CoChat

Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation: a Cochrane systematic review and meta-analysis update

Open access
Hansel, Jan, Rogers, Andrew M., Lewis, Sharon R., Cook, Tim M., Smith, Andrew F. · 2022 · British Journal of Anaesthesia
Cited by 159

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND Tracheal intubation is a commonly performed procedure that can be associated with complications and result in patient harm. Videolaryngoscopy (VL) may decrease this risk as compared with Macintosh direct laryngoscopy (DL). This review evaluates the risk and benefit profile of VL compared with DL in adults. METHODS We searched MEDLINE, Embase, CENTRAL, and Web of Science on February 27, 2021. We included RCTs comparing VL with DL in patients undergoing tracheal intubation in any setting. We separately compared outcomes according to VL design: Macintosh-style, hyperangulated, and channelled. RESULTS A total of 222 RCTs (with 26 149 participants) were included. Most studies had unclear risk of bias in at least one domain, and all were at high risk of performance and detection bias. We found that videolaryngoscopes of any design likely reduce rates of failed intubation (Macintosh-style: risk ratio [RR]=0.41; 95% confidence interval [CI], 0.26-0.65; hyperangulated: RR=0.51; 95% CI, 0.34-0.76; channelled: RR=0.43, 95% CI, 0.30-0.61; moderate-certainty evidence) with increased rates of successful intubation on first attempt and better glottic views across patient groups and settings. Hyperangulated designs are likely favourable in terms of reducing the rate of oesophageal intubation, and result in improved rates of successful intubation in individuals presenting with difficult airway features (P=0.03). We also present other patient-oriented outcomes. CONCLUSIONS In this systematic review and meta-analysis of trials of adults undergoing tracheal intubation, VL was associated with fewer failed attempts and complications such as hypoxaemia, whereas glottic views were improved. SYSTEMATIC REVIEW REGISTRATION This article is based on a Cochrane Review published in the Cochrane Database of Systematic Reviews (CDSR) 2022, Issue 4, DOI: 10.1002/14651858.CD011136.pub3 (see www.cochranelibrary.com for information). Cochrane Reviews are regularly updated as new evidence emerges and in response to feedback, and the CDSR should be consulted for the most recent version of the review.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bja.2022.05.027

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Hansel, J., Rogers, A. M., Lewis, S. R., Cook, T. M., & Smith, A. F.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2022-10
Volume
129
Issue
4
Pages
612-623
ISSN
0007-0912 (ISSN-L)
OpenAlex
W4284965831
Cited by
159
References
8
FWCI
9.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.