Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

The terahertz electromagnetically induced transparency-like metamaterials for sensitive biosensors in the detection of cancer cells

Yan, Xin, Yang, Maosheng, Zhang, Zhang, Liang, Lanju, Wei, Dequan, Wang, Meng, Zhang, Mengjin, Wang, Tao, Liu, Longhai, Xie, Jianhua, Yao, Jianquan·2019·Biosensors and Bioelectronics

Abstract

A kind of novel biosensor based on the electromagnetic induced transparency like (EIT-like) metamaterials (MMs) have been proposed. It demonstrates that the symmetry-breaking double-splits ring resonators can realize the EIT-like plasmonic resonance, the according transparency window occurs at 1.67 THz. The coupled oscillators model illustrates that with the increase of asymmetry degree of double splits, the coupling between bright and dark mode is enhanced. Consequently, the non-radiative damping γ2 grows from 1.45 to 1.85 THz and coupling coefficient κ from 3.46 to 4.49 THz2, while the radiative damping γ1 decreases from 11.5 to 9 THz. Such EIT-like MMs were evaluated in simulation as the refractive index sensors, which the theoretical sensitivity was calculated to 455.7 GHz/RIU (RIU, Refractive Index Unit) under 11 μm-thick analyte layer. Meanwhile, the dependence of full width at half maximum (FWHM) on analyte thickness was also studied. In experiments, it is found that the frequency shift Δf increases from 50 to 90 GHz when the oral cancer cells (HSC3) concentration improves from 1 × 105 to 7 × 105 cells/ml. The maximum experimental sensitivity approaches 900 kHz/cell ml-1 at 7 × 105 cells/ml. Additionally, the apoptosis of cancer cells under the effect of anti-cancer drug was investigated. It shows that with the increase of anti-cancer drug concentration from 1 to 15 μM and the extension of drug action duration from 24 to 72 h, the Δf changes from 140 to 70 GHz and 140-40 GHz, respectively. Besides, the corresponding FWHM also increases from 237.9 to 305.4 GHz and 237.8-337.6 GHz. The results measured by MMs biosensors and biological method exhibit a relatively good agreement, showing a great potential for cells measurement with the sensitive biosensors based on the EIT-like MMs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2018.11.014

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 375

Metadata

Authors
Yan, X., Yang, M., Zhang, Z., Liang, L., Wei, D., Wang, M., Zhang, M., Wang, T., Liu, L., Xie, J., & Yao, J.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-02
Volume
126
Pages
485-492
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2901429240
Cited by
375
References
27
FWCI
8.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The terahertz electromagnetically induced transparency-like metamaterials for sensitive biosensors in the detection of cancer cells. https://app.cochat.ai/papers/10.1016/j.bios.2018.11.014
The paper
Yan, X., Yang, M., Zhang, Z., Liang, L., Wei, D., Wang, M., Zhang, M., Wang, T., Liu, L., Xie, J., & Yao, J. (2019). The terahertz electromagnetically induced transparency-like metamaterials for sensitive biosensors in the detection of cancer cells. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2018.11.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.