a Hollow Microstructured Self-Powered Pressure Sensor. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b17723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.