Rapid, mass diagnosis of the coronavirus disease 2019 (COVID-19) is critical to stop the ongoing infection spread. The two standard screening methods to confirm the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are polymerase chain reaction (PCR), through the RNA of the virus, and serology by detecting antibodies produced as a response to the viral infection. However, given the detection complexity, cost and relatively long analysis times of these techniques, novel technologies are urgently needed. Here, we report an aptamer-based biosensor developed on a screen-printed carbon electrode platform for rapid, sensitive, and user-friendly detection of SARS-CoV-2. The aptasensor relies on an aptamer targeting the receptor-binding domain (RBD) in the spike protein (S-protein) of the SARS-CoV-2. The aptamer immobilization on gold nanoparticles, and the presence of S-protein in the aptamer-target complex, investigated for the first time by photo-induced force microscopy mapping between 770 and 1910 cm−1 of the electromagnetic spectrum, revealed abundant S-protein homogeneously distributed on the sensing probe. The detection of SARS-CoV-2 S-protein was achieved by electrochemical impedance spectroscopy after 40 min incubation with several analyte concentrations, yielding a limit of detection of 1.30 pM (66 pg/mL). Moreover, the aptasensor was successfully applied for the detection of a SARS-CoV-2 pseudovirus, thus suggesting it is a promising tool for the diagnosis of COVID-19.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2021.113595

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Metadata

Authors
Abrego-Martinez, J. C., Jafari, M., Chergui, S., Pavel, C., Che, D., & Siaj, M.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2022-01
Volume
195
Pages
113595
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3197877735
Cited by
159
References
7
FWCI
8.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aptamer-based electrochemical biosensor for rapid detection of SARS-CoV-2: Nanoscale electrode-aptamer-SARS-CoV-2 imaging by photo-induced force microscopy. https://app.cochat.ai/papers/10.1016/j.bios.2021.113595
The paper
Abrego-Martinez, J. C., Jafari, M., Chergui, S., Pavel, C., Che, D., & Siaj, M. (2022). Aptamer-based electrochemical biosensor for rapid detection of SARS-CoV-2: Nanoscale electrode-aptamer-SARS-CoV-2 imaging by photo-induced force microscopy. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113595

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.