Highly sensitive and chemically stable NH3 sensors based on an organic acid-sensitized cross-linked hydrogel for exhaled breath analysis

Liu, Lichao, Fei, Teng, Guan, Xin, Zhao, Hongran, Zhang, Tong·2021·Biosensors and Bioelectronics

Abstract

Due to interference by the high moisture content and complicated compositions of human exhaled breath, the trace-level detection of ammonia (NH 3) with desirable selectivity and stability is a large challenge for exhaled breath analysis. Carboxyl-sensitized hydrogels can be activated by moisture to exhibit a significant response and excellent selectivity to NH 3. However, the high activity of carboxyl groups in hydrogels is a double-edged sword, resulting in poor chemical stability during NH 3 detection. Herein, organic acids were embedded into a cross-linked poly(ethylene glycol) diacrylate (PEGDA) hydrogel via thiol-ene photochemistry to form stable hydrogels for NH 3 detection in a humid atmosphere. As a result, under high humidity conditions (80% RH), the optimal sensors exhibited superior selectivity to NH 3 among various interfering gas species, a remarkably high NH 3 response (Z a/Z g=6.20) towards 20 ppm NH 3, and an extremely low actual detection limit (50 ppb) at room temperature. Moreover, the sensors exhibited excellent chemical stability due to the moderate equilibrium water content of the hydrogel composites and acid dissociation constant of the acid groups. The moisture-activated NH 3 sensing mechanism was thoroughly investigated by complex impedance spectroscopy (CIS), quartz crystal microbalance (QCM) measurements, Fourier transform infrared (FT-IR) spectroscopy and X-ray photoelectron spectroscopy (XPS). To explore the application prospects of cross-linked hydrogel sensors for detecting NH 3 in exhaled breath, a simulated exhaled breath test was also performed.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2021.113459

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Several studies reported the direct use of hydrogel-based vapor sensors for practical applications such as smart masks, electronic skin, respiratory analysis, and wireless monitoring, demonstrating their great prospects for applications in environmental monitoring, medical health, and other fields.

    “Several studies reported the direct use of hydrogel-based vapor sensors for practical applications, such as smart masks, electronic skin, respiratory analysis, and wireless monitoring, demonstrating their great prospects for applications in environmental monitoring, medical health, and other fields”
  • The sensor exhibited a high response (6.20) to 20 ppm NH3 at room temperature, as well as a low LOD (50 ppb).

    “The sensor exhibited a high response (6.20) to 20 ppm NH3 at room temperature, as well as a low LOD (50 ppb).”
  • Zhang and her team [76] used thiol-ene photochemistry to encapsulate citric acid (CA) into crosslinked PEGDA hydrogels to prepare a highly sensitive and selective CA/PEGDA hydrogel-based NH3 gas sensor working at high humidity (80% RH).

    “Zhang and her team [76] used thiol-ene photochemistry to encapsulate citric acid (CA) into crosslinked polyethylene glycol diacrylate (PEGDA) hydrogels to prepare a highly sensitive and selective CA/PEGDA hydrogel-based NH3 gas sensor working at high humidity (80% RH).”
  • This is due to the equilibrium water content of the hydrogel composite and the moderate acid dissociation constants of the acid groups.

    “This is due to the equilibrium water content of the hydrogel composite and the moderate acid dissociation constants of the acid groups.”
  • At 80% RH, the large amount of adsorbed water enhances the activity of the carboxyl group, which causes the carboxyl group to react with a large amount of adsorbed NH3 to form ammonium salts.

    “At 80% RH, the large amount of adsorbed water enhances the activity of the carboxyl group, which causes the carboxyl group to react with a large amount of adsorbed NH3 to form ammonium salts.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Liu, L., Fei, T., Guan, X., Zhao, H., & Zhang, T.
Affiliations
Jilin University (CN)
Corresponding author
  • Zhao, Hongran
  • Zhang, Tong
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2021-11
Volume
191
Pages
113459
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3173790210
Cited by
60
References
2
Citations by year
2026: 6 · 2025: 11 · 2024: 14 · 2023: 14 · 2022: 12 · 2021: 3
FWCI
3.10
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Jilin Province People's Government Department of Education
  • Jilin Provincial Science and Technology Department
  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
ammonia gas sensor, breath analysis, crosslinked hydrogels, poly(ethylene glycol) diacrylate, chemical stability, humidity interference, trace gas detection
MeSH terms
Breath Tests, Humans, Biosensing Techniques, Spectroscopy, Fourier Transform Infrared, Hydrogels, Exhalation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review