Cited by 127Non-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting MaterialsAdvanced Fiber Optic Sensors

Smart textile using hetero-core optical fiber for heartbeat and respiration monitoring

Open access
Koyama, Yuya, Nishiyama, Michiko, Watanabe, Kazuhiro·2018·IEEE Sensors Journal

Abstract

This paper aims to describe a novel smart textile that uses a single-mode hetero-core optical fiber sensor for monitoring heartbeat and respiration. The smart textile was designed by weaving hetero-core optical fibers together with the wool fabric. This novel textile that can detect variations in shapes can be incorporated into clothes. Such clothes can offer comfort to the wearer. To simultaneously monitor heartbeat and respiration, the proposed textile is sewn on to the clothes to be able to sense minute load changes produced by chest movements. The vital signs, which were calculated from the heartbeat and respiration frequency of a healthy adult, while sitting, were in agreement with those verified using commercial monitoring devices. In addition, to confirm the capability of monitoring vital signs, seven monitoring trials were performed in which the subjects were asked to wear and take off the smart cloth. The vital signs rates were successfully extracted within the four beats per minute error by the fiber optic sensor system. The proposed smart textile in clothes can monitor vital signs in daily life activities, such as sitting and standing.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jsen.2018.2847333

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hetero-core optical fiber woven together with wool fibers offers a simple and cost-effective system for monitoring HR and RR.

    “Hetero-core optical fiber woven together with wool fibers [208] offers a simple and cost-effective system for monitoring HR and RR.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [208]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Koyama, Y., Nishiyama, M., & Watanabe, K.
Affiliations
Soka University (JP)
Venue
IEEE Sensors Journal
Published
2018-08-01
Volume
18
Issue
15
Pages
6175-6180
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2808223900
Cited by
126
References
21
Citations by year
2026: 9 · 2025: 14 · 2024: 20 · 2023: 19 · 2022: 29 · 2021: 12 · 2020: 12 · 2019: 8 · 2018: 3
FWCI
3.50
Type
journal article
Language
en
Open access
Locations
IEEE Sensors Journal (publishedVersion)
Funders
Japan Society for the Promotion of Science (JP 17K18185)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
Keywords
hetero-core optical fiber, fiber optic sensors, heart rate monitoring, respiratory monitoring, vital signs monitoring, wearable sensing, wool fabrics, single-mode fiber

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review