Rapid and unamplified identification of COVID-19 with morpholino-modified graphene field-effect transistor nanosensor
Open accessAbstract
SARS-CoV-2 RNA is identified as a pivotal player to bolster energizing zones of COVID-19 detection. Herein, we develop a rapid and unamplified nanosensing platform for detection of SARS-CoV-2 RNA in human throat swab specimens. A gold nanoparticle (AuNP)-decorated graphene field-effect transistor (G-FET) sensor was fabricated, after which complementary phosphorodiamidate morpholino oligos (PMO) probe was immobilized on the AuNP surface. This sensor allowed for highly sensitive testing of SARS-CoV-2 RdRp as PMO does not have charges, leading to low background signal. Not only did the method present a low limit of detection in PBS (0.37 fM), throat swab (2.29 fM), and serum (3.99 fM), but also it achieved a rapid response to COVID-19 patients’ samples within 2 min. The developed nanosensor was capable of analyzing RNA extracts from 30 real clinical samples. The results show that the sensor could differentiate the healthy people from infected people, which are in high agreement with RT-PCR results (Kappa index = 0.92). Furthermore, a well-defined distinction between SARS-CoV-2 RdRp and SARS-CoV RdRp was also made. Therefore, we believe that this work provides a satisfactory, attractive option for COVID-19 diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryo-EM structure of the 2019-nCoV spike in the prefusion conformation
Wrapp, D., Wang, N., Corbett, K. S., Goldsmith, J. A., Hsieh, C.-L., Abiona, O., Graham, B. S., & McLellan, J. S. (2020) · Science · doi:10.1126/science.abb2507 · Cited by 8,897
Viral load of SARS-CoV-2 in clinical samples.
Pan, Y., Zhang, D., Yang, P., Poon, L. L. M., & Wang, Q. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30113-4 · Cited by 1,562 · cited 1×
“According to literature reports, of note, the overall viral load of respiratory samples collected from 82 infected patients was higher than 1 × 103 copies/μL shortly after symptom onset (Pan et al., 2020), which considerably exceeds the above-mentioned detection limit (223 copies/μL).”
BackgroundPreexisting and de novo humoral immunity to SARS-CoV-2 in humans
Ng, K. W., Faulkner, N., Cornish, G. H., Rosa, A., Harvey, R., Hussain, S., Ulferts, R., Earl, C., Wrobel, A. G., Benton, D. J., et al. (2020) · Science · doi:10.1126/science.abe1107 · Cited by 886
Cited by
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Li, J., Ni, W., Jin, D., Yu, Y., Xiao, M.-M., Zhang, Z.-Y., & Zhang, G.-J. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c05751 · Cited by 60
Self-citation
Metadata
- Authors
- Li, J., Wu, D., Yu, Y., Li, T., Li, K., Xiao, M.-M., Li, Y., Zhang, Z.-Y., & Zhang, G.-J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-07
- Volume
- 183
- Pages
- 113206
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3141530029
- Cited by
- 191
- References
- 3
- FWCI
- 12.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid and unamplified identification of COVID-19 with morpholino-modified graphene field-effect transistor nanosensor. https://app.cochat.ai/papers/10.1016/j.bios.2021.113206
- The paper
- Li, J., Wu, D., Yu, Y., Li, T., Li, K., Xiao, M.-M., Li, Y., Zhang, Z.-Y., & Zhang, G.-J. (2021). Rapid and unamplified identification of COVID-19 with morpholino-modified graphene field-effect transistor nanosensor. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.