The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
The effect of transcutaneous vagus nerve stimulation on pain perception – An experimental study
Open accessAbstract
BACKGROUND Recent preclinical work strongly suggests that vagus nerve stimulation efficiently modulates nociception and pain processing in humans. Most recently, a medical device has offered a transcutaneous electrical stimulation of the auricular branch of the vagus nerve (t-VNS) without any surgery. OBJECTIVE Our study investigates whether t-VNS may have the potential to alter pain processing using a controlled design. METHODS Different submodalities of the somatosensory system were assessed with quantitative sensory testing (QST) including a tonic heat pain paradigm in 48 healthy volunteers. Each subject participated in two experimental sessions with active t-VNS (stimulation) or sham t-VNS (no stimulation) on different days in a randomized order (crossed-over). One session consisted of two QST measurements on the ipsi- and contralateral hand, each before and during 1 h of a continuous t-VNS on the left ear using rectangular pulses (250 μS, 25 Hz). RESULTS We found an increase of mechanical and pressure pain threshold and a reduction of mechanical pain sensitivity. Moreover, active t-VNS significantly reduced pain ratings during sustained application of painful heat for 5 min compared to sham condition. No relevant alterations of cardiac or breathing activity or clinical relevant side effects were observed during t-VNS. CONCLUSIONS Our findings of a reduced sensitivity of mechanically evoked pain and an inhibition of temporal summation of noxious tonic heat in healthy volunteers may pave the way for future studies on patients with chronic pain addressing the potential analgesic effects of t-VNS under clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional and chemical anatomy of the afferent vagal system
Berthoud, H.-R., & Neuhuber, W. L. (2000) · Autonomic Neuroscience · doi:10.1016/s1566-0702(00)00215-0 · Cited by 1,280
Nemeroff, C. B., Mayberg, H. S., Krahl, S. E., McNamara, J., Frazer, A., Henry, T. R., George, M. S., Charney, D. S., & Brannan, S. K. (2006) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301082 · Cited by 496
A review of functional neuroimaging studies of vagus nerve stimulation (VNS)
Chae, J.-H., Nahas, Z., Lomarev, M., Denslow, S., Lorberbaum, J. P., Bohning, D. E., & George, M. S. (2003) · Journal of Psychiatric Research · doi:10.1016/s0022-3956(03)00074-8 · Cited by 255
Cited by
Frangos, E., Ellrich, J., & Komisaruk, B. R. (2015) · Brain Stimulation · doi:10.1016/j.brs.2014.11.018 · Cited by 751
Self-citationThe anatomical basis for transcutaneous auricular vagus nerve stimulation
Butt, M. F., Albusoda, A., Farmer, A. D., & Aziz, Q. (2020) · Journal of Anatomy · doi:10.1111/joa.13122 · Cited by 603
Non-invasive Vagus Nerve Stimulation in Healthy Humans Reduces Sympathetic Nerve Activity
Clancy, J. A., Mary, D. A., Witte, K. K., Greenwood, J. P., Deuchars, S. A., & Deuchars, J. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.07.031 · Cited by 539
Yap, J. Y. Y., Keatch, C., Lambert, E., Woods, W., Stoddart, P. R., & Kameneva, T. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00284 · Cited by 432
Howland, R. H. (2014) · Current Behavioral Neuroscience Reports · doi:10.1007/s40473-014-0010-5 · Cited by 405
Metadata
- Authors
- Busch, V., Zeman, F., Heckel, A., Menne, F., Ellrich, J., & Eichhammer, P.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2013-03
- Volume
- 6
- Issue
- 2
- Pages
- 202-209
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2007605491
- Cited by
- 251
- References
- 3
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.