A Feasibility Study of a New Method for Electrically Producing Seizures in Man: Focal Electrically Administered Seizure Therapy [FEAST]
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND Electroconvulsive therapy (ECT) remains the most effective acute treatment for severe major depression, but with significant risk of adverse cognitive effects. Unidirectional electrical stimulation with a novel electrode placement and geometry (Focal Electrically Administered Seizure Therapy (FEAST)) has been proposed as a means to initiate seizures in prefrontal cortex prior to secondary generalization. As such, it may have fewer cognitive side effects than traditional ECT. We report on its first human clinical application. METHOD Seventeen unmedicated depressed adults (5 men; 3 bipolar disorder; age 53 ± 16 years) were recruited after being referred for ECT. Open-label FEAST was administered with a modified spECTrum 5000Q device and a traditional ECT dosing regimen until patients clinically responded. Clinical and cognitive assessments were obtained at baseline, and end of course. Time to orientation recovery, a predictor of long-term amnestic effects, was assessed at each treatment. Nonresponders to FEAST were transitioned to conventional ECT. RESULTS One patient withdrew from the study after a single titration session. After the course of FEAST (median 10 sessions), there was a 46.1 ± 35.5% improvement in Hamilton Rating Scale for Depression (HRSD24) scores compared to baseline (33.1 ± 6.8, 16.8 ± 10.9; P < 0.0001). Eight of 16 patients met response criteria (50% decrease in HRSD24) and 5/16 met remission criteria (HRSD24 ≤ 10). Patients achieved full re-orientation (4 of 5 items) in 5.5 ± 6.4 min (median = 3.6), timed from when their eyes first opened after treatment. CONCLUSION In this feasibility study, FEAST produced clinically meaningful antidepressant improvement, with relatively short time to reorientation. Our preliminary work first in primates and now depressed adults demonstrates that FEAST is feasible, safe, well-tolerated and, if efficacy can be optimized, has potential to replace traditional ECT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sackeim, H. A., Prudic, J., Nobler, M. S., Fitzsimons, L., Lisanby, S. H., Payne, N., Berman, R. M., Brakemeier, E.-L., Perera, T., & Devanand, D. P. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.03.001 · Cited by 542 · cited 4×
“4 min) appeared shorter than with conventional methods (10 6 for UB RUL and 33 21 for BL ECT) [5], albeit without formal randomized comparison.”
InfluentialSelf-citationElectroconvulsive Therapy for Depression
Lisanby, S. H. (2007) · New England Journal of Medicine · doi:10.1056/nejmct075234 · Cited by 503
Self-citationTranscranial Magnetic Stimulation: Applications in Neuropsychiatry
George, M. S., Lisanby, S. H., & Sackeim, H. A. (1999) · Archives of General Psychiatry · doi:10.1001/archpsyc.56.4.300 · Cited by 496
Self-citationDecreased Regional Brain Metabolism After ECT
Nobler, M. S., Oquendo, M. A., Kegeles, L. S., Malone, K. M., Campbell, C., Sackeim, H. A., & Mann, J. J. (2001) · American Journal of Psychiatry · doi:10.1176/appi.ajp.158.2.305 · Cited by 330
Self-citationDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Self-citationElectroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Self-citationKayser, S., Bewernick, B. H., Grubert, C., Hadrysiewicz, B. L., Axmacher, N., & Schlaepfer, T. E. (2011) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2010.09.008 · Cited by 194
Cited by
Malhi, G. S., Bell, E., Bassett, D., Boyce, P., Bryant, R., Hazell, P., Hopwood, M., Lyndon, B., Mulder, R., Porter, R., et al. (2021) · Australian & New Zealand Journal of Psychiatry · doi:10.1177/0004867420979353 · Cited by 614
The neural crossroads of psychiatric illness: an emerging target for brain stimulation
Downar, J., Blumberger, D. M., & Daskalakis, Z. J. (2016) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2015.10.007 · Cited by 166
“Newer proposed montages [85] and finer titration of the current amplitude [86] may achieve still better focality over the anterior insula, or potentially the dACC.”
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Radman, T., & Lisanby, S. H. (2017) · International Review of Psychiatry · doi:10.1080/09540261.2017.1304898 · Cited by 14
“However, this amplitude of stimulation is not necessary to induce seizures, and there have been many demonstrations of low-amplitude currents inducing seizures (Liberson, 1953; Nahas et al., 2013; Figure 4.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Nahas, Z., Short, B., Burns, C., Archer, M., Schmidt, M., Prudic, J., Nobler, M. S., Devanand, D. P., Fitzsimons, L., Lisanby, S. H., Payne, N., Perera, T., George, M. S., & Sackeim, H. A.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2013-05
- Volume
- 6
- Issue
- 3
- Pages
- 403-408
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2109102677
- Cited by
- 91
- References
- 7
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.