Long-Term Measurement of Impedance in Chronically Implanted Depth and Subdural Electrodes During Responsive Neurostimulation in Humans
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Long-term stability of the electrode-tissue interface may be required to maintain optimal neural recording with subdural and deep brain implants and to permit appropriate delivery of neuromodulation therapy. Although short-term changes in impedance at the electrode-tissue interface are known to occur, long-term changes in impedance have not previously been examined in detail in humans. To provide further information about short- and long-term impedance changes in chronically implanted electrodes, a dataset from 191 persons with medically intractable epilepsy participating in a trial of an investigational responsive neurostimulation device (the RNS(®) System, NeuroPace, Inc.) was reviewed. Monopolar impedance measurements were available for 391 depth and subdural leads containing a total of 1564 electrodes; measurements were available for median 802 days post-implant (range 28-1634). Although there were statistically significant short-term impedance changes, long-term impedance was stable after one year. Impedances for depth electrodes transiently increased during the third week after lead implantation and impedances for subdural electrodes increased over 12 weeks post-implant, then were stable over the subsequent long-term follow-up. Both depth and subdural electrode impedances demonstrated long-term stability, suggesting that the quality of long-term electrographic recordings (the data used to control responsive brain stimulation) can be maintained over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“A more fibrotic response would typically be acellular in nature, which would theoretically have a different impedance signature from that of the highly cellularized astrogliotic response that has been typically characterized around penetrating devices [13,14].”
BackgroundResponsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282 · cited 3×
“The time course of these impedance changes is consistent with the time course of a transient favorable effect of electrode implantation that is described in studies of neurostimulation for epilepsy in persons who are not receiving stimulation [5,49], and to the course of the clinical response to DBS in Parkinson’s dis…”
BackgroundSelf-citationClosed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793 · cited 1×
“Efforts here include responsive neurostimulation for epilepsy [5], bidirectional braine machine interface [6], and closed-loop stimulation for Parkinson’s disease [7].”
BackgroundBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708 · cited 1×
“The low levels of current used in typical impedance measurements are well below the threshold for stimulating neural activation and also correspond to charge densities within the range considered safe to avoid electrode or tissue damage [17].”
Background
Cited by
Salanova, V., Sperling, M. R., Gross, R. E., Irwin, C. P., Vollhaber, J. A., Giftakis, J. E., Fisher, R. S., & SANTÉ Study Group (2021) · Epilepsia · doi:10.1111/epi.16895 · Cited by 333
Epileptic Seizure Prediction Using Big Data and Deep Learning: Toward a Mobile System
Kiral-Kornek, I., Roy, S., Nurse, E., Mashford, B., Karoly, P., Carroll, T., Payne, D., Saha, S., Baldassano, S., O'Brien, T., et al. (2018) · EBioMedicine · doi:10.1016/j.ebiom.2017.11.032 · Cited by 303
Advances in closed-loop deep brain stimulation devices
Parastarfeizabadi, M., & Kouzani, A. Z. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0295-1 · Cited by 232
“during the first 3 months following DBS surgery [95, 96] as well as post-implantation [26, 97, 98].”
BackgroundAdvances in human intracranial electroencephalography research, guidelines and good practices
Mercier, M. R., Dubarry, A.-S., Tadel, F., Avanzini, P., Axmacher, N., Cellier, D., Vecchio, M. D., Hamilton, L. S., Hermes, D., Kahana, M. J., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119438 · Cited by 229
Ultrasoft microwire neural electrodes improve chronic tissue integration
Du, Z. J., Kolarcik, C. L., Kozai, T. D. Y., Luebben, S. D., Sapp, S. A., Zheng, X. S., Nabity, J. A., & Cui, X. T. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.010 · Cited by 209
Neurohybrid Memristive CMOS-Integrated Systems for Biosensors and Neuroprosthetics
Mikhaylov, A., Pimashkin, A., Pigareva, Y., Gerasimova, S., Gryaznov, E., Shchanikov, S., Zuev, A., Talanov, M., Lavrov, I., Demin, V., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00358 · Cited by 185
“…vivo interface systems have been studied previously in relation to neural prostheses for restoring and enhancing memory (Berger et al., 2011; Hampson et al., 2018; Song et al., 2018) also by using PC-controlled multichannel recording/stimulation closed-loop systems and special mathematical models.”
BackgroundSeizure Cycles in Focal Epilepsy
Leguia, M. G., Andrzejak, R. G., Rummel, C., Fan, J. M., Mirro, E. A., Tcheng, T. K., Rao, V. R., & Baud, M. O. (2021) · JAMA Neurology · doi:10.1001/jamaneurol.2020.5370 · Cited by 185
A forward-looking review of seizure prediction
Freestone, D. R., Karoly, P. J., & Cook, M. J. (2017) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000429 · Cited by 169
Long-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“Similarly, two epilepsy studies using subdural strips and depths electrodes from the Neuropace device estimated that the increase would last for 3 months [41] and 4 months [42].”
Rosenfeld, J. V., Wong, Y. T., Yan, E., Szlawski, J., Mohan, A., Clark, J. C., Rosa, M., & Lowery, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9e1c · Cited by 35
Phosphene perceptions and safety of chronic visual cortex stimulation in a blind subject
Niketeghad, S., Muralidharan, A., Patel, U., Dorn, J. D., Bonelli, L., Greenberg, R. J., & Pouratian, N. (2020) · Journal of Neurosurgery · doi:10.3171/2019.3.jns182774 · Cited by 33
Metadata
- Authors
- Sillay, K. A., Rutecki, P., Cicora, K., Worrell, G., Drazkowski, J., Shih, J. J., Sharan, A. D., Morrell, M. J., Williams, J., & Wingeier, B.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2013-09
- Volume
- 6
- Issue
- 5
- Pages
- 718-726
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W1981148562
- Cited by
- 134
- References
- 5
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.